Old 07-20-2010
this depends on the hardware you are using...
 

9 More Discussions You Might Find Interesting

1. Solaris

Hardware RAID

I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies

2. Solaris

how to hardware RAID 1 on T5120

Hi, I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1" The System did come preinstalled as it comes from sun. I did not do much on it. I booted system using boot cdrom -s gave format... (6 Replies)
Discussion started by: upengan78
6 Replies

3. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

4. UNIX for Advanced & Expert Users

check external hardware connected to linux/solaris machines

hello, I'm planning to do inventory of all our servers but this time it's more on physical. Meaning I would like to check all hardware connected to it (external only like storage, power support) including the count Would like to get perhaps its serial nr..(linux and solaris different servers... (2 Replies)
Discussion started by: lhareigh890
2 Replies

5. Solaris

how to check for hardware layered raid in solaris 10 ?

hi all, will command metastats tell whether there is hardware layered raid ? i intend to do patching and plug out one of the disks in case the one inside encountered issues. (1 Reply)
Discussion started by: Exposure
1 Replies

6. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

7. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

8. Solaris

Hardware raid patching

Dear All , we have hardware raid 1 implemented on Solaris Disks. We need to patch the Servers. Kindly let me know how to patch hardware raid implemented Servers. Thanks... Rj (7 Replies)
Discussion started by: jegaraman
7 Replies

9. Solaris

Hardware RAID using three disks

Dear All , Pl find the below command , # raidctl -l Controller: 1 Volume:c1t0d0 Disk: 0.0.0 Disk: 0.1.0 Disk: 0.3.0 # raidctl -l c1t0d0 Volume Size Stripe Status Cache RAID Sub Size ... (10 Replies)
Discussion started by: jegaraman
10 Replies
io_redirect_dsf(1M)													       io_redirect_dsf(1M)

NAME
io_redirect_dsf - redirect the persistent device special file from one device to a different device SYNOPSIS
old_hw_path new_hw_path old_dsf new_dsf DESCRIPTION
The command reassigns a persistent device special file (DSF) to a new device when both devices belong to the same class. If the new device does not already exist, before reassigning it you must create the DSF by running either or (see insf(1M) and mksf(1M)). In the first form, the command accepts as input the lun hardware paths of the device to be replaced and the new device. In the second form, the command accepts as input the persistent DSFs of the device to be replaced and the new device. Note: The device is inaccessible while the redirection is taking place. Options recognizes the following options: Specify the hardware path of the device that is being replaced. returns an error if old_hw_path is not a lun hardware path. Specify the hardware path of the new device. returns an error if new_hw_path is not a lun hardware path. Specify the device special file of the device that is being replaced. returns an error if old_dsf is not a persistent DSF. Specify the device special file of the new device. returns an error if new_dsf is not a persistent DSF. RETURN VALUE
Exit values are: Successful completion. An error condition occurred. EXAMPLES
Redirect the DSF with the hardware path at to point to the hardware path at Both disks belong to the class. Redirect the DSF to point to the device with DSF Both DSFs represent devices that belong to the class WARNINGS
You must be superuser to execute the command. SEE ALSO
insf(1M), mksf(1M), intro(7). io_redirect_dsf(1M)
All times are GMT -4. The time now is 01:41 PM.