06-22-2009
Hi All i usually using
#reboot for rebooy system
and
#poweroff to shutdown
what that i do is right or not make server problem?
Thanks
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
I've never been on a Unix machine so please be easy on me!!!
I need to create a step by step process for the Unix start up and shut down process.
Thanks for any help in advance. (3 Replies)
Discussion started by: chaughney
3 Replies
2. UNIX for Dummies Questions & Answers
ok i am pretty new i am thinking this maybe a dns situatioan i dunno....
i am trying to start nfs server i get the followin error:
mountd svc_tli create could not bind to requested address: address mismatch
svc_create: svc_tli_create failed
/usr/lib/nfs/nfsd : tli_bind to wrong address... (14 Replies)
Discussion started by: rmuhammad
14 Replies
3. Shell Programming and Scripting
Hi ,
Good day people. I want to know if i can shut down a particular service that runs in windows from solaris through a script .
Scenario : we have a distributed environment where we want to shut down a service that runs under windows through a shell script in solaris , is this kinda action... (3 Replies)
Discussion started by: vivsiv
3 Replies
4. UNIX for Advanced & Expert Users
Hi,
I have created a user to shutdown the server using RBAC.
Here are my steps:
1. roleadd -u 1000 -g 10 -d /home/stopsys -m stopsys
2. passwd stopsys
3. edit /etc/security/prof_attr to include:
Shut:::able to shut the server:
4. modrole -P Shut stopsys
5. useradd -u 1001 -g 10 -d... (2 Replies)
Discussion started by: chaandana
2 Replies
5. Shell Programming and Scripting
Hi,
I want to automate process of making server up and down.
For us making server up and down is just to go to particular directory in user directories (in Unix box) and running start and stop shell script .
We have to run the same things on 5 users on same server .
Can anybody suggest... (1 Reply)
Discussion started by: shekhar_ssm
1 Replies
6. UNIX for Dummies Questions & Answers
I have a problem with my unix server. Can anyone please teach me how to start the mailx running... . (16 Replies)
Discussion started by: filthymonk
16 Replies
7. UNIX for Advanced & Expert Users
Hi to all,
i cant start my x server.
I use putty and xming.
When i type xclock i get no promt back and i must type ctrl+c to get promt again.
start x is giving me:
$ startx
Fatal server error:
PAM authentication failed, cannot start X server.
Perhaps you do not have console... (3 Replies)
Discussion started by: ttoni
3 Replies
8. Linux
Hi,
I have installed mysql in linux box as mysql-5.0.77-4.el5_6.6..
I would like to start the server. But there is no mysql file in this location /etc/init.d/
Please advice how to start the server now !!
Thnaks,
Mani (5 Replies)
Discussion started by: Mani_apr08
5 Replies
9. Red Hat
I had a query that should the RHEL servers in production environment be re-started say every 2-3 months so that the cache is cleared?
I hope, my question is clear that should the Red Hat Linux servers be restarted periodically.
Please revert with the reply to my query.
Regards (17 Replies)
Discussion started by: RHCE
17 Replies
10. UNIX and Linux Applications
Good afternoon
I need your help please.
There is a Mantenance Windos which needs to Restart de Database Server 192.x.x.97 to set up some configuration
Is it mandatory or not to stop/start Applcation server that runs in 192.x.x.95 ?
Is it mandatory or not to stop/start apache and Tomcat?... (3 Replies)
Discussion started by: alexcol
3 Replies
UPSCODE2(8) NUT Manual UPSCODE2(8)
NAME
upscode2 - Driver for UPScode II compatible UPS equipment
NOTE
This man page only documents the hardware-specific features of the upscode2 driver. For information about the core driver, see
nutupsdrv(8).
SUPPORTED HARDWARE
This driver supports UPS equipment which can be controlled via the UPScode II protocol. This is mainly Fiskars, Powerware equipment, but
also some (probably OEM'ed) products from Compaq.
EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5):
manufacturer=value
Autodetection of this parameter is not possible yet (and it probably never will be). Therefore, this user-defined string accepts any
name. The default is unknown.
input_timeout=value
The timeout waiting for a response from the UPS. Some UPS models have shown to be rather slow, resulting in frequent messages about
empty responses from the UPS. If you see this, try increasing this value.
output_pace=value
Delay between characters sent to the UPS. This was added for completeness with the above parameter. It has not shown to be needed yet.
baudrate=value
The default baudrate is 1200, which is the standard for the UPScode II protocol.
full_update_timer=value
Number of seconds between collection of normative values.
use_crlf
Flag to set if commands towards to UPS need to be terminated with CR-LF, and not just CR.
use_pre_lf
Flag to set if commands towards to UPS need to be introduced with an LF. A Compaq T1500h is known to need this.
COMMANDS
The driver supports the following commands for those UPSen that support them. The available commands are autodetected during
initialization, so you should check availability with upscmd -l.
o test.panel.start - Start UPS self test
o test.battery.start - Start battery self test
o beeper.enable - Enable UPS beeper
o beeper.disable - Disable UPS beeper
o shutdown.return - Shut down in 1 second and wait for power to return
o shutdown.stayoff - Shut down in 1 seconds
o shutdown.reboot - Shut down in 1 seconds and reboot after 1 minute
o shutdown.reboot.graceful - Shut down in 20 seconds and reboot after 1 minute
NOTES
The Powerware UPS models that this driver has been tested against until now have not returned a value for battery.charge. Therefore, the
driver will guestimate a value based on the nominal battery min/max and the current battery voltage.
AUTHOR
Havard Lygre <hklygre@online.no>, Niels Baggesen <niels@baggesen.net>
SEE ALSO
The core driver:
nutupsdrv(8)
Internet resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
Network UPS Tools 05/21/2012 UPSCODE2(8)