Sponsored Content
Full Discussion: Raid 0 stripe size
Operating Systems Linux Raid 0 stripe size Post 302347435 by mark54g on Tuesday 25th of August 2009 04:45:05 PM
Old 08-25-2009
the card may be doing its own read ahead and buffering for you, I am not sure enough about the firmware on the PERC card.

I know that in some cases, especially in software RAID, that a read ahead will increase performance in some cases where you were to do some linear reads and such where you read say 4MB ahead of where the target read is, as that will likely be called and you gather the data more efficiently.
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

MSR magnetic stripe card reader

Hi all I am working on MSR110 ...Can anyone plz tell me how to use the configuration commands with magnetic reader???. Please help me out as i have to develop API in C on linux platform.MSR110 is not responding to the configuration commands. Please help... Regards Mahima (0 Replies)
Discussion started by: mahima_er
0 Replies

2. UNIX for Advanced & Expert Users

Resizing veritas mirror-stripe volume

Hi, Is there are any special preocedure for extending veritas mirror-stripe volume? In my case , volume lay out looks as below v test - ENABLED ACTIVE 419430400 SELECT - fsgen pl test-01 test ENABLED ACTIVE 419454720 STRIPE 3/128 RW sd... (0 Replies)
Discussion started by: 2k7.vipin
0 Replies

3. AIX

AIX striped LV - lslv stripe width has wrong value

Hello all. I have a volume group with 8 PV's, and a logical volume striped across these 8 volumes. However, an lslv is showing: STRIPE WIDTH: 9 STRIPE SIZE: 64k There's really only eight disks, so how can the stripe width be 9? ODM also showed this: # odmget CuAt |... (4 Replies)
Discussion started by: Scott
4 Replies

4. Emergency UNIX and Linux Support

AIX : Create LV with poor man stripe

Hi all I have just had SAN allocate 4*30 GB of disks and had created a new scalable vg and assigned the disks to it: I used smitty to create vg and the command is: x -y'vgdata1' hdisk82 hdisk83 hdisk84 hdisk85 root@aadcxs08 / : lsvg vgdata1 VOLUME GROUP: vgdata1 VG... (4 Replies)
Discussion started by: hedkandi
4 Replies

5. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

6. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

7. Solaris

solaris volume manager- stripe?

Hello Admins.. I am going through solaris volume manager guide for RAID-0 concatenation and stripes, I do not understand the concept of stripe from following example of concatenation. There is an eample for concatenation: # metainit d25 1 1 c0t1d0s2 d25: Concat/Stripe is setup the... (5 Replies)
Discussion started by: snchaudhari2
5 Replies

8. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies

9. Shell Programming and Scripting

awk or sed or any commands to stripe data

Say i have: g_gateway domain="abc.com" to="123.123.123.123" relay="false" how do i use awk or sed or any method to get the result below: abc.com 123.123.123.123 (3 Replies)
Discussion started by: timmywong
3 Replies
nfs2_nra(5)							File Formats Manual						       nfs2_nra(5)

NAME
nfs2_nra - control the number of read-ahead operations queued by the NFS version 2 client when sequentially accessing a file VALUES
Failsafe Default Allowed values Recommended values A warning will be issued at runtime if the tunable is set to a value greater than 16 since this is beyond the tested limit. This is not a serious warning but just an information message for the administrator. DESCRIPTION
controls the number of read-ahead operations that are queued by the NFS version 2 client when sequential access to a file is discovered. These read-ahead operations increase concurrency and read throughput. Each read-ahead request is generally for 8192 bytes of file data. Who Is Expected to Change This Tunable? The distributed file system administrator should examine this value depending on network bandwidth and memory pressure on the client. Restrictions on Changing The tunable is dynamic; tuning will take effect immediately on the running system. When Should the Value of This Tunable Be Raised? If the network is very high bandwidth and the client and server have sufficient resources, increase this value to more effectively utilize the available network bandwidth, the client resources, and the server resources. What Are the Side Effects of Raising the Value? Tuning incorrectly based on network bandwidth can cause performance problems. When Should the Value of This Tunable Be Lowered? In a very low bandwidth network, you might want to decrease this value so the NFS client does not overload the network. What Are the Side Effects of Lowering the Value? Tuning incorrectly based on network bandwidth can cause performance problems. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Sun Microsystems, Inc. SEE ALSO
kctune(1M), sam(1M), gettune(2), settune(2), nfs3_nra(5), nfs4_nra(5), values(5). Tunable Kernel Parameters nfs2_nra(5)
All times are GMT -4. The time now is 04:05 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy