12-05-2008
Quote:
Originally Posted by
samar
Hi grus,
has anybody tried for Sun cluster interconnect normal cable ,, I mean not interconnect .. What do u think ..does it support this ?
Not long ago I tried Veritas cluster and its interconnections work great with normal cable .. I wonder what will Sun cluster say to it
)
on what kind of hardware do you try veritas cluster? modern hardware does a "autocrossover" even with a normal patch cable. so i think this is a hardware function and has nothing to do with the cluster software...
9 More Discussions You Might Find Interesting
1. High Performance Computing
Dear All,
Can anyone explain about Pros and Cons of SUN and Veritas Cluster ?
Any comparison chart is highly appreciated.
Regards,
RAA (4 Replies)
Discussion started by: RAA
4 Replies
2. IP Networking
Hi,
I'm trying to communicate two servers (HP DLProliant 380 G5) via a crossover cable, but I don't get them to ping each other.
I am working in RHEL 4.
These are the steps I've performed:
1) Plugged the crossover cables in eth2.
(note: The cable is brand new. Also I built one myself... (3 Replies)
Discussion started by: jrodriguez365
3 Replies
3. Solaris
Yesterday my customer told me to expect a vcs upgrade to happen in the future. He also plans to stop using HDS and move to EMC.
Am thinking how to migrate to sun cluster setup instead.
My plan as follows leave the existing vcs intact as a fallback plan.
Then install and build suncluster on... (5 Replies)
Discussion started by: sparcguy
5 Replies
4. Solaris
Hello
I have problem with scinstall. I found information that i should`t configure public network before using scinstall.
Each node configuration:
4 node, 3 network adapter on each node. 1 for public adapter and 2 for cluster interconnect. Two switches.
After scinstall first node is... (1 Reply)
Discussion started by: time0ut
1 Replies
5. Solaris
Any body can tell me where i can download sun cluster installation and configuration video.
is there any option to install cluster in 32 bit virtual machine.
please help (4 Replies)
Discussion started by: sunnybee
4 Replies
6. Solaris
Hi all,
I have application running on sun server T5440 4x8x1.4 GHz, 64 GB RAM, application running very slow though load average too low. when I install my application on another server SUN M3000 (One CPU 1x8x2.5GHz, 8GB RAM), application run smoothly.
Here is my server T5440 info:
... (6 Replies)
Discussion started by: insatiable1610
6 Replies
7. Solaris
Hello experts -
I am planning to install a Sun cluster 4.0 zone cluster fail-over. few basic doubts.
(1) Where should i install the cluster s/w binaries ?. ( global zone or the container zone where i am planning to install the zone fail-over)
(2) Or should i perform the installation on... (0 Replies)
Discussion started by: NVA
0 Replies
8. Hardware
Hello,
I have a spare SUN server X4200 with a DC PSU (oracle part number 300-2186)
The PSU is the one in the photo
I was looking in the net about what cable i can order but i couldn't find anything that fit there :)
Any idea?
Thanks! (2 Replies)
Discussion started by: @dagio
2 Replies
9. Solaris
Running Sun Cluster v3.2 it appears. Two clustered physcial servers both running Solaris 10.
Both servers run a number of Oracle DBs etc. BUT I'm a bit concerned that its been set up but will never switch in the even of failure of one of the hosts?
Some of the cluster groups we've... (3 Replies)
Discussion started by: psychocandy
3 Replies
LEARN ABOUT OPENSOLARIS
scconf_transp_adap_ce
scconf_transp_adap_ce(1M) System Administration Commands scconf_transp_adap_ce(1M)
NAME
scconf_transp_adap_ce - configure the ce Sun Ethernet transport adapter
DESCRIPTION
Note -
Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software
still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor-
mation about the object-oriented command set, see the Intro(1CL) man page.
You can configure ce adapters as cluster transport adapters. These adapters can be used with transport types dlpi. The ce adapter is VLAN
capable.
A ce adapter connects to a transport switch or to another ce adapter on a different node. In either case, the connection is made through a
transport cable.
When a transport switch is used and the endpoints of the transport cable are configured by using scconf, scinstall, or other tools, you are
asked to specify a port name on the transport switch. You can provide any port name, or accept the default, as long as the name is unique
for the switch.
The default is to set the port name to the node ID hosting the adapter at the other end of the cable.
There are no user configurable properties for cluster transport adapters of this type.
SEE ALSO
Intro(1CL), clinterconnect(1CL), clnode(1CL), scconf(1M), scinstall(1M), ce(7D)
Sun Cluster 3.2 4 May 2006 scconf_transp_adap_ce(1M)