Sponsored Content
Operating Systems Solaris Sun T5120 hardware RAID question Post 302402640 by soliberus on Wednesday 10th of March 2010 09:07:25 AM
Old 03-10-2010
A-ha, thanks for that.

Don't know why I didn't think of the raidctl command...d'oh!!!
 

9 More Discussions You Might Find Interesting

1. Solaris

how to hardware RAID 1 on T5120

Hi, I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1" The System did come preinstalled as it comes from sun. I did not do much on it. I booted system using boot cdrom -s gave format... (6 Replies)
Discussion started by: upengan78
6 Replies

2. Solaris

How to destroy hardware raid on T5120

Hi, I have problem creating hardware raid on T5120 with 4 disks. After the hardware raid 1 created, then I used the raidctl -l c1t0d0 and raidctl -l c1t2d0 the output of volume c1t0d0 contain disk 0.0.0 0.1.0, also the volume c1t2d0 contain disk 0.0.0 0.1.0 and should be 0.2.0 0.3.0 so I... (15 Replies)
Discussion started by: netlink
15 Replies

3. Solaris

Small issue with Sun Sparc Enterprise T5120

Good Day, We have bought Sun Sparc Enterprise T5120 with pre-installed Solaris 10 Sparc But i need on this server Solaris 9. I have inserted in to DVD-rom (USB DVD-rom) with Solaris 9 for Sparc. Then log into shell and type: reboot -- cdrom. System rebooted and i have this message: ... (3 Replies)
Discussion started by: A.Shalin
3 Replies

4. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

5. Hardware

Hardware RAID on Sun T2000 Server

Hi All I have a Sun T2000 server. Couple of years ago I had configured and mirrored the boot drive with an other drive using hardware RAID 1 using raidctl command. Following is the hardware RAID output. root@oracledatabaseserver / $ raidctl RAID Volume RAID RAID Disk... (0 Replies)
Discussion started by: Tirmazi
0 Replies

6. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

7. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

8. Solaris

Sun V240 Raid Question

Hi All, I'm new to this site. I have a few question since I'm in the process how to to repair my raid on Sun V240 Server. 1. How can we create RAID in Sun Sparc v240? 2. What utility can help people create RAID in Sun Sparc v240? 3. Do we need any special software to create the... (12 Replies)
Discussion started by: angkor
12 Replies

9. Solaris

Hardware RAID not recognize the new disk [Sun T6320]

We have hardware RAID configured on Sun-Blade-T6320 and one of the disk got failed. Hence we replaced the failed disk. But the hot swapped disk not recognized by RAID. Kindly help on fixing this issue. We have 2 LDOM configured on this server and this server running on single disk. #... (8 Replies)
Discussion started by: rock123
8 Replies
ARCMSR(4)						   BSD Kernel Interfaces Manual 						 ARCMSR(4)

NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller SYNOPSIS
arcmsr* at pci? dev ? function ? DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation: - ARC-1110 PCI-X 4 Port SATA RAID Controller - ARC-1110ML PCI-X 4 Port SATA RAID Controller - ARC-1120 PCI-X 8 Port SATA RAID Controller - ARC-1120ML PCI-X 8 Port SATA RAID Controller - ARC-1130 PCI-X 12 Port SATA RAID Controller - ARC-1130ML PCI-X 12 Port SATA RAID Controller - ARC-1160 PCI-X 16 Port SATA RAID Controller - ARC-1160ML PCI-X 16 Port SATA RAID Controller - ARC-1170 PCI-X 24 Port SATA RAID Controller - ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller - ARC-1202 PCI Express 2 Port SATA RAID Controller - ARC-1210 PCI Express 4 Port SATA RAID Controller - ARC-1220 PCI Express 8 Port SATA RAID Controller - ARC-1230 PCI Express 12 Port SATA RAID Controller - ARC-1230ML PCI Express 12 Port SATA RAID Controller - ARC-1231ML PCI Express 12 Port SATA RAID Controller - ARC-1260 PCI Express 16 Port SATA RAID Controller - ARC-1260ML PCI Express 16 Port SATA RAID Controller - ARC-1261ML PCI Express 16 Port SATA RAID Controller - ARC-1280 PCI Express 24 Port SATA RAID Controller - ARC-1280ML PCI Express 24 Port SATA RAID Controller - ARC-1680 PCI Express 8 Port SAS RAID Controller - ARC-1680LP PCI Express 8 Port SAS RAID Controller - ARC-1680i PCI Express 8 Port SAS RAID Controller - ARC-1680x PCI Express 8 Port SAS RAID Controller - ARC-1681 PCI-X 8 Port SAS RAID Controller These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives. arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands. Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8). When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol- lowing command (once the initialization is finished): $ scsictl scsibus0 scan any any The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the bioctl(8) command. EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens. SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8) HISTORY
The arcmsr driver first appeared in NetBSD 5.0. AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines. BSD
March 3, 2008 BSD
All times are GMT -4. The time now is 06:25 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.