Sponsored Content
Full Discussion: T2000 - devfsadm problem
Operating Systems Solaris T2000 - devfsadm problem Post 302278075 by jfotop on Monday 19th of January 2009 08:07:49 AM
Old 01-19-2009
T2000 - devfsadm problem

Hi everyone,

I am having a problem when running devfsadm. We have many T2000, but on one of them, that is connected to our SAN, devfsadm reports no new disks. If a reconfiguration reboot is done, the system reports the new disk. But only with a reboot. We have Solaris10 installed and Veritas VxVM and emulex LPe11000-M4 (all T2000 we use have the same emulex cards and same firmware revision). We have also checked /kernel/drv/sd.conf and it is exactly the same as on all other working T2000s that use the same cX and targets and LUNs.

The output of cfgadm -al -o show_FCP_dev retrurns:
cfgadm: Configuration administration not supported


#cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 scsi-bus connected configured unknown
c0::dsk/c0t0d0 disk connected configured unknown
c1 scsi-bus connected configured unknown
c1::dsk/c1t0d0 CD-ROM connected configured unknown
usb0/1 unknown empty unconfigured ok
usb0/2 unknown empty unconfigured ok
usb1/1.1 unknown empty unconfigured ok
usb1/1.2 unknown empty unconfigured ok
usb1/1.3 unknown empty unconfigured ok
usb1/1.4 unknown empty unconfigured ok
usb1/2 unknown empty unconfigured ok

Which does not show the other controllers c4,c5
Here is the device path of two SAN disks on this system:
/devices/pci@7c0/pci@0/pci@8/fibre-channel@0/sd@4,0 and
/devices/pci@7c0/pci@0/pci@9/fibre-channel@0/sd@4,0

One other thing I would like to point out, is that we are having the exact same problem on a Sun-Fire-V245 with Solaris9. The only thing that these two servers have in common, as of our system configuration, is that the local system disks are mirrored with hardware RAID. When given the "format" command, this disk is shown as follows:
AVAILABLE DISK SELECTIONS:
0. c0t0d0 <LSILOGIC-LogicalVolume-3000 cyl 65533 alt 2 hd 16 sec 136>
/pci@780/pci@0/pci@9/scsi@0/sd@0,0

Don't know if that has anything to do with this, but I thought I should mention it.

Some general information on the system:
#cat /etc/release
Solaris 10 11/06 s10s_u3wos_10 SPARC
Copyright 2006 Sun Microsystems, Inc. All Rights Reserved.
Use is subject to license terms.
Assembled 14 November 2006
#uname -a
SunOS "hostname" 5.10 Generic_127127-11 sun4v sparc SUNW,Sun-Fire-T200


Any help would be appreciated.

Last edited by jfotop; 01-19-2009 at 09:32 AM..
 

10 More Discussions You Might Find Interesting

1. Solaris

T2000 performance issue

Hi, I have a T2000 box connected to very slow disks (EMC SAN ATA disks) by a double port hba through a fabric topology. RAID 5 (6+1) configuration. The issue is using RMAN for backup and validation psent almost twice the time than with a V880 Fire connected the same way. As with the... (2 Replies)
Discussion started by: freezer91
2 Replies

2. Solaris

t2000 DNS issue

I have an issue with DNS on a solaris t2000 When I set up the zones there was an issue with the /etc/resolv.conf, I had made a typo in my DNS server. I only noticed this after creating my new zones. I have corrected this in the global zone and I am now able to ping and nslookup inthe... (2 Replies)
Discussion started by: james dewitt
2 Replies

3. Linux

devfsadm equivalent(sol) command in linux os

Hi frnds, what is the devfsadm(solaris) equivalent command in linux os? Thanks in Adv. Arjun Reddy. (2 Replies)
Discussion started by: arjunreddy3
2 Replies

4. Solaris

Netra T2000 /var/adm/messages problem

Hi, I have a netra t2000 running solaris 10. It is fully patched with the latest patch cluster and also patch 118833-36 and 126897-02. The SC sys_event level is set to 3. I am running a test to show hardware log status, e.g simulating a power supply failure.Hence I unplug one of te... (3 Replies)
Discussion started by: ulemsee
3 Replies

5. Solaris

SF T2000 prtdiag problem

Hi, a couple of T2000 servers did not show the component status and the output was too short. There was a patch that needed to be installed. I also updated to the latest recommended patch cluster and OBP patch. After reboot/restart of picl, it worked ok for a couple of weeks. Then suddenly it went... (12 Replies)
Discussion started by: incredible
12 Replies

6. Solaris

Auto boot problem on Sun T2000

Hi All I have a problem on T2000 server. bash-3.00# uname -a SunOS 5.10 aaa Generic_120011-14 sun4v sparc SUNW,Netra-T2000After the initial solaris installation server failed to boot: Rebooting with command: boot Boot device: disk:b File and args: The file just loaded does not appear... (1 Reply)
Discussion started by: ouzist
1 Replies

7. Solaris

T2000 Server cannot power on

Hi All, I recently had issues with my new T2000 server. I purchased a new mainboard and swapped the CPU and DIMMs to the new board. Now when i power on the server im unable to do so. I get the following error: ‘SC Alert: Host system poweron failed due to fault at MB/FF_POK.' When i do... (2 Replies)
Discussion started by: Caully
2 Replies

8. Solaris

Raid problem on T2000

Hi all, First post so be gentile :) It's my first time installing Solaris on T2000 server. I have 2 72GB HD's on it. After configuring HW raid and running raidctl command I get this output: bash-3.00# raidctl -l c0t0d0 Volume Size Stripe Status Cache RAID ... (2 Replies)
Discussion started by: Obi-Wan
2 Replies

9. Solaris

dvd problem in T2000

hi all when i trying to give auto-boot value as false as following #eeprom auto-boot?=false it is showing as zsh: no matches found: auto-boot?=false so felt this is because of error in hard ware so i tried this #iostat -en it is showing like iostat -en ---- errors --- s/w h/w trn... (4 Replies)
Discussion started by: wkbn86
4 Replies

10. Solaris

Sun Fire 480 - devfsadm -C not working after replacing one of the boot disks

Our SunFire 480 - one of the boot disks failed. It is mirrored with VxVm. I followed the exact steps that is detailed in the veritas and sun guides (I can not post the URL since I don't have 5 posts yet.) After removing the failed disk, I ran devfsadm -C -c disk and it still shows the device... (7 Replies)
Discussion started by: jtamminen
7 Replies
cfgadm_pci(1M)						  System Administration Commands					    cfgadm_pci(1M)

NAME
cfgadm_pci - PCI Hotplug hardware specific commands for cfgadm SYNOPSIS
/usr/sbin/cfgadm [-f ] [-y | -n ] [-v] [-o hardware_options] -c function ap_id [ap_id] /usr/sbin/cfgadm [-f ] [-y | -n ] [-v] [-o hardware_options] -x hardware_function ap_id [ap_id] /usr/sbin/cfgadm [-v] [-s listing_options] [-o hardware_options] [-l [ ap_id | ap_type]] /usr/sbin/cfgadm [-v] [-o harware_options] -t ap_id [ap_id] /usr/sbin/cfgadm [-v] [-o hardware_function] -h [ ap_id| ap_type] DESCRIPTION
The PCI hardware specific library /usr/lib/cfgadm/pci.so.1 provides the support for hot plugging pci adapter cards into pci hot pluggable slots in a system that is hot plug capable, through the cfgadm command. See cfgadm(1M). For PCI Hot Plug, each hot plug slot on a specific PCI bus is represented by an attachment point of that specific PCI bus. An attachment point consist of two parts: a receptacle and an occupant. The receptacle under PCI hot plug is usually referred to as the physical hot pluggable slot; and the occupant is usually referred to as the PCI adapter card that plugs into the slot. Attachment points are named through ap_ids. There are two types of ap_ids: logical and physical. The physical ap_id is based on the physi- cal pathname, that is, /devices/pci@1/hpc0_slot3, whereas the logical ap_id is a shorter, and more user-friendly name. For PCI hot plug- gable slots, the logical ap_id is usually the corresponding hot plug controller driver name plus the logical slot number, that is, pci0:hpc0slot1; pci nexus driver, with hot plug controller driver named hpc and slot number 1. The ap_type for Hot plug PCI is pci. Note that the ap_type is not the same as the information in the Type field. See the System Administration Guide: Basic Administration for a detailed description of the hot plug procedure. OPTIONS
The following options are supported: -c function The following functions are supported for PCI hot pluggable slots: configure Configure the PCI device in the slot to be used by Solaris. connect Connect the slot to PCI bus. disconnect Disconnect the slot from the PCI bus. insert Not supported. remove Not supported. unconfigure Logically remove the PCI device's resources from the system. -f Not supported. -h ap_id | ap_type Print out PCI hot plug specific help message. -l list List the values of PCI Hot Plug slots. -o hardware_options No hardware specific options are currently defined. -s listing_options Same as the generic cfgadm(1M). -t ap_id This command is only supported on platforms which support testing capability on the slot. -v Execute in verbose mode. When -v is used with -l option the cfgadm command outputs information about the attachment point. For PCI Hot Plug, the Information field will be the slot's system label. This string will be obtained from the slot-name property of the slot's bus node. The information in the Type field is printed with or without the -v option. The occupant Type field will describe the contents of the slot. There are 2 possible values: unknown The slot is empty. If a card is in the slot, the card is not configured or there is no driver for the device on the card. subclass/board The card in the slot is either a single-function or multi-function device. subclass is a string representing the subclass code of the device, for example, SCSI, ethernet, pci-isa, and so forth. If the card is a multi-functional device, MULT will get printed instead. board is a string representing the board type of the device. For example, hp is the string used for a PCI Hot Plug adapter, hs is used for a Hot Swap Board, nhs for a Non--Hot Swap cPCI Board, bhs for a Basic Hot Swap cPCI Board, and fhs for a Full Hot Swap cPCI Board. Most pci cards with more than one device are not multi-function devices, but are implemented as a pci bridges with arbitrary devices behind them. In those cases, the subclass displayed is that of the pci bridge. Most com- monly the bridges are pci-pci, a generic pci to pci bridge or stpci, a semi-transparent pci bridge. -x hardware_function Perform hardware specific function. These hardware specific functions should not normally change the state of a receptacle or occupant. The following hardware_functions are supported: enable_slot | disable_slot Change the state of the slot and preserve the state of slot across reboot. Preservation of state across reboot is only supported on select platforms. enable_slot enables the addition of hardware to this slot for hot plugging and at boot time. disable_slot disables the addition of hardware to this slot for hot plugging and at boot time. When a slot is disabled its condi- tion is shown as unusable. enable_autoconfig | disable_autoconfig Change the ability to autoconfigure the occupant of the slot. Only platforms that support auto configuration support this feature. enable_autoconfig enables the ability to autoconfigure the slot. diable_autoconfig disables the ability to autoconfigure the slot. led=[led_sub_arg],mode=[mode_sub_arg] Without sub-arguments, print a list of the current LED settings. With sub-arguments, set the mode of a specific LED for a slot. Specify led_sub_arg as fault, power, att, or active. Specify mode_sub_arg as on, off or blink. Changing the state of the LED does not change the state of the receptacle or occupant. Normally, the LEDs are controlled by the hot plug controller, no user intervention is necessary. Use this command for testing purposes. Caution: Changing the state of the LED can misrepresent the state of occupant or receptacle. The following command prints the values of LEDs: example# cfgadm -x led pci0:hpc0_slot1 Ap_Id Led pci0:hpc0_slot1 power=on,fault=off,active=off,attn=off The following command turns on the Fault LED: example# cfgadm -x led=fault,mode=on pci0:hpc0_slot1 The following command turns off the Power LED: example# cfgadm -x led=power,mode=off pci0:hpc0_slot0 The following command sets the active LED to blink to indicate the location of the slot: example# cfgadm -x led=active,mode=on pci0:hpc0_slot3 EXAMPLES
Example 1: Printing out the Value of Each Slot The following command prints out the values of each slot: example# cfgadm -l Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c1 scsi-bus connected unconfigured unknown c2 scsi-bus connected unconfigured unknown cpci_slot1 stpci/fhs connected configured ok cpci_slot2 unknown empty unconfigured unknown cpci_slot4 stpci/fhs connected configured ok cpci_slot5 stpci/fhs connected configured ok Example 2: Replacing a Card The following command lists all DR-capable attachment points: example# cfgadm Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c1 scsi-bus connected unconfigured unknown c2 scsi-bus connected unconfigured unknown cpci_slot1 stpci/fhs connected configured ok cpci_slot2 unknown empty unconfigured unknown cpci_slot4 stpci/fhs connected configured ok cpci_slot5 stpci/fhs connected configured ok The following command unconfigures and electrically disconnects the card: example# cfgadm -c disconnect cpci_slot4 The change can be verified by entering the following command: example# cfgadm cpci_slot4 Ap_Id Type Receptacle Occupant Condition cpci_slot4 unknown disconnected unconfigured unknown Now the card can be swapped. The following command electrically connects and configures the card: example# cfgadm -c configure cpci_slot4 The change can be verifed by entering the following command: example# cfgadm cpci_slot4 Ap_Id Type Receptacle Occupant Condition cpci_slot4 stpcipci/fhs connected configured ok FILES
/usr/lib/cfgadm/pci.so.1 Hardware specific library for PCI hot plugging. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWkvm.u | +-----------------------------+-----------------------------+ SEE ALSO
cfgadm(1M), config_admin(3CFGADM), libcfgadm(3LIB), attributes(5) System Administration Guide: Basic Administration SunOS 5.10 27 Oct 2003 cfgadm_pci(1M)
All times are GMT -4. The time now is 06:10 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.