Sponsored Content
Operating Systems Solaris Add new disk to Sun StorEdge 3310 RAID Post 302429735 by jamie_collins on Tuesday 15th of June 2010 10:47:32 AM
Old 06-15-2010
Add new disk to Sun StorEdge 3310 RAID

HI guys.
Bit of a noob so bear with me.

I have 2 new disks I want to add to my StorEdge 3310 but am getting lost in the steps. We have another 3310 (JBOD) that I was able to plug the disks into and they instantly showed up. Did a few minor commands after (drvconfig, devfsadm etc..) and I was good to partition the slices...

On our 3310 (RAID) I plugged them in and its not seeing them:

Code:
 
# format
Searching for disks...done
 
 
AVAILABLE DISK SELECTIONS:
       0. c1t0d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
          /pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w21000004cfd967a7,0
       1. c1t1d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
          /pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w21000004cfd964d1,0
       2. c2t0d0 <SUN-StorEdge3310-0325 cyl 35424 alt 2 hd 127 sec 127>
          /pci@8,600000/pci@1/scsi@4/sd@0,0

What steps do I need to perform to allow the server to see the 2 new added disks. (SEAGATES)

Thanks
 

9 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

sun storedge

I just installed sun storedge 3310 connected to a sunfire 280R with a total siz of 680GB and now am trying to create filesystems. issue format command and created my partitions, the largest size of the partition is 170GB. but I try to create new filesystems by using newfs like newfs... (3 Replies)
Discussion started by: hassan2
3 Replies

2. Solaris

Add new hard disk to sun sparc server?

A sparc server has a new SCSI hard disk added and labeled by the engineer, but they need to be formatted identically to an existing disk (c4t0d0). You decide to script the process and run from the command line without interaction. I know that the following command line must be achieve this. #... (3 Replies)
Discussion started by: kingsan
3 Replies

3. UNIX for Advanced & Expert Users

Help: Sun Disk partitioning for Sun V240 & StorEdge 3300

Dear Sun gurus, I have Sun Fire V240 server with its StorEdge 3300 disk-array. Following are its disks appeared in format command. I have prepared its partitions thru format and metainit & metattach (may be i have made wrong steps, causing the errors below because I have done thru some document... (1 Reply)
Discussion started by: shafeeq
1 Replies

4. UNIX for Dummies Questions & Answers

Sun - RAID

From what I have been finding on the net is that most all Sun RAID setups are software? Is it really that uncommon for Sun servers to have hardware RAID? (6 Replies)
Discussion started by: kingdbag
6 Replies

5. Solaris

Using Enterprise 4500 with storedge D100 and storedge A5200

Sorry if this seems trivial. i have been given a task at work to configure a sun processing server "enterprise 4500" so it can work with the a storage server "storedge A5200" and "storedge D1000" the truth is i have never worked on a sun server before. i need a guideline (step by step) as to... (5 Replies)
Discussion started by: lawalidowu
5 Replies

6. Solaris

storEDGE A5000 disk Array

Do you know how do I make my solaris 8 detect the storEDGE A5000?. I have problem making it recognise, without that I cannot install VxVM. Any ideas? (7 Replies)
Discussion started by: calsum
7 Replies

7. Filesystems, Disks and Memory

Poor read performance on sun storedge a1000

Hello, i have a a1000 connected to an e6500. There's a raid 10 (12 disks) on the a1000. If i do a dd if=/dev/zero of=/mnt/1 bs=1024k count=1000 and then look at iostat it tells me there's a kw/s of 25000. But if i do a dd of=/dev/zero if=/mnt/1 bs=1024k count=1000 then i see only a... (1 Reply)
Discussion started by: mbrenner
1 Replies

8. Solaris

Move disks to different StorEdge, keeping RAID

Hi. I need to move a 5 disk RAID5 array from a SE3310 box to a different SE3310 array. After installing the disks in the "new" StorEdge device, I "would like" ;) to be able have access to the data which is on the RAID. Essentially, the quesion is, how can this be done? :confused: I checked... (5 Replies)
Discussion started by: alexs77
5 Replies

9. Solaris

Hardware RAID not recognize the new disk [Sun T6320]

We have hardware RAID configured on Sun-Blade-T6320 and one of the disk got failed. Hence we replaced the failed disk. But the hot swapped disk not recognized by RAID. Kindly help on fixing this issue. We have 2 LDOM configured on this server and this server running on single disk. #... (8 Replies)
Discussion started by: rock123
8 Replies
fp(7d)								      Devices								    fp(7d)

NAME
fp - Sun Fibre Channel port driver DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter port management and other capabilities through well-defined fibre channel adapter driver interfaces. The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri- vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in LIRP and LILP stages of loop initialization. CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties: mpxio-disable Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no" activates I/O multipathing, while mpxio-disable="yes" disables the feature. Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4: name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0 mpxio-disable="yes"; manual_configuration_only Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con- figuration of devices. FILES
/kernel/drv/fp 32-bit ELF kernel driver (x86) /kernel/drv/amd64/fp 64-bit ELF kernel driver (x86) /kernel/drv/sparcv9/fp 64-bit ELF kernel driver (SPARC) /kernel/drv/fp.conf fp driver configuration file. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |mpxio-disable |Unstable | +-----------------------------+-----------------------------+ |manual_configuration_only |Obsolete | +-----------------------------+-----------------------------+ |Availability |SUNWfctl | +-----------------------------+-----------------------------+ SEE ALSO
cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D) Writing Device Drivers Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994 Fibre Channel Generic Services (FC-GS-2) Project 1134-D Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996 Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996 SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996 SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996 SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998 Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998 SunOS 5.10 2 Dec 2004 fp(7d)
All times are GMT -4. The time now is 11:10 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy