10-16-2009
[RHEL4.5] server shutdown when I unplug the ethernet cable
hi..
I unplug my eth0 lan cable.. and suddenly my system shutdown... no idea
10 More Discussions You Might Find Interesting
1. Solaris
HI all,
i still have a problem when using null modem to see the output from my server(sun ultra en 3000).
i followed the instruction from the internet, but it is not working.
1. i am using db9(5 4, 2 rows,put in laptop serial port) and db25(13 12, 2 rows,put in (A) server serial port).
2.... (3 Replies)
Discussion started by: waterbear
3 Replies
2. AIX
Hi Guys,
Please help in this...when we start HACMP services ..server is getting shutdon.
Error mesg from cluster.log.
Apr 14 08:43:27 bascop17 snmpd: NOTICE: SMUX trap: (0 0) (127.0.0.1+46302+1)
Apr 14 08:43:33 bascop17 topsvcs: (Recorded using libct_ffdc.a cv 2):::Error ID:... (1 Reply)
Discussion started by: b_manu78
1 Replies
3. IP Networking
Hi, I am trying to implement a server-client socket communication. My server and clients are in different PCs. During communications if the ethernet cable is removed from the server side it shows broken pipe due to unable to write on the socket. I want to know how to check whether the ethernet... (0 Replies)
Discussion started by: JagadishB
0 Replies
4. IP Networking
Hi,
I'm trying to communicate two servers (HP DLProliant 380 G5) via a crossover cable, but I don't get them to ping each other.
I am working in RHEL 4.
These are the steps I've performed:
1) Plugged the crossover cables in eth2.
(note: The cable is brand new. Also I built one myself... (3 Replies)
Discussion started by: jrodriguez365
3 Replies
5. UNIX for Dummies Questions & Answers
how to change ethernet cable of iscsi initiator (iscsi client) (0 Replies)
Discussion started by: pankajd
0 Replies
6. Programming
Hi,
I want to code TCP/IP client/server in linux application capable to fastly detect ethernet cable disconnection in any condition.
So I have activate SO_KEEPALIVE options and set TCP_KEEPCNT, TCP_KEEPIDLE and TCP_KEEPINTVL to 1.
When I disconnect ethernet cable I have the following... (5 Replies)
Discussion started by: jeje_clb
5 Replies
7. UNIX for Advanced & Expert Users
Hi All,
I want to shutdown the server if no one is actualy using it. Its a linux server.
I thought of sending a msg on users terminal for those who all are logged in and expecting a input from them.
If they will reply system should not get shutdown else it should not.
Can any one... (2 Replies)
Discussion started by: Sadhana
2 Replies
8. AIX
Hi,
is it possible to find out ip address of user who has shutdown or rebooted the server , I have used the command errpt -a , in that it is showing server rebooted but it is not showing ip address who has shutdown the serve, even I have used command last reboot.
Please suggest.
Regards,
... (3 Replies)
Discussion started by: manoj.solaris
3 Replies
9. AIX
Hi
In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID.
Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies
10. Solaris
show /HOST command shows that
status = OpenBoot Running
when in this state, can the power be unplugged from the server ?
we are unable to bring the status to "powered off". Even if we issue "stop /SYS" it will momentarily be in the powered off status and then go back to power on... (1 Reply)
Discussion started by: paulk93
1 Replies
LEARN ABOUT REDHAT
apcsmart
APCSMART(8) Network UPS Tools (NUT) APCSMART(8)
NAME
apcsmart - Driver for American Power Conversion Smart Protocol UPS equipment
NOTE
This man page only documents the hardware-specific features of the apcsmart driver. For information about the core driver, see nutups-
drv(8).
SUPPORTED HARDWARE
apcsmart should recognize all APC models that use a serial protocol at 2400 bps. This is primarily the Smart-UPS and Matrix-UPS lines, but
some Back-UPS Pro models are also supported.
Some older hardware may only report a handful of variables. This is usually not a bug - they just don't support anything else.
CABLING
This driver expects to see a 940-0024C cable or a clone by default. You can switch to the 940-0095B dual-mode cable support with the
cable= definition described below.
If your 940-0024C cable is broken or missing, use this diagram to build a clone:
http://www.exploits.org/nut/library/cables/940-0024C.jpg
EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5):
cable=940-0095B
Configure the serial port for the APC 940-0095B dual-mode cable.
sdtype=num
Use shutdown type num, according to this table:
0: soft shutdown or powerdown, depending on battery status
1: soft shutdown followed by powerdown
2: instant power off
3: power off with grace period
Modes 0 and 1 will power up the load when power returns. Modes 2 and 3 will keep the load turned off when the power returns.
BUGS
Some older APC UPS models return bogus data in the status register during a front panel test. This is usually detected and discarded, but
some other unexpected values have occasionally slipped through.
AUTHOR
Russell Kroll
SEE ALSO
The core driver:
nutupsdrv(8)
Internet resources:
The NUT (Network UPS Tools) home page: http://www.exploits.org/nut/
NUT mailing list archives and information: http://lists.exploits.org/
Tue Oct 22 2002 APCSMART(8)