07-27-2009
LUN Reservation and Clearence
Hello Everyone,
I wud like to knw what we mean by LUN reservation and how to clear the LUN reservation in AIX.
Regards,
nivas
8 More Discussions You Might Find Interesting
1. Solaris
I have a list of LUN ID, my task is to find if disk has been added or not. How do I do that? I have been searching the forum and not able to find answer.
thanks (4 Replies)
Discussion started by: uuontario
4 Replies
2. AIX
Hello all,
I have the following env:
* DS4300 storage SAN
* AIX 5.3 Lpar (storage through vio server)
* AIX 5.3 Server
Some FS are too small do I'm setting up a process to increase the size of the FS.
To expand the size of the FS I plan to do the following for the physical AIX server,... (1 Reply)
Discussion started by: petervg
1 Replies
3. Red Hat
Hi,
Is there command to detect the newly added LUN is linux box. I tried with below commands, but that doesn't work out.
fdisk -l,
fdisk -l | grep Disk
pvscan (5 Replies)
Discussion started by: gsiva
5 Replies
4. AIX
Hi,
I am not getiting lun id information on VIO Server. I have used the command fget_config command.
just showing # prompt.
I would like know wheather any other command is there equiv of fget_config
which will display lun id? (4 Replies)
Discussion started by: manoj.solaris
4 Replies
5. Solaris
Dear all,
i want to get the LUN ID for some disks in solaris 10
what commands options for the MPXIO and inq i want these utilities only
because i don't have solution enabler or powerpath
BR, (1 Reply)
Discussion started by: maxim42
1 Replies
6. Solaris
Hi All,
I am a RH Linux admin that recently started working at a company with a number of SUN Servers so it's been an interesting transition.
Considering the last person left with very little documentation left behind so I have been picking up most issues half complete, or troubleshot.
... (7 Replies)
Discussion started by: MobileGSP
7 Replies
7. HP-UX
Hi guys,
I need some help to better understand how to determine if a disk have persistent SCSI reservation. I know that we should use the "Persisten Reservation Utility" but we are not allowed to run that tool. Since we have the output from some grab utility and specifically we have the... (0 Replies)
Discussion started by: cecco16
0 Replies
8. Solaris
Hi
I am having two node cluster. I was trying to change the to use scsi3 reservation for all disks having two paths. Please let me know where I went wrong or there any issue to implement the same.
On node1
bash-3.2# cldev status
=== Cluster DID Devices ===
Device Instance ... (8 Replies)
Discussion started by: sb200
8 Replies
SG_RDAC(8) SG3_UTILS SG_RDAC(8)
NAME
sg_rdac - Display or Modify RDAC Redundant Controller Page
SYNOPSIS
sg_rdac [-a] [-f=LUN] [-v] [-V] DEVICE
DESCRIPTION
sg_rdac displays or modifies the RDAC controller settings via the Redundant Controller Page (0x2C). When modifying the settings it allows
to transfer the ownership of individual drives to the controller the command was received on.
OPTIONS
-a Transfer all (visible) devices
-f=LUN Transfer the device identified by LUN. This command will only work if the controller supports 'Dual Active Mode' (aka active/active
mode).
-v be verbose
-V print version string then exit
EXIT STATUS
The exit status of sg_rdac is 0 when it is successful. Otherwise see the sg3_utils(8) man page.
AUTHOR
Written by Hannes Reinecke <hare at suse dot com>, based on sg_emc_trespass.
REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>.
COPYRIGHT
Copyright (C) 2006-2007 Hannes Reinecke, Douglas Gilbert.
This software is distributed under the GPL version 2. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR-
POSE.
sg3_utils-1.23 January 2007 SG_RDAC(8)