Sponsored Content
Operating Systems Solaris SAN - Hard loop / prefered paths - help Post 302354454 by achenle on Friday 18th of September 2009 08:02:12 AM
Old 09-18-2009
What SAN do you see now in format? If they're really, really long device names you're probably perfectly fine already.
 

10 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

The best partitioning schem for a 250GB Sata hard drive & a 75GB SCSI hard drive

Hi I have 2 75GB SCSI hard drives and 2 250GB SATA hard drives which are using RAID Level 1 respectively. I wana have both FTP and Apache installed on them as services. I'm wondering what's the best partitioning schem? I wana use FC3 as my OS, so, I thought I can use the 75GB hard drive as the /... (0 Replies)
Discussion started by: sirbijan
0 Replies

2. Solaris

Thoughts/experiences of SAN attaching V880 to EMC SAN

Hi everyone, I wonder if I can canvas any opinions or thoughts (good or bad) on SAN attaching a SUN V880/490 to an EMC Clarion SAN? At the moment the 880 is using 12 internal FC-AL disks as a db server and seems to be doing a pretty good job. It is not I/O, CPU or Memory constrained and the... (2 Replies)
Discussion started by: si_linux
2 Replies

3. Filesystems, Disks and Memory

Multiple Paths to SAN with LVM in Linux?

I'm setting up a CentOS 5 server that will be connected to an HP EVA4000. My previous experience is with an HP VA7400 and HP-UX. In HP-UX I can add "alternate paths" to a volume group in order to have redundant paths to the SAN via dual fiber channel HBAs just by either adding them with... (3 Replies)
Discussion started by: deckard
3 Replies

4. AIX

hard disk and san

Hello everyone I got several aix boxes with aix 5.3 I got a ibm san ds4500 My question is How can I do a match between my disks on aix and the san? I try to do a match with the LUN but for example. In my san I got several 1 LUN and on one of my aix box I got this If I type lscfg... (4 Replies)
Discussion started by: lo-lp-kl
4 Replies

5. Solaris

SAN connection - configuring fibre attached hard drive

Hi All, I recently got a connection to the SAN through a fibre channel on my solaris box: #luxadm -e port /devices/pci@1d,700000/SUNW,qlc@1/fp@0,0:devctl CONNECTED #ls -l /dev/cfg lrwxrwxrwx 1 root root 48 Feb 23 12:31 c4 -> ../../devices/pci@1d,700000/SUNW,qlc@1/fp@0,0:fc I then... (2 Replies)
Discussion started by: dede
2 Replies

6. Shell Programming and Scripting

Script to check the SAN paths.

Hello All, We have a script which when run on the host gives us the status of the internal and SAN attached disks, its paths and other information. The output of which is as follows: Nm DEVICE VEND PROD LunID SYM DevID DISKGROUP SIZE N E... (3 Replies)
Discussion started by: mahive
3 Replies

7. AIX

IBM SAN TO SAN Mirroring

Has anyone tried SAN to SAN mirroring on IBM DS SAN Storage. DS5020 mentions Enhanced Remote Mirror to multi-LUN applications I wonder if Oracle High availibility can be setup using Remote Mirror option of SAN ? (1 Reply)
Discussion started by: filosophizer
1 Replies

8. UNIX Desktop Questions & Answers

Change name of files to their paths -- find loop

Dear All, I have many sub-folders but each of them have a file with same name but different data. I want to either move or copy them into a new folder but they need to have the path of where they are coming as part of their name... I have managed to find the files but dont know how to change... (2 Replies)
Discussion started by: A-V
2 Replies

9. Shell Programming and Scripting

REGEX to separate paths by whitespace and do a loop

I am trying to do in a single line to take a list of paths separated by whitespace and then loop thru all the paths that were wrote but my regex is not working, I have echo {3} | sed 's/ //g' | while read EACHFILE do ..... But for some reason is only taking always the first path that I... (7 Replies)
Discussion started by: jorgejac
7 Replies

10. Filesystems, Disks and Memory

Faster way: SAN hd to SAN hd copying

hi! i got a rhel 6.3 host that already have an xfs filesystem mounted from a SAN (let's call it SAN-1) whose size is 9TB. i will be receiving another SAN (let's call it SAN-2) storage of 15TB size. this new addition is physically on another SAN storage. SAN-1 is on a Pillar storage while the new... (6 Replies)
Discussion started by: rino19ny
6 Replies
fp(7d)								      Devices								    fp(7d)

NAME
fp - Sun Fibre Channel port driver DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter port management and other capabilities through well-defined fibre channel adapter driver interfaces. The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri- vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in LIRP and LILP stages of loop initialization. CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties: mpxio-disable Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no" activates I/O multipathing, while mpxio-disable="yes" disables the feature. Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4: name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0 mpxio-disable="yes"; manual_configuration_only Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con- figuration of devices. FILES
/kernel/drv/fp 32-bit ELF kernel driver (x86) /kernel/drv/amd64/fp 64-bit ELF kernel driver (x86) /kernel/drv/sparcv9/fp 64-bit ELF kernel driver (SPARC) /kernel/drv/fp.conf fp driver configuration file. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |mpxio-disable |Unstable | +-----------------------------+-----------------------------+ |manual_configuration_only |Obsolete | +-----------------------------+-----------------------------+ |Availability |SUNWfctl | +-----------------------------+-----------------------------+ SEE ALSO
cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D) Writing Device Drivers Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994 Fibre Channel Generic Services (FC-GS-2) Project 1134-D Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996 Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996 SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996 SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996 SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998 Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998 SunOS 5.10 2 Dec 2004 fp(7d)
All times are GMT -4. The time now is 07:24 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy