I'm getting the below error while trying to create a SEA adapter in VIOS
Code:
$ mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1
Some error messages may contain invalid information
for the Virtual I/O Server environment.
Method error (/usr/lib/methods/cfgsea):
0514-040 Error initializing a device into the kernel.
Command did not complete.
"Run mkdev" was last subcommand run.
$
Not sure what this means.. Can someone throw some light in this
I am trying to create a SEA on a LHEA port and it gives me error
lsdev -Cc adapter:
ent0 logical host ethernet port (l-hea)
ent1 virtual I/O ethernet adapter
mkvdev -sea ent0 -vadapter ent1 -default ent1 -defaultid 199
method error (/usr/lib/methods/cfgsea):
Failed to configure SEA... (0 Replies)
Hi all,
I set up the following configuration on my system:
- An LPar with a virtual adapter, first one with a vlan id=703 and id port=13.
- The first adapter have to connect to a VIOS in which i configured an SEA.
So, the VA is set up on interface ent2, SEA on ent29 (by linking a... (0 Replies)
Hi experts, i got a 4-port Adapter card on VIOS and would like to configure 4SEA for 4 difference segment IP client's LPAR use, first SEA succeed to be configured on ent0 but once second SEA configured, first SEA fail to be connected. Any issues i need to be concerned in order to configure 4 SEA on... (8 Replies)
I am trying to install a VIOS pair with a load-sharing SEA adapter, following this recipe from Developerworks. Without load-sharing everything went fine and worked as expected, but somehow i am a bit lost and the first tries with "ha_mode=sharing" didn't work at all.
Here is the situation:
I... (6 Replies)
Hello,
Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2.
What is the common practice - should I isolate my vios... (0 Replies)
i want configure a SEA over my vios ,
i have a message error :
Method error (/usr/lib/methods/cfgsea):
Failed to configure SEA with return code 1 and SEA-specific error code 10:
Detailed info: Setting real adapter ent1 in promiscuous mode failed... (5 Replies)
hi guys
BTW pretty new to VIO
I inherited 2 I BM Power Server - blades PS701 - One is already configured using en8
# lsdev -Cc adapter | grep ent
ent0 Available Logical Host Ethernet Port (lp-hea)
ent1 Available Logical Host Ethernet Port (lp-hea)
ent2 Available 04-20... (8 Replies)
hello,
what will happen if i try to move sea of my 1 vio server to standby( using chdev command), when sea of other vio server is already in standby mode? (1 Reply)
Hello,
I found that the packet counts given by entstat -d SEA is not the same as the total of the packet counts given by seastat -d SEA for the same interval of time.
Do anyone have an explanation for the difference. We recently got a recommendation that the throughput on an SEA should not... (5 Replies)
Discussion started by: N8R
5 Replies
LEARN ABOUT LINUX
irsend
IRSEND(1) User Commands IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.9.0-pre1 October 2010 IRSEND(1)