Sponsored Content
Full Discussion: T2000 RAID Question
Operating Systems Solaris T2000 RAID Question Post 302334344 by achenle on Wednesday 15th of July 2009 09:53:38 AM
Old 07-15-2009
I'm pretty sure the RAID chip on the T2000 is an LSI 1064-based SAS controller.

Go to LSI's web site and find the "lsiutil" utility for Solaris SPARC. You should be able to use that to set up a RAID-1 mirror without having to do a reinstall or lose any data.

But I'd have everything backed up anyway.
 

10 More Discussions You Might Find Interesting

1. AIX

RS6000 SSA Raid question

Hi Can I add disks on the fly to extend the capacity of an existing RAID 5 volume? It's created on a 4P Advanced SSA Raid Adapter. I need to extend a volume group, so I figured it would be easiest to extend the "physical disk" which is a RAID5 volume. Thanks. (1 Reply)
Discussion started by: osee
1 Replies

2. Solaris

X4100 Bios RAID question

Hi there the Sunfire X4100 has a great tool that you can get to from BIOS called the configuration utility which allows you to set up Disk mirroring (RAID 1) before the OS sees it, which is great and it works a treat, however, we have a large datacentre across multiuple sites and I need to find... (1 Reply)
Discussion started by: hcclnoodles
1 Replies

3. Solaris

How to setup hardware RAID on a T2000

Hello all We've just bought a T2000. It has two disks and I'm trying to figure out how to create a mirror of the boot disk. I understand that I have to boot into single user mode from DVD and then use the raidctl command to set up the mirror and label the volume afterwards. Format returns... (4 Replies)
Discussion started by: soliberus
4 Replies

4. Solaris

T2000 Hardware RAID

Hi, I have a root with hardware RAID on c0t0d0 and c0t2d0. I would like to set the boot device sequence in OBP for both hdds. I have checked in ls -l /dev/rdsk/ for the path of c0t2d0 but it does not exist. Can anyone shed some lights on this? AVAILABLE DISK SELECTIONS: 0.... (12 Replies)
Discussion started by: honmin
12 Replies

5. SuSE

openSuse 11.1 RAID 0 Question

Hello, I have a file server running openSuse 11.1, that has two HDDs running in RAID 0 (mirroring) using the md software RAID linux driver. I was considering removing this RAID, using one of the drives as the OS and the other as a data drive. Is there any way to stop using this as a RAID set to do... (4 Replies)
Discussion started by: vwgtiturbo
4 Replies

6. Solaris

Raid problem on T2000

Hi all, First post so be gentile :) It's my first time installing Solaris on T2000 server. I have 2 72GB HD's on it. After configuring HW raid and running raidctl command I get this output: bash-3.00# raidctl -l c0t0d0 Volume Size Stripe Status Cache RAID ... (2 Replies)
Discussion started by: Obi-Wan
2 Replies

7. Solaris

Sun T2000 question

This may be a stupid question, but I don't want to take any chances. I have a Sun T2000 in production. I want to run the "resetsc" command on the ALOM controller to active an IP address change. Will resetting ALOM affect the running OS? Thanks (2 Replies)
Discussion started by: soliberus
2 Replies

8. Hardware

Hardware RAID on Sun T2000 Server

Hi All I have a Sun T2000 server. Couple of years ago I had configured and mirrored the boot drive with an other drive using hardware RAID 1 using raidctl command. Following is the hardware RAID output. root@oracledatabaseserver / $ raidctl RAID Volume RAID RAID Disk... (0 Replies)
Discussion started by: Tirmazi
0 Replies

9. UNIX for Dummies Questions & Answers

RAID on Solaris Question

Hello folks; I'm trying to install Solaris 10 x86 on SUN X4150 box with 6 disks in it, the question is how can i create a Virtual disk like RAID 0 before i install Solaris. When i boot up i don't see any option to go and create my raid before the installation begin. Thanks in advance for any... (2 Replies)
Discussion started by: Katkota
2 Replies

