Sponsored Content
Full Discussion: Printing queue in rs6000
Operating Systems AIX Printing queue in rs6000 Post 302264199 by bakunin on Wednesday 3rd of December 2008 11:12:33 AM
Old 12-03-2008
To find out if you have enough diskspace you do not need to know the size of your actual LVs but the size of your disks. Issue "lsvg rootvg" and "lsvg -p rootvg" to see how much diskspace you have:

"lsvg rootvg" will tell you the PP size, "lsvg -p rootvg" will tell you how many PPs on all the disks in the rootvg exist.

If you have a mirrored rootvg (this is not shown in the "df -k") you can consider a "alternate disk migration". In short this is: split the mirror of the rootvg, update the one while retaining the other as a backup copy. In case everything works fine remirror the newly installed half, otherwise remirror the withheld half. We have some threads here regarding alternate disk migration, you might want to read them and ask if you have questions regarding this.

Having not much time right now i have to stop here. Maybe someone else can explain the firmware update procedures (preferably in detail, so we could turn that into a FAQ), otherwise i will come back to this later.

I hope this helps.

bakunin
 

10 More Discussions You Might Find Interesting

1. Programming

Good IDE for C++ on RS6000/AIX

I am looking for the above Can anyone point me to a reliable product, with available support in the forseeable future ? Seeker (0 Replies)
Discussion started by: Seeker
0 Replies

2. AIX

RS6000 SSA Raid question

Hi Can I add disks on the fly to extend the capacity of an existing RAID 5 volume? It's created on a 4P Advanced SSA Raid Adapter. I need to extend a volume group, so I figured it would be easiest to extend the "physical disk" which is a RAID5 volume. Thanks. (1 Reply)
Discussion started by: osee
1 Replies

3. AIX

Printing multiple copies via remote queue

Hi all, I have an interesting problem. Using remote queues to print using jetdirect printers I am unable to get a printer to print multiple copies of a print job. command being used: lpr -P -#3 ./test (one copy prints) Also tried: enq -P -C3 ./test (same results) Any ideas? ... (6 Replies)
Discussion started by: Luck
6 Replies

4. AIX

Re-Installation of AIX 5.2 in RS6000 7026

Hi There!! I need to reinstall the operating system AIX 5.2 in a RS6000 7026/6H1 that has AIX 4.3 but I need a firmware upgrade that I dón´t know where can I obtain. - Platform firmware version 3 or later. Someone can help me please, I will be very grateful !! Thank´s. (1 Reply)
Discussion started by: terron79
1 Replies

5. AIX

New to AIX and got my hands on a RS6000 v.need help getting it on the network

So im fairly new to AIX and my knowledge is very, very limited but i got my hands on an RS6000 43P model and im trying to get it on the network so i can access it from work. I have pretty much tried everything i can/know how to do by reading up as much as i can but im still lost. I have the 43P... (2 Replies)
Discussion started by: IIIII
2 Replies

6. AIX

VNC or X Emulator on RS6000 AIX 5.2

Hello everyone, I have just joined your forum even though I have been using it on and off for couple of months now. Up until now I have been able to find any information I needed by just browsing this site or performing a Google search, but now I'm stuck!. I was hoping you could help me with... (16 Replies)
Discussion started by: juniorG
16 Replies

7. AIX

Reinstalling AIX 4.3 on IBM RS6000

Hey guys, I'm a newbie in Unix world.. Currently in my office lies an old IBM RS6000 which hasn't been maintained for a very long time. The former admin has resigned and we don't have any documentation or whatsoever regarding the old machine. All I know that it is an RS6000 is because of what's... (4 Replies)
Discussion started by: arch4ng3l
4 Replies

8. AIX

Remote printing to Linux CUPS queue

Hello all. I am setting up a queue under AIX 4.2.1 to print to a remote Linux CUPS queue. At present I can print to the queue remotely from Windows but not AIX. What I am seeing is lpstat reads the state of the remote queue but at job submission time I am getting backend exit fatal errors. The... (4 Replies)
Discussion started by: tgx
4 Replies

9. UNIX for Dummies Questions & Answers

Sco Unix printing : jobs hangs in queue - printing via lp versus hpnpf

Hi, We have a Unix 3.2v5.0.5. I installed a printer via scoadmin, HP network printer manager with network peripheral name (hostname and ipadres are in /etc/hosts). This is the configuration file : Code: root@sco1 # cat configurationBanner: on:AlwaysContent types: simpleDevice:... (0 Replies)
Discussion started by: haezeban
0 Replies

10. AIX

AIX 5.1 and RS6000

I've an old server 1996 RS6000 (Processor 604e) running AIX 5.1. It started up fine, booted up and connected on 10Mbit with my router. I used to be able to connect to it with telnet but not anymore. I know the IP is right but working with the smit tcpip options, looks like I've changed... (1 Reply)
Discussion started by: Devyn
1 Replies
CCD(4)							   BSD Kernel Interfaces Manual 						    CCD(4)

