05-25-2010
I did manage to get the console to respond by hitting Ctrl Q.
10 More Discussions You Might Find Interesting
1. HP-UX
hi,
is it possible to have a console access on a HP UX system without Web Console ?
If yes, how ???
Many thanks in advance.
:D (3 Replies)
Discussion started by: liliput
3 Replies
2. HP-UX
Hi, hope someone could help me here:
Our root account was disabled on our production server this morning and usually we would login at the console to re-enable the account. However we are unable to get a login prompt at the console. The console displays the 8 options along the bottom and a... (2 Replies)
Discussion started by: AaronC
2 Replies
3. HP-UX
Hi friend,
I'm facing a problem to access the console and telnet to the HP ux 11 server due to the system file is full. How to access this server via single mode and how to mount the folder / and folder /var?
thanks.
vestro (1 Reply)
Discussion started by: vestro
1 Replies
4. Solaris
Hi guys,
My current set up is I have a Laptop running redhat linux.
This acts as an SSH server, and i use it to console into the LOM-A port on my Sunfire V100 using minicom. The idea is that I can remotely access and test things out.
This works great, but I've just bought another V100 server... (15 Replies)
Discussion started by: Stin
15 Replies
5. Solaris
Hi :
I have a e450 sun server that I just started up and I connect my laptop to the serial connection using a null modem cable and it just does not connect.
I use hyperterminal, I dont connect a keyboard to the sun machine?
Any ideas?
Thanks a lot
Al (3 Replies)
Discussion started by: alanj4
3 Replies
6. Solaris
Hello Folks,
I am having trouble to login to rsc or serial console of V890.
The rsc2.2.3 has been configured with required parameters, resetrs and even rebooted. When serial port is connected to laptop, The hyper terminal does not get the console or POSt messages when the server is rebooting... (8 Replies)
Discussion started by: defflepord
8 Replies
7. Shell Programming and Scripting
hi,
how to access console of a switch having rj45 on switch side to db 9 female on pc side console cable which needs to be connected to one console server having rj11 on its side and db 9 female on other end.i.e. on switch side,console cable has rj45 and db 9 pin female connector on other side of... (1 Reply)
Discussion started by: pankajd
1 Replies
8. Solaris
Hi Guys,
I am working on the e25k server.
There is 4 domain configured
Once domain is down
So I tried to access the console for the problem domain.
using console -d B
but its showing following error message.
bash-2.05$ console -d B
Domain administration permissions... (3 Replies)
Discussion started by: arumsun
3 Replies
9. Solaris
When trying to connect to console, I am getting the below error.
plathwsvcd: Another instance is running.
plathwsvcd: Another instance is running.
plathwsvcd: Another instance is running.
plathwsvcd: Another instance is running.
INIT: Id "plhw" respawning too fast: disabled for 5 minutes
... (3 Replies)
Discussion started by: aksijain
3 Replies
10. Solaris
Here is issue...
bash-3.00# svcs system/webconsole:console
STATE STIME FMRI
maintenance 1:15:54 svc:/system/webconsole:console
bash-3.00# svcadm clear svc:/system/webconsole:console
bash-3.00# svcs -a |grep /system/webconsole
offline* 1:20:44... (0 Replies)
Discussion started by: lingeshwaran
0 Replies
LEARN ABOUT OPENSOLARIS
sulogin
sulogin(1M) System Administration Commands sulogin(1M)
NAME
sulogin - access single-user mode
SYNOPSIS
sulogin
DESCRIPTION
The sulogin utility is automatically invoked by init when the system is first started. It prompts the user to type a user name and password
to enter system maintenance mode (single-user mode) or to type EOF (typically CTRL-D) for normal startup (multi-user mode). The user should
never directly invoke sulogin. The user must have the solaris.system.maintenance authorization.
The sulogin utility can prompt the user to enter the root password on a variable number of serial console devices, in addition to the tra-
ditional console device. See consadm(1M) and msglog(7D) for a description of how to configure a serial device to display the single-user
login prompt.
FILES
/etc/default/sulogin
Default value can be set for the following flag:
PASSREQ
Determines if login requires a password. Default is PASSREQ=YES.
/etc/default/login
Default value can be set for the following flag:
SLEEPTIME
If present, sets the number of seconds to wait before login failure is printed to the screen and another login attempt is allowed.
Default is 4 seconds. Minimum is 0 seconds. Maximum is 5 seconds.
Both su(1M) and login(1) are affected by the value of SLEEPTIME.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Availability |SUNWcsr |
+-----------------------------+-----------------------------+
SEE ALSO
auths(1), login(1), consadm(1M), init(1M), su(1M), attributes(5), msglog(7D)
NOTES
By default, the root user has all authorizations.
Granting the solaris.system.maintenance authorization to the Console User Rights Profile may have an undesirable side effect of granting
the currently logged in user maintenance mode access. The solaris.system.maintenance authorization should be directly granted to appropri-
ate users rather than through the Console User Rights Profile.
SunOS 5.11 21 Aug 2008 sulogin(1M)