Old 01-28-2010
I think what your looking for is:
Code:
/usr/sbin/ndd -set /dev/ce0 adv_1000fdx_cap 1

But, like others have mentioned, you really should be set to auto-negotiate on both the switch and nic for gigabit

Code:
/usr/sbin/ndd -set /dev/bge0 adv_autoneg_cap 1

Keep in mind you need to create an /etc/rc2.d or /etc/rc3.d file to have changes carry across reboots (besides adv_autoneg_cap)
 

10 More Discussions You Might Find Interesting

1. Solaris

Sun v440/v880 network adapter teaming

Is it possible to team two network adapters for fault tolerance in a Sun v440 or v880 Solaris 8 box? If so how would I go about doing so? (1 Reply)
Discussion started by: ghuber
1 Replies

2. Solaris

Sun Fire V440 and Patch 109147-39

Got an curious issue. I applied 109147-39 to, oh 15 or so various systems all running Jumpstarted Solaris 8. When I hit the first two V440s, they both failed with Return code 139. All non shell commands segfaulted from then on. The patch modified mainly the linker libraries and commands. ... (2 Replies)
Discussion started by: BOFH
2 Replies

3. Solaris

Sun Fire v440 keeps shutting down

Hello, I hope you can help me. I am new to Sun servers and we have a Sun Fire v440 server in which one power supply failed, we are waiting for new one. But now our server is shutting down constantly. Is there any setting with which we can prevent this behaviour? (1 Reply)
Discussion started by: Tibor
1 Replies

4. Solaris

Sun Fire v440 hardware problem (can't get ok>)

First of all it's shut down 60 second after power on and write on console : SC Alert: Correct SCC not replaced - shutting managed system down! This is cured by moving out battery from ALOM card. Now server start to loop during the testing. That's on the console: >@(#) Sun Fire V440,Netra... (14 Replies)
Discussion started by: Alisher
14 Replies

5. Solaris

error messages in Sun Fire V440

Hello, I am seeing error messages in V440 (OS = solaris 8). I have copied here : The system does not reboot constantly and it is up for last 67 days. One more interesting thing I found, I see errors start appearing at 4:52AM last until 6am and again start at 16:52am on same day.. I... (5 Replies)
Discussion started by: upengan78
5 Replies

6. Solaris

Sun v440 Drive in Slot 1 not listed but its active

I have a Sun SunFire v440 server with a hard drive in each slow. When I run "iostat -En", "format", and "cfgadm -al", 3 of the drives show up, but the one in Slot 1( which should be c1t1d0 ) is nowhere to be found. However, when I go to the rack its in an watch the activity lights, it seems... (2 Replies)
Discussion started by: the.gooch
2 Replies

7. Solaris

Firmware password Solaris Sun Fire v440

Hi: I bougth an used Sun Fire v440, and It have a firmware password. When I turn on the server, it ask for firmware password. (I don 't know what is the correct password). I can access to SC, but when I want to access to OBP, Firmware Password appears again. I remove the battery for two hours,... (1 Reply)
Discussion started by: mguazzardo
1 Replies

8. Solaris

Sun Fire v440 Over heat Problem.

Dear Team, I need some expert advice to my problem. We have a Sun Fire v440 in our customer Place. Server is working fine and no hardware deviations are found except one problem that processors generating too much heat. I have verified and found that the room temperature was 26-27 degree.... (5 Replies)
Discussion started by: sudhansu
5 Replies

9. Solaris

Sun-Fire V440 boot disk issue

Hi, I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken. Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies

10. Solaris

Removing a disk from SUN Fire V440 running Solaris 8

Hi, I have a SUN Fire V440 server running Solaris 8. One of the 4 disks do not appear when issued the format command. The "ready to remove" LED is not on either. Metastat command warns that this disk "Needs maintenace". Can I just shutdown and power off the machine and then insert an... (5 Replies)
Discussion started by: Echo68
5 Replies
bge(7D) 																   bge(7D)

