Hi Everyone
I am building some A Class HP boxes as web proxy servers, have just installed HP-UX 11.00 and am starting to configure one according to our standard build policy.
However on the A Class I just happened to place the software depot this error message keeps popping up every 2 mins:
... (1 Reply)
I have written the following program. The function of this prog is to read data from a file(source.c) and write into another file(dest.c) using pipes. I have just written a line in the source file.Im able to compile and run the program without errors. But the data is not written onto the other... (2 Replies)
hi all,
this is how my scrip looks like
#!/bin/sh
bindir='/opt/apps/script/bin'
datadir='/opt/apps/script/data'
dir='/opt/apps/script'
while : ; do
ls -1rt /opt/apps/script/data/check.txt*|tail -1 > /dev/null 2>&1
if ;then
chmod +rwx $bindir/dummy2.sh
... (8 Replies)
Hi all,
I tried the following command
$ find / -name xyx | ls -l
so logically it should show the listing of directory xyz , assuming there's only one instance of xyz . But the above command shows the listing of current directory instead.
I got the desired result using it in the... (4 Replies)
Hello Everybody,
thanks in advance for spending some time in my problem.
My problem is this:
I want to call a java-Programm out of my shell skript, check if die return code is right, and split the output to the normal output and into a file.
The following code doesn't work right, because in... (2 Replies)
I want to have a message send & receive through 2 half-duplex pipes
Flow of data
top half pipe
stdin--->parent(client) fd1--->pipe1-->child(server) fd1
bottom half pipe
child(server) fd2---->pipe2--->parent(client) fd2--->stdout
I need to have boundary structed message... (1 Reply)
Hi!
I'm having problems with pipes... I need comunnications with childs processes and parents, but only one child can comunnicate with parent (first child), others childs can't.
A brief of code:
if(pipe(client1r)<0){
perror("pipe");
}
... (1 Reply)
1. The problem statement, all variables and given/known data:
My problem is an infinite loop when i press any other key other then Y or y in the while loop. what i want it to do is return to the normal script outside of it if pressing N or n or keep asking the same question if its any other... (4 Replies)
Discussion started by: Ren_kun
4 Replies
LEARN ABOUT DEBIAN
irsend
IRSEND(1) User Commands IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.