Sponsored Content
Operating Systems Solaris Query related to device naming of SATA Post 302360254 by saagar on Thursday 8th of October 2009 12:11:05 PM
Old 10-08-2009
Query related to device naming of SATA

Friends,
Could u please clarify how does a Solaris 10 machine recognize a SATA hard disk, SATA CD/DVD drives.
Will it recognize it like a SCSI? eg.c0t0d0 or like ide ? eg.c0d0


thank u.
 

10 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

Query related to #!/bin/sh

hi All Why is #!/bin/sh being used in most of the ksh scripts......? I have seen this (#!/bin/sh) being used at the start of the script Regards Suresh (2 Replies)
Discussion started by: sureshg_sampat
2 Replies

2. Shell Programming and Scripting

sed related query

Hi I have a file which looks like this //string = "abcd"; //info //string = "*pqrs"; //add string = "#123"; //sub //string = "#1234567890" data = check(string) //string = "#1234567890" I want to modify this as string = "#987"; //mult data = check(string) How do i do that? (1 Reply)
Discussion started by: gopsman
1 Replies

3. UNIX for Dummies Questions & Answers

awk related query

hi, I have to extract a column from a file and then updated that column..?? Now i can use wak for extracting it and then how to update it.. $ awk' {print $5}' input_file Can i use sed command here piping it to the output from the awk command.. (2 Replies)
Discussion started by: abhisek.says
2 Replies

4. Shell Programming and Scripting

Print related query

i Am using the below query and printing the $8 and $9 filed.. find /A/B/C/{1,3,5,7} -name "*.txt" -o -name "*.csv" -o -name "*.TXT" -o -name "*.dat" |xargs ls -ltr |awk '{print $8 ,$9}' > result.xls this give me the rsult like below.. 2008/home/ADMIN/om/1.txt 2008/home/ADMIN/om/hi.txt ... (1 Reply)
Discussion started by: sapan123
1 Replies

5. Shell Programming and Scripting

query related to if

wht does below statement mean? if wht does dis -d option do?? TIA. (1 Reply)
Discussion started by: sainathdeg
1 Replies

6. Solaris

A query on Disk naming conventions in Solaris.

These are findings by me with my little experience with Solaris 10. Please correct me if wrong.. In x86 systems with ide hard disk: c= controller d=disk s=slice 1.Here controller c0 means the primary ide controller ide0. controller c1 means the secondary ide controller ide1. ... (5 Replies)
Discussion started by: saagar
5 Replies

7. Shell Programming and Scripting

datetimestamp related query!

Hi all, I have put a query in a thread but didn't get any reply. Hoping to get a reply here. I have a file in that one line resembles like below... Forwarded by Deepak on 11/15/2009 10:28 AM EST ofcourse AM can be PM also... so what i need is first i need to get only... (1 Reply)
Discussion started by: smarty86
1 Replies

8. UNIX for Dummies Questions & Answers

A query related to 'ls' command

I am executing the ls command to show the contents of a folder, it shows some number in front of word total as highlighted in blue color below quotes. Can anyone please share that what it is? (2 Replies)
Discussion started by: Zaib
2 Replies

9. UNIX for Dummies Questions & Answers

query related to grep

Hi All, The result for 'grep "cert_codes" /develop/sales/appl.srce/*.4gl' command will be saved at aa.txt grep "cert_codes" /develop/sales/appl.srce/*.4gl >aa.txt But I am not sure, whether, all result stored in .txt file in case of multi-line result. Please revert back if... (2 Replies)
Discussion started by: pbankar
2 Replies

10. Emergency UNIX and Linux Support

Interfaces related query

I need to list the interfaces that uses FTP instead of SFTP on my applications that are on AIX servers. How do I get that list of IP addresses that connect to my applications via FTP? (2 Replies)
Discussion started by: ggayathri
2 Replies
ARCMSR(4)						   BSD Kernel Interfaces Manual 						 ARCMSR(4)

NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller SYNOPSIS
arcmsr* at pci? dev ? function ? DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation: - ARC-1110 PCI-X 4 Port SATA RAID Controller - ARC-1110ML PCI-X 4 Port SATA RAID Controller - ARC-1120 PCI-X 8 Port SATA RAID Controller - ARC-1120ML PCI-X 8 Port SATA RAID Controller - ARC-1130 PCI-X 12 Port SATA RAID Controller - ARC-1130ML PCI-X 12 Port SATA RAID Controller - ARC-1160 PCI-X 16 Port SATA RAID Controller - ARC-1160ML PCI-X 16 Port SATA RAID Controller - ARC-1170 PCI-X 24 Port SATA RAID Controller - ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller - ARC-1202 PCI Express 2 Port SATA RAID Controller - ARC-1210 PCI Express 4 Port SATA RAID Controller - ARC-1220 PCI Express 8 Port SATA RAID Controller - ARC-1230 PCI Express 12 Port SATA RAID Controller - ARC-1230ML PCI Express 12 Port SATA RAID Controller - ARC-1231ML PCI Express 12 Port SATA RAID Controller - ARC-1260 PCI Express 16 Port SATA RAID Controller - ARC-1260ML PCI Express 16 Port SATA RAID Controller - ARC-1261ML PCI Express 16 Port SATA RAID Controller - ARC-1280 PCI Express 24 Port SATA RAID Controller - ARC-1280ML PCI Express 24 Port SATA RAID Controller - ARC-1680 PCI Express 8 Port SAS RAID Controller - ARC-1680LP PCI Express 8 Port SAS RAID Controller - ARC-1680i PCI Express 8 Port SAS RAID Controller - ARC-1680x PCI Express 8 Port SAS RAID Controller - ARC-1681 PCI-X 8 Port SAS RAID Controller These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives. arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands. Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8). When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol- lowing command (once the initialization is finished): $ scsictl scsibus0 scan any any The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the bioctl(8) command. EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens. SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8) HISTORY
The arcmsr driver first appeared in NetBSD 5.0. AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines. BSD