NAME
bge - SUNW,bge Gigabit Ethernet driver for Broadcom BCM57xx SYNOPSIS
/dev/bge* The bge Gigabit Ethernet driver is a multi-threaded, loadable, clonable, GLD-based STREAMS driver supporting the Data Link Provider Inter- face, dlpi(7P), on Broadcom BCM57xx (BCM5700/5701/5703/5704/5705/5705M/5714/5721/5751/5751M/5782/5788 on ) Gigabit Ethernet controllers fitted to the system motherboard. With the exception of BCM5700/BCM5701/BCM5704S, these devices incorporate both MAC and PHY functions and provide three-speed (copper) Ethernet operation on the RJ-45 connectors. (BCM5700/BCM5701/BCM5704S do not have a PHY integrated into the MAC chipset.) The bge driver functions include controller initialization, frame transmit and receive, promiscuous and multicast support, and error recov- ery and reporting. The bge driver and hardware support auto-negotiation, a protocol specified by the 1000 Base-T standard. Auto-negotiation allows each device to advertise its capabilities and discover those of its peer (link partner). The highest common denominator supported by both link partners is automatically selected, yielding the greatest available throughput, while requiring no manual configuration. The bge driver also allows you to configure the advertised capabilities to less than the maximum (where the full speed of the interface is not required), or to force a specific mode of operation, irrespective of the link partner's advertised capabilities. APPLICATION PROGRAMMING INTERFACE
The cloning character-special device, /dev/bge, is used to access all BCM57xx devices ( (BCM5700/5701/5703/5704, 5705/5714/5721/5751/5751M/5782 on ) fitted to the system motherboard. The bge driver is managed by the dladm(1M) command line utility, which allows VLANs to be defined on top of bge instances and for bge instances to be aggregated. See dladm(1M) for more details. You must send an explicit DL_ATTACH_REQ message to associate the opened stream with a particular device (PPA). The PPA ID is interpreted as an unsigned integer data type and indicates the corresponding device instance (unit) number. The driver returns an error (DL_ERROR_ACK) if the PPA field value does not correspond to a valid device instance number for the system. The device is initialized on first attach and de- initialized (stopped) at last detach. The values returned by the driver in the DL_INFO_ACK primitive in response to a DL_INFO_REQ are: o Maximum SDU is 1500 (ETHERMTU - defined in <sys/ethernet.h>). o Minimum SDU is 0. o DLSAP address length is 8. o MAC type is DL_ETHER. o SAP length value is -2, meaning the physical address component is followed immediately by a 2-byte SAP component within the DLSAP address. o Broadcast address value is the Ethernet/IEEE broadcast address (FF:FF:FF:FF:FF:FF). Once in the DL_ATTACHED state, you must send a DL_BIND_REQ to associate a particular Service Access Point (SAP) with the stream. CONFIGURATION
By default, the bge driver performs auto-negotiation to select the link speed and mode. Link speed and mode can be any one of the follow- ing, (as described in the IEEE803.2 standard): o 1000 Mbps, full-duplex o 1000 Mbps, half-duplex o 100 Mbps, full-duplex o 100 Mbps, half-duplex o 10 Mbps, full-duplex o 10 Mbps, half-duplex The auto-negotiation protocol automatically selects: o Speed (1000 Mbps, 100 Mbps, or 10 Mbps) o Operation mode (full-duplex or half-duplex) as the highest common denominator supported by both link partners. Because the bge device supports all modes, the effect is to select the highest throughput mode supported by the other device. Alternatively, you can set the capabilities advertised by the bge device using ndd(1M). The driver supports a number of parameters whose names begin with adv_ (see below). Each of these parameters contains a boolean value that determines whether the device advertises that mode of operation. The adv_pause_cap indicates whether half/full duplex pause is advertised to link partner. And the adv_asym_pause_cap can be set to advertise to link partner that asymmetric pause is desired. In addition, bge uses adv_100T4_cap to advertise its 100T4 capabil- ity. The adv_autoneg_cap parameter controls whether autonegotiation is performed. If adv_autoneg_cap is set to 0, the driver forces the mode of operation selected by the first non-zero parameter in priority order as listed below: (highest priority/greatest throughput) adv_1000fdx_cap 1000Mbps full duplex adv_1000hdx_cap 1000Mpbs half duplex adv_100fdx_cap 100Mpbs full duplex adv_100hdx_cap 100Mpbs half duplex adv_10fdx_cap 10Mpbs full duplex adv_10hdx_cap 10Mpbs half duplex (lowest priority/least throughput) For example, to prevent the device 'bge2' from advertising gigabit capabilities, enter (as super-user): # ndd -set /dev/bge2 adv_1000hdx_cap 0 # ndd -set /dev/bge2 adv_1000fdx_cap 0 All capabilities default to enabled. Note that changing any capability parameter causes the link to go down while the link partners renego- tiate the link speed/duplex using the newly changed capabilities. The current settings of the parameters may be found using ndd -get. In addition, the driver exports the current state, speed, duplex set- ting, and working mode of the link via ndd parameters (these are read only and may not be changed). For example, to check link state of device bge0: # ndd -get /dev/bge0 link_status 1 # ndd -get /dev/bge0 link_speed 100 # ndd -get /dev/bge0 link_duplex 2 # ndd -get /dev/bge0 link_rx_pause 1 # ndd -get /dev/bge0 link_tx_pause 1 The output above indicates that the link is up and running at 100Mbps full-duplex with its rx/tx direction pause capability. In addition, the driver exports its working mode by loop_mode. If it is set to 0, the loopback mode is disabled. /dev/bge* Character special device. /kernel/drv/sparcv9/bge SPARC bge driver binary. /kernel/drv/amd64/bge kernel module for 64-bit platform /platform/i86pc/kernel/drv/bge 32-bit bge driver binary. /platform/i86pc/kernel/drv/amd64/bge 64-bit bge driver binary. See attributes(5) for a description of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Architecture |SPARC, | +-----------------------------+-----------------------------+ dladm(1M), attributes(5), streamio(7I), dlpi(7P) Writing Device Drivers STREAMS Programming Guide Network Interfaces Programmer's Guide 23 Feb 2005 bge(7D)
All times are GMT -4. The time now is 09:30 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy