04-18-2009
plug in the new disk.
devfsadm -C
make sure format can see the added disk
vxdctl enable
use vxdiskadm ---> option 4 to confirm that the disk was removed.
----option 5, to attach the new disk to the disk group
10 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
hi,
i have a volume on a LUN of an EMC-storage and i need to increase the
size.
i could increase the size of the LUN on the EMC, i could increase the
size of the disk for solaris, but how can i tell the veritas volume
manager that the disk is larger now?
what i've done:
1. LUN on EMC
2.... (3 Replies)
Discussion started by: pressy
3 Replies
2. Solaris
VxVM:
How to add one more disk into v08 the stripe should change from 7/128 to 8/128
v v08 - ENABLED ACTIVE 8954292224 SELECT v08-01 fsgen
pl v08-01 v08 ENABLED ACTIVE 8954292480 STRIPE 7/128 RW
sd bkpdg35-01 v08-01 bkpdg35 17216 ... (0 Replies)
Discussion started by: geoffry
0 Replies
3. Solaris
Hi, Im getting a downtime of 4 hrs to do porting of bootdisks.
Currently, the system is running on Sf4800. 2 internal disk 36G connected to a SE3510 storage.
We're getting 72G disks and we want to restore the OS from the current 36G to the 72G disk. System is under veritas volume manager ctrl.... (4 Replies)
Discussion started by: incredible
4 Replies
4. Solaris
Hi All,
We had a Sun Netra T1 go down the other day, the root disk was mirrored using vxvm. Upon boot from either disk, we had the following error appear:
WARNING: Error writing ufs log state
WARNING: ufs log for / changed state to Error
WARNING: Please umount(1M) / and run... (4 Replies)
Discussion started by: badoshi
4 Replies
5. Solaris
Hi,
Anyone can help me, just want to confirm, if possible adding a disk storage that we have a RAWDATA with +ASM in our database. If possible, what would you recommend "workaround used" from us to do and the preparation. And also how long the downtime will take.
Our disk continuous to grow,... (0 Replies)
Discussion started by: fpalero
0 Replies
6. Solaris
Hi,
I am new to solaris administration. I have scan the new EMC SAN disk. I am able to see the disk when i run the powermt display dev=all command o/p. I want to format the disk and add file system to that disk.
Can have formated the disk. and this the o/p of my format
bash-3.00# prtvtoc... (3 Replies)
Discussion started by: jpkumar10
3 Replies
7. Solaris
Hi,
Can you help me on booting x86 server configured under VxVM. Server boots fine normally from both the disks but if I try to boot server from mirror disk without starting veritas, then it does not boot.
vxplex -g rootdg dis var-02
vxplex -g rootdg dis swapvol-02
vxplex -g rootdg dis... (2 Replies)
Discussion started by: milindphanse604
2 Replies
8. Emergency UNIX and Linux Support
I have VxVM 5.1 running on Solaris-10. I have to increase a application file-system and storage team gave me a lun. After scanning scsi port by cfgadm, I can see them in format output. I labelled it, but I am not able to see them in "vxdisk list".
I already tried commands -->
vxdctl enable... (4 Replies)
Discussion started by: solaris_1977
4 Replies
9. HP-UX
Hello all,
So I made a rookie mistake today. I forgot to remove my disk from my disk group, before running the following command:for i in `ioscan -fnN | awk /NO/'{print $3}'`
do
rmsf -H $i
done
I am trying to run the following command, but not having any luck obviously:vxdg -g dgvol1 rmdisk... (0 Replies)
Discussion started by: mrkejames2
0 Replies
10. Solaris
On an OmniOS server, I removed a single-disk pool I was using for testing.
Now, when I run zpool import it will show it as FAULTED, since that single disk not available anymore.
# zpool import
pool: fido
id: 7452075738474086658
state: FAULTED
status: The pool was last... (11 Replies)
Discussion started by: priyadarshan
11 Replies
pfto(7) Miscellaneous Information Manual pfto(7)
NAME
pfto - Powerfail Timeout
DESCRIPTION
HP-UX SCSI disk device drivers have a timeout facility that detects non-responding disks. VxVM uses this mechanism in its Powerfail Time-
out (pfto) feature. You can specify a timeout value for individual VxVM disks using the vxdisk command (see the EXAMPLES section below).
If a disk fails to respond in the specified timeout period, the driver receives a timer interrupt.
pfto values are persistent across reboots, that is, after the pfto value is set, it remains in effect until you explicitly change it. If
dynamic multipathing is enabled, the pfto value set on a disk applies to each path of a multipath disk device.
The pfto value is in seconds. If pfto is not specified, or is zero, the timeout period is 30 seconds. Both the vxdisk and vxprint commands
display the current pfto value for a disk.
EXAMPLES
Use the following command to set the value of pfto to 30 seconds on disk01:
vxdisk -g rootdg set disk01 pfto=30
Use either of the following commands to display the pfto value on the VxVM disk disk01:
vxdisk list disk01
vxprint -l disk01
EXIT CODES
Setting the pfto value on a non-VxVM disk returns an error.
SEE ALSO
vxdisk(1M), vxprint(1M)