If you're still looking for help, can you show what the output of a simple 'metastat' would be and then highlight (possibly in a different color) what you really want?
 

8 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

how do I negate a sed match

I have a text file that has links in it. I can write a match for sed to replace the link with anything. For example: http://www.google.com becomes XxX But what I'm after is not to replace the link with something but to remove everything else and just leave the link. I want a... (5 Replies)
Discussion started by: muxman
5 Replies

2. Shell Programming and Scripting

negate search help

Hi, I've tried a lot of negate codes in this forum, but they do not perform what I intended. Please help. inputfile: Paragraph1 contents: die1, die2, die3, pr_name1, pr_name2 pr_name3, pr_name4 Paragraph2 more contents: die1, die2, die3, pr_name1, pr_name2 pr_name3, pr_name4 ... (5 Replies)
Discussion started by: shamushamu
5 Replies

3. HP-UX

HPUX monitoring and alerting script per CPU

Hi Guys, Hopefully someone would be able to help me out. Basically I have an HPUX 11.11i system which is backed up by Data Protector 4.5. Every so often the vdba process hangs and chews up 100% of one of the systems CPU resources. As our monitoring tool can only monitor on a per system basis... (3 Replies)
Discussion started by: fulhamfcboy
3 Replies

4. Shell Programming and Scripting

Grep Alerting - command or script assistance

Hello! I need some help with grep from various logs we use for monitoring transactions. The logs contain the following information (which is consistent in all of the files): 12:28:33.157 EWY D 1 (tcpip.c:282): tcpip.c: Unable to connect to x.x.x.x on port xxxx. (79) Connection refused ... (1 Reply)
Discussion started by: sbchecko
1 Replies

5. UNIX for Dummies Questions & Answers

Code for alerting admin regarding process

Hello everyone. I want code for 1.reporting an alert to admin if a particular user tries to initiate more than 5 processes in the interval of 5 mins. 2. Reporting an alert if a user runs one particular process for more than 5 minutes. Both should be reported in a log file with machine... (1 Reply)
Discussion started by: safijunaid
1 Replies

6. Shell Programming and Scripting

How to negate pattern within sed?

Example: I have data like, H|1|2|#||4|4|5|6 D|f|g|h|j|j|k|k| D|f|g|h|j|j|k|k| D|f|g|h|j|j|k|k| D|f|g|h|j|j|k|k| D|f|g|h|j|j|k|k| T|g|g|G|G|g|g| T|g|g|G|G|g|g| I have to write command, it should delete all the lines except line starting with "D". I have tried sed '/^\(D\)|/!d'... (2 Replies)
Discussion started by: duplicate
2 Replies

7. Shell Programming and Scripting

How to get the negate of decimal to binary?

Hi All, New to this forum (and yes , a newbie in programming..:p) I have a decimal to binary converter script done this way : i=$1 bit0=$(( (i & 0x01) > 0 )) bit1=$(( (i & 0x02) > 0 )) bit2=$(( (i & 0x04) > 0 )) bit3=$(( (i & 0x08) > 0 )) bit4=$((... (6 Replies)
Discussion started by: digiteltlc
6 Replies

8. AIX

Rlogin alerting

// AIX 6.1 lsuser root returns the attributes. # lsuser root root id=0 pgrp=system groups=system,bin,sys,security,cron,audit,lp,dba,mqm,patrol home=/ shell=/usr/bin/ksh auditclasses=general log in=true su=true rlogin=false daemon=true admin=true sugroups=ALL... (2 Replies)
Discussion started by: Daniel Gate
2 Replies
metareplace(1M) 					  System Administration Commands					   metareplace(1M)

NAME
metareplace - enable or replace components of submirrors or RAID5 metadevices SYNOPSIS
/usr/sbin/metareplace -h /usr/sbin/metareplace [-s setname] -e mirror component /usr/sbin/metareplace [-s setname] mirror component-old component-new /usr/sbin/metareplace [-s setname] -e RAID component /usr/sbin/metareplace [-s setname] [-f] RAID component-old component-new DESCRIPTION
The metareplace command is used to enable or replace components (slices) within a submirror or a RAID5 metadevice. When you replace a component, the metareplace command automatically starts resyncing the new component with the rest of the metadevice. When the resync completes, the replaced component becomes readable and writable. If the failed component has been hot spare replaced, the hot spare is placed in the available state and made available for other hot spare replacements. Note that the new component must be large enough to replace the old component. A component may be in one of several states. The Last Erred and the Maintenance states require action. Always replace components in the Maintenance state first, followed by a resync and validation of data. After components requiring maintenance are fixed, validated, and resynced, components in the Last Erred state should be replaced. To avoid data loss, it is always best to back up all data before replacing Last Erred devices. OPTIONS
Root privileges are required for all of the following options except -h. -e Transitions the state of component to the available state and resyncs the failed component. If the failed component has been hot spare replaced, the hot spare is placed in the available state and made available for other hot spare replace- ments. This command is useful when a component fails due to human error (for example, accidentally turning off a disk), or because the component was physically replaced. In this case, the replacement component must be partitioned to match the disk being replaced before running the metareplace command. -f Forces the replacement of an errored component of a metadevice in which multiple components are in error. The component determined by the metastat display to be in the ``Maintenance'' state must be replaced first. This option may cause data to be fabricated since multiple components are in error. -h Display help message. -s setname Specifies the name of the diskset on which metareplace will work. Using the -s option will cause the command to perform its administrative function within the specified diskset. Without this option, the command will perform its function on local metadevices. mirror The metadevice name of the mirror. component The logical name for the physical slice (partition) on a disk drive, such as /dev/dsk/c0t0d0s2. component-old The physical slice that is being replaced. component-new The physical slice that is replacing component-old. RAID The metadevice name of the RAID5 device. EXAMPLES
Example 1: Recovering from Error Condition in RAID5 Metadevice This example shows how to recover when a single component in a RAID5 metadevice is errored. # metareplace d10 c3t0d0s2 c5t0d0s2 In this example, a RAID5 metadevice d10 has an errored component, c3t0d0s2, replaced by a new component, c5t0d0s2. Example 2: Use of -e After Physical Disk Replacement This example shows the use of the -e option after a physical disk in a submirror (a submirror of mirror d11, in this case) has been replaced. # metareplace -e d11 c1t4d0s2 Note: The replacement disk must be partitioned to match the disk it is replacing before running the metareplace command. EXIT STATUS
The following exit values are returned: 0 Successful completion. >0 An error occurred. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWmdu | +-----------------------------+-----------------------------+ SEE ALSO
mdmonitord(1M), metaclear(1M), metadb(1M), metadetach(1M), metahs(1M), metainit(1M), metaoffline(1M), metaonline(1M), metaparam(1M), metarecover(1M), metarename(1M), metaroot(1M), metaset(1M), metassist(1M), metastat(1M), metasync(1M), metattach(1M), md.tab(4), md.cf(4), mddb.cf(4), md.tab(4), attributes(5), md(7D) Solaris Volume Manager Administration Guide SunOS 5.10 8 Aug 2003 metareplace(1M)