10. Solaris

Sun V240 Raid Question

Hi All, I'm new to this site. I have a few question since I'm in the process how to to repair my raid on Sun V240 Server. 1. How can we create RAID in Sun Sparc v240? 2. What utility can help people create RAID in Sun Sparc v240? 3. Do we need any special software to create the... (12 Replies)
Discussion started by: angkor
12 Replies
MPS(4)							   BSD Kernel Interfaces Manual 						    MPS(4)

NAME
mps -- LSI Fusion-MPT 2 Serial Attached SCSI driver SYNOPSIS
To compile this driver into your kernel, place the following lines in your kernel configuration file: device scbus device mps Or, to load the driver as a module at boot, place the following line in loader.conf(5): mps_load="YES" DESCRIPTION
The mps driver provides support for LSI Logic Fusion-MPT 2 SAS controllers and WarpDrive solid state storage cards. HARDWARE
The mps driver supports the following hardware: o LSI Logic SAS2004 (4 Port SAS) o LSI Logic SAS2008 (8 Port SAS) o LSI Logic SAS2108 (8 Port SAS) o LSI Logic SAS2116 (16 Port SAS) o LSI Logic SAS2208 (8 Port SAS) o LSI Logic SAS2308 (8 Port SAS) o LSI Logic SSS6200 Solid State Storage o Intel Integrated RAID Module RMS25JB040 o Intel Integrated RAID Module RMS25JB080 o Intel Integrated RAID Module RMS25KB040 o Intel Integrated RAID Module RMS25KB080 CONFIGURATION
To disable MSI interrupts for all mps driver instances, set the following tunable value in loader.conf(5): hw.mps.disable_msi=1 To disable MSI interrupts for a specific mps driver instance, set the following tunable value in loader.conf(5): dev.mps.X.disable_msi=1 where X is the adapter number. To disable MSI-X interrupts for all mps driver instances, set the following tunable value in loader.conf(5): hw.mps.disable_msix=1 To disable MSI-X interrupts for a specific mps driver instance, set the following tunable value in loader.conf(5): dev.mps.X.disable_msix=1 To set the maximum number of DMA chains allocated for all adapters, set the following variable in loader.conf(5): hw.mps.max_chains=NNNN To set the maximum number of DMA chains allocated for a specific adapter, set the following variable in loader.conf(5): dev.mps.X.max_chains=NNNN This variable may also be viewed via sysctl(8) to see the maximum set for a given adapter. The current number of free chain frames may be seen via the dev.mps.X.chain_free sysctl(8) variable. The lowest number of free chain frames may be seen via the dev.mps.X.chain_free_lowwater sysctl(8) variable. The current number of active I/O commands is shown in the dev.mps.X.io_cmds_active sysctl(8) variable. The maximum number of active I/O command seen since boot is shown in the dev.mps.X.io_cmds_highwater sysctl(8) variable. DEBUGGING
To enable debugging prints from the mps driver, set the hw.mps.X.debug_level variable, where X is the adapter number, either in loader.conf(5) or via sysctl(8). The following bits have the described effects: 0x01 Enable informational prints. 0x02 Enable tracing prints. 0x04 Enable prints for driver faults. 0x08 Enable prints for controller events. SEE ALSO
cd(4), ch(4), da(4), mpt(4), pci(4), sa(4), scsi(4), targ(4), loader.conf(5), sysctl(8) HISTORY
The mps driver first appeared in FreeBSD 9.0. AUTHORS
The mps driver was originally written by Scott Long <scottl@FreeBSD.org>. It has been improved and tested by LSI Logic Corporation. This man page was written by Ken Merry <ken@FreeBSD.org>. BUGS
This driver has a couple of known shortcomings: o No userland utility available (e.g. mptutil(8)). o The driver probes devices sequentially. If your system has a large number of devices, the probe will take a while. BSD
January 3, 2013 BSD
All times are GMT -4. The time now is 05:59 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy