Sponsored Content
Operating Systems Solaris 3320 Disk Array Configuration for Oracle 10 Post 302298039 by StarSol on Monday 16th of March 2009 01:04:00 PM
Old 03-16-2009
We are having an issue that Oracle is forcing the host to reboot every once in a while without clear reason in the log. How do you run those commands? When I am connected to the disk array all I see is menu driven tables.
 

10 More Discussions You Might Find Interesting

1. Solaris

LaCie Big Disk configuration on SUN 280R

hi , i am trying to configure LaCie Big Disk on solaris 9 running on a 280R server . i am trying to use the USB prot to connect to the external disk . please i need help on this as i have no clue on how and from where to start . thanks for ur help . cheers (0 Replies)
Discussion started by: ppass
0 Replies

2. Shell Programming and Scripting

bash array passed to oracle

Hi all.. Does anyone know have an example of passing the contents of a bash array to oracle? basically I am looking to loop through the contents of a file(not csv!) and store each line into a bash array. Once i have this I can then pass the array into an oracle procedure that accepts an array... (1 Reply)
Discussion started by: satnamx
1 Replies

3. Solaris

Disk Array

So I have 2 solaris sun servers one with a disk array with 14 drives which I need to move to the other server. How do I move the disk array configured as a Raid 5 to another server without losing data? So far I know I'll connect the drive, run devfsadm, use format to verify the server see's... (5 Replies)
Discussion started by: Kjons76
5 Replies

4. Filesystems, Disks and Memory

Backup Sun StorageTek Common Array Manager's configuration

In Sun manuals, I didn't find how to backup Sun StorageTek Common Array Manager's configuration. Is there a way to do it like backing up Brocade switch configuration? CAM is under Solaris 10. Thank you in advance! (0 Replies)
Discussion started by: aixlover
0 Replies

5. UNIX for Advanced & Expert Users

Disk Array

HI: I have a DUAL redundant system running in HP-UX 10.20 ( 2 servers) Both servers share an external SCSI disk array. Both server runs a Data base wich uses the disk array to write the data, and that is the way they share the information. The way that the servers see the disk array, is like... (1 Reply)
Discussion started by: pmoren
1 Replies

6. Solaris

Can not access storedge 3320 info

Hey guys I am new at Solaris 10, and I'm having a open error on /dev/dsk/c1t1d0s6, when booting. We have a Sunfire v240 running Solaris 10, which is connected to a Storedge 3320, via SCSI. Any help, is appreciated (14 Replies)
Discussion started by: sirkanto
14 Replies

7. Shell Programming and Scripting

Read Oracle connection details from a configuration file

Hi, Is it possible to pass oracle connection information from a configuration file and use that to connect to oracle database in my unix shell scripts. Following is the scenario: (1) I would like to save oracle connection string details in a configuration file (ex., dbconfig.txt) (2) from my... (6 Replies)
Discussion started by: sudhakaratp
6 Replies

8. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

9. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies

10. AIX

Replaced pdisk not showing up in SAS Disk Array Configuration

OSLevel: 5300-10-02-0943 System Model: IBM,8203-E4A Power 6 == Hi! I replaced a failed pdisk in the raid enclosure as follows, - rmdev -l 'pdisk18' '-d' - Replaced it. - cfgmgr (detected) - I can see the new drive, with the correct serial # lscfg -v -l pdisk18 pdisk18... (2 Replies)
Discussion started by: estrar
2 Replies
VTTEST(1)						      General Commands Manual							 VTTEST(1)

NAME
vttest - test VT100-type terminal SYNOPSIS
vttest [options] [24x80.132] DESCRIPTION
Vttest is a program designed to test the functionality of a VT100 terminal (or emulator thereof). It tests both display (escape sequence handling) and keyboard. The program is menu-driven and contains full on-line operating instructions. - To run a given menu-item, you must enter its number. - Menu items start at zero; this is the "Exit" item in almost all cases. - You can run all menu-items (for a given level) by entering an asterisk, i.e, `*'. - You can force a repaint of the menu items by entering "?". - A few menus can be more than one page. Use "n" and "p" to switch to the next or previous page. OPTIONS
You can specify the screen geometry in the form [24x80.132], i.e., 24 lines, 80 minimum columns, 132 maximum columns. If your terminal does not switch between 80 and 132 columns you may specify 24x80.80, for example, to avoid a misleading display. Other options are: -f file specify a file containing a DRCS (soft character definition) string. -l log test results to vttest.log. -p use padding, e.g., for a VT100 connected to a high-speed line. -s add time-delay in selected panning/scrolling options to show details. -8 use 8-bit controls (this can be changed with a menu option). AUTHOR
Per Lindberg (mcvax,seismo)!enea!suadb!lindberg sometime 1985. Modified by Thomas Dickey from June 1996, to support nonstandard screen geometry, VT220-VT520, ISO color and xterm-specific tests. LOCAL VTTEST(1)
All times are GMT -4. The time now is 03:17 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy