Sponsored Content
Operating Systems Solaris 3320 Disk Array Configuration for Oracle 10 Post 302297577 by reborg on Friday 13th of March 2009 07:30:47 PM
Old 03-13-2009
What exactly are the connectivity issues you are having?

What are the outputs for the following commands?

Code:
sccli show-lun
sccli show-channel
show logical-drive
show partition

I can say for sure that your configuration is not a good one for performance, but you have not given enough information to say just how bad it might be.
 

10 More Discussions You Might Find Interesting

1. Solaris

LaCie Big Disk configuration on SUN 280R

hi , i am trying to configure LaCie Big Disk on solaris 9 running on a 280R server . i am trying to use the USB prot to connect to the external disk . please i need help on this as i have no clue on how and from where to start . thanks for ur help . cheers (0 Replies)
Discussion started by: ppass
0 Replies

2. Shell Programming and Scripting

bash array passed to oracle

Hi all.. Does anyone know have an example of passing the contents of a bash array to oracle? basically I am looking to loop through the contents of a file(not csv!) and store each line into a bash array. Once i have this I can then pass the array into an oracle procedure that accepts an array... (1 Reply)
Discussion started by: satnamx
1 Replies

3. Solaris

Disk Array

So I have 2 solaris sun servers one with a disk array with 14 drives which I need to move to the other server. How do I move the disk array configured as a Raid 5 to another server without losing data? So far I know I'll connect the drive, run devfsadm, use format to verify the server see's... (5 Replies)
Discussion started by: Kjons76
5 Replies

4. Filesystems, Disks and Memory

Backup Sun StorageTek Common Array Manager's configuration

In Sun manuals, I didn't find how to backup Sun StorageTek Common Array Manager's configuration. Is there a way to do it like backing up Brocade switch configuration? CAM is under Solaris 10. Thank you in advance! (0 Replies)
Discussion started by: aixlover
0 Replies

5. UNIX for Advanced & Expert Users

Disk Array

HI: I have a DUAL redundant system running in HP-UX 10.20 ( 2 servers) Both servers share an external SCSI disk array. Both server runs a Data base wich uses the disk array to write the data, and that is the way they share the information. The way that the servers see the disk array, is like... (1 Reply)
Discussion started by: pmoren
1 Replies

6. Solaris

Can not access storedge 3320 info

Hey guys I am new at Solaris 10, and I'm having a open error on /dev/dsk/c1t1d0s6, when booting. We have a Sunfire v240 running Solaris 10, which is connected to a Storedge 3320, via SCSI. Any help, is appreciated (14 Replies)
Discussion started by: sirkanto
14 Replies

7. Shell Programming and Scripting

Read Oracle connection details from a configuration file

Hi, Is it possible to pass oracle connection information from a configuration file and use that to connect to oracle database in my unix shell scripts. Following is the scenario: (1) I would like to save oracle connection string details in a configuration file (ex., dbconfig.txt) (2) from my... (6 Replies)
Discussion started by: sudhakaratp
6 Replies

8. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

9. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies

10. AIX

Replaced pdisk not showing up in SAS Disk Array Configuration

OSLevel: 5300-10-02-0943 System Model: IBM,8203-E4A Power 6 == Hi! I replaced a failed pdisk in the raid enclosure as follows, - rmdev -l 'pdisk18' '-d' - Replaced it. - cfgmgr (detected) - I can see the new drive, with the correct serial # lscfg -v -l pdisk18 pdisk18... (2 Replies)
Discussion started by: estrar
2 Replies
did(7)						     Sun Cluster Device and Network Interfaces						    did(7)

NAME
did - user configurable disk id driver DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. Disk ID (DID) is a user configurable pseudo device driver that provides access to underlying disk, tape, and CDROM devices. When the device supports unique device ids, multiple paths to a device are determined according to the device id of the device. Even if multiple paths are available with the same device id, only one DID name is given to the actual device. In a clustered environment, a particular physical device will have the same DID name regardless of its connectivity to more than one host or controller. This, however, is only true of devices that support a global unique device identifier such as physical disks. DID maintains parallel directories for each type of device that it manages under /dev/did. The devices in these directories behave the same as their non-DID counterparts. This includes maintaining slices for disk and CDROM devices as well as names for different tape device behaviors. Both raw and block device access is also supported for disks by means of /dev/did/rdsk and /dev/did/rdsk. At any point in time, I/O is only supported down one path to the device. No multipathing support is currently available through DID. Before a DID device can be used, it must first be initialized by means of the scdidadm(1M) command. IOCTLS
The DID driver maintains an admin node as well as nodes for each DID device minor. No user ioctls are supported by the admin node. The DKIOCINFO ioctl is supported when called against the DID device nodes such as /dev/did/rdsk/d0s2. All other ioctls are passed directly to the driver below. FILES
/dev/did/dsk/dnsm block disk or CDROM device, where n is the device number and m is the slice number /dev/did/rdsk/dnsm raw disk or CDROM device, where n is the device number and m is the slice number /dev/did/rmt/n tape device , where n is the device number /dev/did/admin administrative device /kernel/drv/did driver module /kernel/drv/did.conf driver configuration file /etc/did.conf scdidadm configuration file for non-clustered systems Cluster Configuration Repository (CCscdidadm(1M) maintains configuration in the CCR for clustered systems SEE ALSO
devfsadm(1M), Intro(1CL), cldevice(1CL), scdidadm(1M) NOTES
DID creates names for devices in groups, in order to decrease the overhead during device hot-plug. For disks, device names are created in /dev/did/dsk and /dev/did/rdsk in groups of 100 disks at a time. For tapes, device names are created in /dev/did/rmt in groups of 10 tapes at a time. If more devices are added to the cluster than are handled by the current names, another group will be created. Sun Cluster 3.2 24 April 2001 did(7)