06-29-2009
change SP value in powerpath
How to change the following values in power path from SP B to SP A ?
Owner: default=SP B, current=SP B
this is excerpt from powermt display dev=all
10 More Discussions You Might Find Interesting
1. Filesystems, Disks and Memory
We currently have a Solaris box connected to a Clariion storage system that is utilising DMP for path failover. I would prefer to use EMC's Powerpath and was wondering if the two can coexist?
Basically, I am struggling to find any documentation on the subject and was wonder if anyone can give me... (2 Replies)
Discussion started by: aaron2k
2 Replies
2. AIX
Hi Guys,
I have a problem while trying to upgrade to more current EMC powerpath software on AIX 5.3 - respectively uninstalling the existing one.
I tried to deinstall the powerpath software with removed disks - was working perfectly fine on 12 servers - but number 13 is failing with errors:
... (4 Replies)
Discussion started by: zxmaus
4 Replies
3. Red Hat
Hi ,
I have a redhat 5.3 server which has 2 vg.. one is rootvg in local harddisk and another one is applicationvg in SAN.. When I reboot the server , EMC powerpath driver is not starting up automatically. Hence applicationvg is not mounting properly. Therefore I need to unmount it manually and... (4 Replies)
Discussion started by: Makri
4 Replies
4. Solaris
Hello,
I have an issue with veritas volume manager version 5.0 in combination with EMC powerpath version 5.2.0 running on Solaris10(Sparc). This server is fiber connected to a EMC Clariion CX3-40 SAN.
This is the situation :
Server is a SUN Enterprise M5000
OS = Solaris10 Sparc
Veritas... (1 Reply)
Discussion started by: chipke2005
1 Replies
5. Solaris
Here is the issue:
I am building a database server using Solaris 10x86 U8.
The system is jumpstarted with mpxio enabled and booting from the san.
We need to have powerpath 5.3 installed and would like to have powerpath take control of the the boot san as well or have mpxio control the san... (2 Replies)
Discussion started by: nabru72
2 Replies
6. AIX
Hi All,
I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV.
My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies
7. Linux
Hello guys, I'm going crazy over here with a problem with a LUN created on a EMC CX3.
I did sucessfully managed to create the LUN on the Storage (the LUN is named DBLNX25EC_TST), after doing the following process:
echo "1" > /sys/class/fc_host/host<n>/issue_lip
and
echo "- - -" >... (10 Replies)
Discussion started by: Zarnick
10 Replies
8. Solaris
Hi all
I am running the following hardware:
2 SUN Solaris 10 machines
They are connected to EMC clarion LUNs
We are running a Sun Cluster 3.2 managing both nodes
We are using Solaris Volume Manager to handle the shared storage for the cluster. It is using a number of named disk sets that is... (0 Replies)
Discussion started by: abohmeed
0 Replies
9. Solaris
It seems like I lost one path on my Solaris-11 box. But I want to make sure before going to Storage team, if issue is from OS side or Storage side. Storage team is able to see that only one wwwn is looged in their switch. I am not at server's physical location. What does below output says ? I... (0 Replies)
Discussion started by: solaris_1977
0 Replies
10. Solaris
Hi,
We're trying out a SAN migration from HP EVA to EMC VMAX, and run into a bit of an issue with powerpath and zfs.
The method we're currently using to migrate is to export the HP EVA luns from our sun server, replicate using SAN based method, and then present the new luns to our Sun server... (7 Replies)
Discussion started by: badoshi
7 Replies
LEARN ABOUT DEBIAN
acpi_sony
ACPI_SONY(4) BSD/i386 Kernel Interfaces Manual ACPI_SONY(4)
NAME
acpi_sony -- ACPI notebook controller driver for Sony laptops
SYNOPSIS
To compile this driver into the kernel, place the following line in your kernel configuration file:
device acpi_sony
Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5):
acpi_sony_load="YES"
DESCRIPTION
The acpi_sony driver provides support for the notebook controller in Sony laptops. Note that not all features will work on all laptop mod-
els.
SYSCTLS
The following sysctl nodes are currently implemented:
dev.acpi_sony.0.brightness
Current brightness level of the display.
dev.acpi_sony.0.brightness_default
Default brightness level of the display (survives reboot).
dev.acpi_sony.0.contrast
Current contrast level of the display.
dev.acpi_sony.0.bass_gain
Enable or disable the Bass Gain feature.
dev.acpi_sony.0.cdp
Turns the CD power on or off.
dev.acpi_sony.0.azp
Turns the audio power on or off.
dev.acpi_sony.0.lnp
Turns the wired network interface power on or off.
SEE ALSO
acpi(4), sysctl(8)
HISTORY
The acpi_sony driver first appeared in FreeBSD 6.0.
AUTHORS
The acpi_sony driver was written by Takanori Watanabe <takawata@FreeBSD.org>.
BSD
February 7, 2010 BSD