NAME
ccd -- Concatenated Disk driver SYNOPSIS
device ccd DESCRIPTION
The ccd driver provides the capability of combining one or more disks/partitions into one virtual disk. This document assumes that you are familiar with how to generate kernels, how to properly configure disks and devices in a kernel configura- tion file, and how to partition disks. In order to compile in support for the ccd, you must add a line similar to the following to your kernel configuration file: device ccd # concatenated disk devices As of the FreeBSD 3.0 release, you do not need to configure your kernel with ccd but may instead use it as a kernel loadable module. Simply running ccdconfig(8) will load the module into the kernel. A ccd may be either serially concatenated or interleaved. To serially concatenate the partitions, specify the interleave factor of 0. Note that mirroring may not be used with an interleave factor of 0. There is a run-time utility that is used for configuring ccds. See ccdconfig(8) for more information. The Interleave Factor If a ccd is interleaved correctly, a ``striping'' effect is achieved, which can increase sequential read/write performance. The interleave factor is expressed in units of DEV_BSIZE (usually 512 bytes). For large writes, the optimum interleave factor is typically the size of a track, while for large reads, it is about a quarter of a track. (Note that this changes greatly depending on the number and speed of disks.) For instance, with eight 7,200 RPM drives on two Fast-Wide SCSI buses, this translates to about 128 for writes and 32 for reads. A larger interleave tends to work better when the disk is taking a multitasking load by localizing the file I/O from any given process onto a single disk. You lose sequential performance when you do this, but sequential performance is not usually an issue with a multitasking load. An interleave factor must be specified when using a mirroring configuration, even when you have only two disks (i.e., the layout winds up being the same no matter what the interleave factor). The interleave factor will determine how I/O is broken up, however, and a value 128 or greater is recommended. ccd has an option for a parity disk, but does not currently implement it. The best performance is achieved if all component disks have the same geometry and size. Optimum striping cannot occur with different disk types. For random-access oriented workloads, such as news servers, a larger interleave factor (e.g., 65,536) is more desirable. Note that there is not much ccd can do to speed up applications that are seek-time limited. Larger interleave factors will at least reduce the chance of having to seek two disk-heads to read one directory or a file. Disk Mirroring You can configure the ccd to ``mirror'' any even number of disks. See ccdconfig(8) for how to specify the necessary flags. For example, if you have a ccd configuration specifying four disks, the first two disks will be mirrored with the second two disks. A write will be run to both sides of the mirror. A read will be run to either side of the mirror depending on what the driver believes to be most optimal. If the read fails, the driver will automatically attempt to read the same sector from the other side of the mirror. Currently ccd uses a dual seek zone model to optimize reads for a multi-tasking load rather than a sequential load. In an event of a disk failure, you can use dd(1) to recover the failed disk. Note that a one-disk ccd is not the same as the original partition. In particular, this means if you have a file system on a two-disk mir- rored ccd and one of the disks fail, you cannot mount and use the remaining partition as itself; you have to configure it as a one-disk ccd. You cannot replace a disk in a mirrored ccd partition without first backing up the partition, then replacing the disk, then restoring the partition. Linux Compatibility The Linux compatibility mode does not try to read the label that Linux' md(4) driver leaves on the raw devices. You will have to give the order of devices and the interleave factor on your own. When in Linux compatibility mode, ccd will convert the interleave factor from Linux terminology. That means you give the same interleave factor that you gave as chunk size in Linux. If you have a Linux md(4) device in ``legacy'' mode, do not use the CCDF_LINUX flag in ccdconfig(8). Use the CCDF_NO_OFFSET flag instead. In that case you have to convert the interleave factor on your own, usually it is Linux' chunk size multiplied by two. Using a Linux RAID this way is potentially dangerous and can destroy the data in there. Since FreeBSD does not read the label used by Linux, changes in Linux might invalidate the compatibility layer. However, using this is reasonably safe if you test the compatibility before mounting a RAID read-write for the first time. Just using ccdconfig(8) without mounting does not write anything to the Linux RAID. Then you do a fsck.ext2fs (ports/sysutils/e2fsprogs) on the ccd device using the -n flag. You can mount the file system read-only to check files in there. If all this works, it is unlikely that there is a problem with ccd. Keep in mind that even when the Linux compatibility mode in ccd is working correctly, bugs in FreeBSD's ex2fs implemen- tation would still destroy your data. WARNINGS
If just one (or more) of the disks in a ccd fails, the entire file system will be lost unless you are mirroring the disks. If one of the disks in a mirror is lost, you should still be able to back up your data. If a write error occurs, however, data read from that sector may be non-deterministic. It may return the data prior to the write or it may return the data that was written. When a write error occurs, you should recover and regenerate the data as soon as possible. Changing the interleave or other parameters for a ccd disk usually destroys whatever data previously existed on that disk. FILES
/dev/ccd* ccd device special files SEE ALSO
dd(1), ccdconfig(8), config(8), disklabel(8), fsck(8), gvinum(8), mount(8), newfs(8) HISTORY
The concatenated disk driver was originally written at the University of Utah. BSD
August 9, 1995 BSD
All times are GMT -4. The time now is 09:29 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy