02-24-2010
sun v240 performance
Hi,
we are having one sun v240 server, now this server is performing very slow,
checked using top, iostat and vmstat commands, output is looking normal, but the performance is very slow and generating more traffic in network,
how can we resolve this.
Regards
RJS
9 More Discussions You Might Find Interesting
1. Solaris
Guys where can i find values to add in /etc/system to make sun solaris 10 working better ? im sure there is alot of values but i dont know from where i can find them if you know any please send direct and if you know another sites send links to it, thanks so much. (5 Replies)
Discussion started by: XP_2600
5 Replies
2. UNIX for Advanced & Expert Users
Dear Sun gurus,
I have Sun Fire V240 server with its StorEdge 3300 disk-array. Following are its disks appeared in format command. I have prepared its partitions thru format and metainit & metattach (may be i have made wrong steps, causing the errors below because I have done thru some document... (1 Reply)
Discussion started by: shafeeq
1 Replies
3. Solaris
Hello All.
I have Sun T1000 server with Solaris 10.
On T1000 installed EMC smarts, application for monitoring network devices via SNMP + SNMP.
So, Smarts has own DB (contains object - devices and relationships), file takes 30 mb, now, all queries to DB works very slow, so Smarts works too slow,... (5 Replies)
Discussion started by: hemulll
5 Replies
4. Filesystems, Disks and Memory
Hello,
i have a a1000 connected to an e6500. There's a raid 10 (12 disks) on the a1000.
If i do a
dd if=/dev/zero of=/mnt/1 bs=1024k count=1000
and then look at iostat it tells me there's a kw/s of 25000.
But if i do a
dd of=/dev/zero if=/mnt/1 bs=1024k count=1000
then i see only a... (1 Reply)
Discussion started by: mbrenner
1 Replies
5. Solaris
Hi,
I want to know if there is a command available for obtaining the BIOS Serial Number on a Sun Fire V240 machine? Or is it a known issue that it cannot be obtained through any command?
Thanks,
Vineet (4 Replies)
Discussion started by: vineetd
4 Replies
6. Solaris
hallo anybody know how to set alom mail alerty server with yahoomail ?
thank u?where i can find mail server address for yahoomail?thank (1 Reply)
Discussion started by: yanto85
1 Replies
7. Solaris
I have a sun fire v240 server.
The output of prtdiag -v shows a failed fan.
There are 3 fans for cooling system board.
There is 1 fan for each of the powersupply (There are 2 powersupplies)
From the below output how do i know which fan is bad and whats its location... (3 Replies)
Discussion started by: Tirmazi
3 Replies
8. Solaris
Hi All, I'm new to this site. I have a few question since I'm in the process how to to repair my raid on Sun V240 Server.
1. How can we create RAID in Sun Sparc v240?
2. What utility can help people create RAID in Sun Sparc v240?
3. Do we need any special software to create the... (12 Replies)
Discussion started by: angkor
12 Replies
9. Solaris
Hi
If you had a choice of processor for a general purpose web server, either:
A. T1, 8-core. (in a T1000, 8GB, 72GB SAS x 2)
or
B. Dual 1.6GHZ USIIIi (in a Sun Blade 2500 Silver Workstation, 4GB, 146GB SCSI)
Would A be significantly better than B?
Even on single-threaded tasks?
I... (0 Replies)
Discussion started by: edik
0 Replies
IOSTAT(1) General Commands Manual IOSTAT(1)
NAME
iostat - report I/O statistics
SYNOPSIS
iostat [ drives ] [ interval [ count ] ]
DESCRIPTION
Iostat iteratively reports the number of characters read and written to terminals per second, and, for each disk, the number of transfers
per second, kilobytes transferred per second, and the milliseconds per average seek. It also gives the percentage of time the system has
spent in user mode, in user mode running low priority (niced) processes, in system mode, and idling.
To compute this information, for each disk, seeks and data transfer completions and number of words transferred are counted; for terminals
collectively, the number of input and output characters are counted. Also, each sixtieth of a second, the state of each disk is examined
and a tally is made if the disk is active. From these numbers and given the transfer rates of the devices it is possible to determine
average seek times for each device.
The optional interval argument causes iostat to report once each interval seconds. The first report is for all time since a reboot and
each subsequent report is for the last interval only.
The optional count argument restricts the number of reports.
If more than 4 disk drives are configured in the system, iostat displays only the first 4 drives, with priority given to Massbus disk
drives (i.e. if both Unibus and Massbus drives are present and the total number of drives exceeds 4, then some number of Unibus drives will
not be displayed in favor of the Massbus drives). To force iostat to display specific drives, their names may be supplied on the command
line.
FILES
/dev/kmem
/vmunix
SEE ALSO
vmstat(1)
4th Berkeley Distribution April 29, 1985 IOSTAT(1)