04-18-2009
( VxVM ) How to add the removed disk back to previous disk group
Previously , i remove the disk by
#vxdg -g testdg -k rmdisk testdg02
But i got error when i -k adddisk
bash-2.03# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 auto:none - - online invalid
c0t1d0s2 auto:none - - online invalid
c4t129d0s2 auto:cdsdisk - - online
c4t129d1s2 auto:cdsdisk testdg01 testdg online
- - testdg02 testdg removed was:c4t129d0s2
bash-2.03# vxdg -g testdg -k adddisk testdg02=c4t129d0
VxVM vxdg ERROR V-5-1-2349 Device c4t129d0s2 appears to be owned by disk group testdg.
10 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
hi,
i have a volume on a LUN of an EMC-storage and i need to increase the
size.
i could increase the size of the LUN on the EMC, i could increase the
size of the disk for solaris, but how can i tell the veritas volume
manager that the disk is larger now?
what i've done:
1. LUN on EMC
2.... (3 Replies)
Discussion started by: pressy
3 Replies
2. Solaris
VxVM:
How to add one more disk into v08 the stripe should change from 7/128 to 8/128
v v08 - ENABLED ACTIVE 8954292224 SELECT v08-01 fsgen
pl v08-01 v08 ENABLED ACTIVE 8954292480 STRIPE 7/128 RW
sd bkpdg35-01 v08-01 bkpdg35 17216 ... (0 Replies)
Discussion started by: geoffry
0 Replies
3. Solaris
Hi, Im getting a downtime of 4 hrs to do porting of bootdisks.
Currently, the system is running on Sf4800. 2 internal disk 36G connected to a SE3510 storage.
We're getting 72G disks and we want to restore the OS from the current 36G to the 72G disk. System is under veritas volume manager ctrl.... (4 Replies)
Discussion started by: incredible
4 Replies
4. Solaris
Hi All,
We had a Sun Netra T1 go down the other day, the root disk was mirrored using vxvm. Upon boot from either disk, we had the following error appear:
WARNING: Error writing ufs log state
WARNING: ufs log for / changed state to Error
WARNING: Please umount(1M) / and run... (4 Replies)
Discussion started by: badoshi
4 Replies
5. Solaris
Hi,
Anyone can help me, just want to confirm, if possible adding a disk storage that we have a RAWDATA with +ASM in our database. If possible, what would you recommend "workaround used" from us to do and the preparation. And also how long the downtime will take.
Our disk continuous to grow,... (0 Replies)
Discussion started by: fpalero
0 Replies
6. Solaris
Hi,
I am new to solaris administration. I have scan the new EMC SAN disk. I am able to see the disk when i run the powermt display dev=all command o/p. I want to format the disk and add file system to that disk.
Can have formated the disk. and this the o/p of my format
bash-3.00# prtvtoc... (3 Replies)
Discussion started by: jpkumar10
3 Replies
7. Solaris
Hi,
Can you help me on booting x86 server configured under VxVM. Server boots fine normally from both the disks but if I try to boot server from mirror disk without starting veritas, then it does not boot.
vxplex -g rootdg dis var-02
vxplex -g rootdg dis swapvol-02
vxplex -g rootdg dis... (2 Replies)
Discussion started by: milindphanse604
2 Replies
8. Emergency UNIX and Linux Support
I have VxVM 5.1 running on Solaris-10. I have to increase a application file-system and storage team gave me a lun. After scanning scsi port by cfgadm, I can see them in format output. I labelled it, but I am not able to see them in "vxdisk list".
I already tried commands -->
vxdctl enable... (4 Replies)
Discussion started by: solaris_1977
4 Replies
9. HP-UX
Hello all,
So I made a rookie mistake today. I forgot to remove my disk from my disk group, before running the following command:for i in `ioscan -fnN | awk /NO/'{print $3}'`
do
rmsf -H $i
done
I am trying to run the following command, but not having any luck obviously:vxdg -g dgvol1 rmdisk... (0 Replies)
Discussion started by: mrkejames2
0 Replies
10. Solaris
On an OmniOS server, I removed a single-disk pool I was using for testing.
Now, when I run zpool import it will show it as FAULTED, since that single disk not available anymore.
# zpool import
pool: fido
id: 7452075738474086658
state: FAULTED
status: The pool was last... (11 Replies)
Discussion started by: priyadarshan
11 Replies
vxpfto(1M) vxpfto(1M)
NAME
vxpfto - set Powerfail Timeout (pfto)
SYNOPSIS
vxpfto -g diskgroup -t timeout
vxpfto [-g diskgroup] -t timeout volume_list
vxpfto [-g diskgroup] -o pftostate={enabled|disabled}
vxpfto [-g diskgroup] -o pftostate={enabled|disabled} volume_list
DESCRIPTION
Powerfail Timeout is an attribute of a SCSI disk connected to an HP-UX host (see the pfto(7) man page). The vxpfto command sets the Power-
fail Timeout interval on a set of Volume Manager disks, either all disks in a disk group, or all disks underlying the volumes listed.
The first form of the command sets the same PFTO value for all the disks in the specified VxVM diskgroup.
In the second form, all disks underlying the given list of volumes are selected, optionally restricted by the disk group specified with the
-g option. If you specify a diskgroup, any volume in the list not belonging to the diskgroup is ignored.
Use the -o pftostate option to disable or enable PFTO. By default, PFTO is enabled. You can enable PFTO either on all disks in a disk
group, or on all disks underlying the volumes listed.
If you invoke vxpfto without arguments, it displays a usage message.
OPTIONS
-g diskgroup
Specifies the disk group for the operation, either by disk group ID or by disk group name.
-o pftostate={enabled|disabled}
Enables or disables the use of PFTO for IO.
-t timeout
Specifies the PFTO value in seconds. The value must be zero or a positive integer. Zero represents the system default PFTO
value. The default value depends on the disk driver controlling the disk device.
volume_list
A list of VxVM volume names. List items must be separated by white-space.
EXIT CODES
vxpfto returns a zero if successful. If it encounters an error, vxpfto exits and displays a message on standard error. Defined exit codes
are:
0 Success.
1 No PFTO value specified.
2 No diskgroup or volume list specified.
3 Illegal PFTO value specified.
EXAMPLES
Set the PFTO value on all disks in disk group testdg to 100 seconds:
vxpfto -t 100 -g testdg
Set the PFTO value to 50 seconds on all disks underlying volume01 and volume02 in disk group testdg:
vxpfto -t 50 -g testdg volume01 volume02
Set the PFTO value to 300 seconds on all disks underlying volume01 and volume02, even though they are not in the same disk group:
vxpfto -t 300 volume01 volume02
Disable PFTO on all disks in disk group testdg:
vxpfto -g testdg -o pftostate=disabled
Enable PFTO on all disks underlying volume01 and volume02i in disk group testdg:
vxpfto -g testdg -o pftostate=enabled volume01 volume02
SEE ALSO
vxdisk(1M), pfto(7)
VxVM 5.0.31.1 24 Mar 2008 vxpfto(1M)