Sponsored Content
Operating Systems AIX Virtual Ethernet VIO HMC LPARs Post 302325563 by Padow on Monday 15th of June 2009 01:39:07 PM
Old 06-15-2009
  1. I tend not to give IP's to the adapters I create for sea on the vio servers.
  2. Yes, you should use a different VLAN ID for each subnet you create virtual adapters for.
  3. The etherchannel setup is a good idea for failover between the two vio servers, but I would only use the backup adapter feature rather than combining the two adapters.
Padow
 

9 More Discussions You Might Find Interesting

1. AIX

Help urgent : vio server - add extral disk on virtual lpar

Hi, I define 2 new LV on the vio server and run a cfgmgr on the partition and see my 2 new hdisk (hdisk6 and hdisk7). I extend my vg vg000 (on the partition) and add the 2 hdisks. I had a filesystem on the vg000 and when I added the disk I would like to increase the filesystem. But I cannot do a... (0 Replies)
Discussion started by: touny
0 Replies

2. UNIX for Advanced & Expert Users

Virtual Ethernet

I understand that one should setup virtual ethernet adapters in the lpars which is the best way for various lpars to communicate with each other - Does anyone have info on this or can point me to a doc that explains how to set this up? (1 Reply)
Discussion started by: capeme
1 Replies

3. AIX

Virtual Ethernet with VIO

We're using VIO (not an HMC) to manage our LPAR's We have 3 physical adapters and 4 LPARs. Through the VIO interface we assigned 2 virtual interfaces but require a 3rd interface assigned to these LPARs. I am experiencing issues understanding exactly how to create another virtual adapter, either... (1 Reply)
Discussion started by: scottsl
1 Replies

4. AIX

CDROM Issue on LPAR HMC VIO

Whenever I assign/unassign a CDROM ( RAID CTRL ) to Active LPAR from HMC, I have to reboot the LPAR. How can I do it without rebooting the LPARS. POWER6 with HMC LPARS = AIX 6.1 Any info developerWorks : AIX and UNIX : PowerVM Forum : Moving CD-ROM/DVD-ROM dynamically ... But... (5 Replies)
Discussion started by: filosophizer
5 Replies

5. AIX

Inherited VIO server an LPARs

Lucky me, someone has installed a server and got it running with the best intentions, but leaving me a headache. :wall: We have a simple p520 with 4 disks. 2x145Gb & 2x300Gb. The smaller disk pair have been built into a VIO mirrored rootvg, and quite right too. The other two disks form a... (3 Replies)
Discussion started by: rbatte1
3 Replies

6. AIX

Setting up an Integrated Virtual Ethernet adapter

All I am trying allocate an IVE to an LPAR (not a VIO) running AIX 7.1. I am getting the error: HSCL068A Explanation Logical port can not be assigned to Logical Partition because this Logical Partition is not the promiscuous LPAR for the physical port. Has anyone encountered this... (1 Reply)
Discussion started by: johnf
1 Replies

7. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

8. AIX

Connecting system to Virtual HMC

Hi, I just successfully build a Virtual Machine in virtual box with Perfectly running HMC v7. I have a IBM eServer pSeries Model 630 Model 6C4 (Power 4) i.e. 7024-6C4. I am not able to have it connect to the HMC console on the Virtual Box. Can anyone help me on how to connect it to the... (8 Replies)
Discussion started by: uzair_rock
8 Replies

9. AIX

Need to replace a broken PV in a VIO VG used for client LPARs (and it won't release the old one)

I have a broken PV in a VIO VG that's used to support client LPARs using LVs. On the client LPAR, I reduced all PVs from the relevant client VG and thus deleted it. I.e. there is no client LPAR using the VIO VG. Yet when I try to reducevg the VIO VG, it complains that the LV hosted on the PV is... (2 Replies)
Discussion started by: maraixadm
2 Replies
scconf_transp_adap_sci(1M)				  System Administration Commands				scconf_transp_adap_sci(1M)

NAME
scconf_transp_adap_sci - configure the sci cluster transport adapter DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. You can configure sci SCI-PCI adapters as cluster transport adapters. These adapters can be used with the dlpi transport type. The adapter name is sciN, for example, sci0. Do not use scidN as the adapter name. An sci adapter can only be connected to another sci adapter or to an SCI switch. When an sci adapter is connected to an SCI switch, it is important that you specify the correct port name when referring to a port on the switch as an endpoint argument to the scconf or scinstall utility. The port name must match the port number on the SCI switch (the number that is printed on the switch itself). Failure to give the correct port name could result in the operation failing. The result of providing an incorrect port name will be the same as you would see if the cable between the adapter and the switch were removed. There are no user-configurable properties for cluster transport adapters of this type. SEE ALSO
Intro(1CL), clinterconnect(1CL), clnode(1CL), scconf(1M), scconf_transp_jct_dolphinswitch(1M), scinstall(1M) Sun Cluster 3.2 4 May 2006 scconf_transp_adap_sci(1M)