1) AIX Supports iSCSI. If FreeNAS utilizes the iSCSI protocol, than it can be used.
2) see first answer
3) check your system to see if the iscsi drivers are installed, if they are not you can install them from CD or download them from IBM's website.
Code:
lslpp -L | grep iscsi

Padow
 

10 More Discussions You Might Find Interesting

1. AIX

Restoring mksysb to vio lpar?

I have a standard template I deploy for each of my AIX servers. It's in a mksysb format which I pulled via the nim server after I originally set it up. I'm trying to restore this mksysb over the wire to a remote system. The remote system is an lpar running under vio (no HMC attached). The disk... (1 Reply)
Discussion started by: scottsl
1 Replies

2. UNIX for Dummies Questions & Answers

Unix VIO vs Dynamic LPAR

Can you have a Dynamic LPAR without VIO and if yes is there a benefit to having both? I am attempting to implement VIO and Resource pooling at my company and want to understand the limitations. Also, I have been told the managing and allocation of the Logical Volumes is a time consuming task as... (0 Replies)
Discussion started by: bombers73
0 Replies

3. AIX

LPAR and vio disk mapping

We have a frame the uses 2 vios that assign disk storage to LPAR's. We have a LPAr with multiple disk and I want to know how do I tell which vio is serving the disk. For example the LPAr has hdisk 0, 1, 2, 3 all the same size. I want to know which vio is serving hdisk0, 1. (4 Replies)
Discussion started by: daveisme
4 Replies

4. AIX

LPAR and AIX VIO Disk Mappring for Linux Clients

VIO Server is managing both AIX Clients and Linux Clients. For AIX Clients, we could do a disk mapping from slot numbers to VIO and also uname -L to determine the lparid and serial number frame its running on. From a Linux Client, How do I know which IBM frame its running on? Any command to... (4 Replies)
Discussion started by: rpangulu
4 Replies

5. AIX

LPAR - What is my VIO (hostname, IP, ...)

I am wondering if there is a command I can run from **with-in** LPAR server (server01) to find out the hostname or IP address or other parameters for VIO server in charge of server01? (1 Reply)
Discussion started by: ms1232
1 Replies

6. AIX

Possible to connect a LPAR to two different VIO's?

Just a question which may seem dumb to some out there, but then again I am not a super technie so that's my excuse. Is it possible to say provision a test AIX LPAR (has a 10gb boot lun and 20gb data) under a VIO which has connectivity to SAN Array A so it can see the disks provisioned to it,... (2 Replies)
Discussion started by: Johnny1314
2 Replies

7. AIX

A solution to the mkvg failure when adding iSCSI disks to AIX.

Previous forum threads have noted that AIX cannot use iSCSI disks because it fails when trying to add them to a volume group using mkvg. The failure is caused by AIX's use of the SCSI "WRITE AND VERIFY"(0x2e) command which some iSCSI targets do not support. We experienced the same problem using... (1 Reply)
Discussion started by: garethr
1 Replies

8. AIX

VIO server does not show new LPAR

Hi All, I've been trying to create a new LPAR for some days now but I can't get the VIO server to recognize the new LPAR. This is what I did: On HMC create new LPAR On HMC create new virtual scsi adapter for LPAR in VIO profile On HMC add new virtual scsi adapter for LPAR with DLPAR... (6 Replies)
Discussion started by: petervg
6 Replies

9. Linux

FC, iSCSI, and NAS configuration?

I am using Windows Server 2008R2 as a domain controller to 2 other servers and would like to use my Dell Powervault 770N as my NAS for data storage. I have FC that I would like to implement between the servers and the NAS (as an iSCSI target). I am brand new to this world; is this possible? I am... (2 Replies)
Discussion started by: NoviceAdmin
2 Replies

10. AIX

VIO and LPAR disk/fcs communications

:wall::wall::wall: 1. I have created an LPAR in the HMC. 2. I have allocated the storage from an Hitachi AMS2500 and assigned it to the host group. 3. I have zoned the LPAR and Storage on a Brocade 5100. (The zone sees the AMS) Next I activated the LPAR in the HMC, SMS mode for the mksysb... (3 Replies)
Discussion started by: Dallasguy7
3 Replies
ISCSI-TARGET(8) 					    BSD System Manager's Manual 					   ISCSI-TARGET(8)

NAME
iscsi-target -- service remote iSCSI requests SYNOPSIS
iscsi-target [-46DV] [-b block length] [-f configuration file] [-p port number] [-s maximum number of sessions] [-t target name] [-v verbose arg] DESCRIPTION
iscsi-target is the server for iSCSI requests from iSCSI initiators. iscsi-target listens for discovery and login requests on the required port, and responds to those requests appropriately. Options and operands available for iscsi-target: -4 iscsi-target will listen for IPv4 connections, and respond back using IPv4. This is the default address family. -6 iscsi-target will listen for IPv6 connections, and respond back using IPv6. -b blocksize Specify the underlying block size for iSCSI storage which will be served. The possible sizes are: 512, 1024, 2048, and 4096 bytes, with the default being 512 bytes. -D When this option is specified, iscsi-target will not detach itself from the controlling tty, and will not become a daemon. This can be useful for debugging purposes. -f configfile Use the named file as the configuration file. The default file can be found in /etc/iscsi/targets. See targets(5) for more informa- tion. -p port number Use the port number provided as the argument as the port on which to listen for iSCSI service requests from initiators. -s maximum number of sessions Allow the maximum number of sessions to be initiated when connecting to the target. -t filename The target name (as it appears to the iSCSI initiator) can be specified using this flag. -V iscsi-target will print the utility name and version number, and the address for bug reports, and then exit. -v argument The amount of information shown can be varied by using this command. Possible values of argument are net to show network-related information, iscsi to show iSCSI protocol-related information, scsi to show SCSI protocol information, and all to show information from all of the above arguments. FILES
/etc/iscsi/targets the list of exported storage /var/run/iscsi-target.pid the PID of the currently running iscsi-target SEE ALSO
targets(5) HISTORY
The iscsi-target utility first appeared in NetBSD 4.0. BSD