Sponsored Content
Full Discussion: AIX 5.3 error code 11007611
Operating Systems AIX AIX 5.3 error code 11007611 Post 302259374 by zaxxon on Tuesday 18th of November 2008 01:00:16 AM
Old 11-18-2008
Do a firmware update maybe.
 

10 More Discussions You Might Find Interesting

1. AIX

Return Code of tar in AIX

I am making some shell commands using tar command under AIX. Could somebody tell me the meaning of those return code of tar command? like 1, 2, 3... I have been searching all the time and got only this: 0 success >0 error Does somebody know the meaning of those number greater than 0 in... (3 Replies)
Discussion started by: dupeng
3 Replies

2. Programming

Does anyone have example code for getting File System info on AIX

I'm looking for example C source of how to get file system information on AIX systems. Does anyone have anything? (3 Replies)
Discussion started by: StuBob
3 Replies

3. Programming

Code working AIX 5.2 and not in Solaris 5.9

Hi, When i run the below code in AIX it runs and solaris not ... why ??? #include <stdio.h> #include <string.h> #define MAX 1 int main () { char str ="1,2,3,4,5"; char * pch,b; int a; printf ("Enter the int to be searched ",str); scanf("%d",&a); sprintf(b,"%d",a); ... (2 Replies)
Discussion started by: vijaysabari
2 Replies

4. AIX

AIX 4.3.3 boot error code 0555

Hi All, I have a machine(pSeries 7602-6H1) with AIX 4.3.3 installed. When i try to power it on, it moves through the boot sequence till it gets to closing stdin and stdout. From that point onwards, the diagnostic display moves until it gets to 0555 then the system stays there. Any ideas... (2 Replies)
Discussion started by: ayigbe
2 Replies

5. UNIX for Advanced & Expert Users

Porting linux ftpd code to Aix

Dear All, I have already ported the linux ftpd daemon to AIX earlier. When the ftp client does a "DIR" command, I have intercepted the call to the remote machine at the server code and added my code to browse IBM Message Queue, so that the client will see the files in the IBM Message... (2 Replies)
Discussion started by: srksn
2 Replies

6. AIX

Issue "Error 404" when upgrade AIX 5300-05-CSP-0000 to AIX (5300-09-02-0849)

Please read my issue! My old server using: - AIX system operating (5300-05-CSP-0000) - WebSphere 6.1.0.21 (Fix Pack 21) After I've upgraded version AIX - AIX system operating (5300-09-02-0849) - WebSphere 6.1.0.21 (Fix Pack 21) I have 1 issue when I access home page: "Error... (0 Replies)
Discussion started by: gamonhon
0 Replies

7. AIX

aix 4.2: finding out the return code of a savevg/mksysb ?

Am I right to assume that to check the return code of a savevg/mksysb on an AIX 4.2 is with the "$?" ? (1 Reply)
Discussion started by: Browser_ice
1 Replies

8. AIX

Segmentation fault in nsgetcinfo in aix 64-bit c code

Hello, I am running on a AIX5.2 server with Oracle 10g and 9i. My code compiles and works fine in 32-bit mode. The same code compiles in 64-bit and runs good. The program catches CNTRL-C signal to terminate. Only on 64-bit code when i hit CNTRL-C, the program exits with segmentation... (0 Replies)
Discussion started by: sumesh0710
0 Replies

9. Shell Programming and Scripting

error code 137 and error code 35072

Hi while trying to run few scripts /afs/ae.ge.com/informatica/ardw/dev/bin/cdw_ar_update_recvbal.sh this script contains the below data load_dir=/afs/ae.ge.com/informatica/ardw/dev/data prog_dir=/afs/ae.ge.com/informatica/ardw/dev/bin ctl_dir=/afs/ae.ge.com/informatica/ardw/dev/ctl... (1 Reply)
Discussion started by: laxmi131
1 Replies

10. Shell Programming and Scripting

shell script returning error code 2 from AIX to Mainframe

Hi, I have a shell script which is residing on AIX which is triggered by Mainframe through Connect Direct. The shell script creates several files and sends those files to mainframe using Connect Direct. The shell script is working fine, still it is returning exit code 2 to mainframe. What... (0 Replies)
Discussion started by: Yogesh Aggarwal
0 Replies
DBCOOL(4)						   BSD Kernel Interfaces Manual 						 DBCOOL(4)

NAME
dbcool, adm1027, adm1030, adm1031, adt7463, adt7466, adt7467, adt7468, adt7473, adt7475, adt7476, adt7490, emc6d103s -- dbCool(tm) family of environmental monitors and fan controllers SYNOPSIS
dbcool* at ki2c? dbcool* at iic? addr 0x2e DESCRIPTION
The dbcool driver provides support for the Analog Devices dbCool and the SMSC EMC6D103S environmental monitor chips to be used with the envsys(4) API. These chips support up to fifteen sensors. Not all of the following sensors are supported on all chips. Sensor Units Typical Use l_temp uK local chip temperature r1_temp uK CPU temperature r2_temp uK GPU temperature Vccp uV DC CPU Vcore Vcc uV DC Chip's supply voltage 2.5V uV DC 2.5V supply 5V uV DC 5V supply 12V uV DC 12V supply Vtt uV DC PECI ref. voltage (2.25V ref, ADT7490 only) Imon uV DC Current monitor (2.25V ref, ADT7490 only) AIN1 uV DC Analog In (2.25V ref, ADT7466 only) AIN2 uV DC Analog In (2.25V ref, ADT7466 only) fan1 RPM Chassis Fan fan2 RPM Chassis Fan fan3 RPM Chassis Fan fan4 RPM Chassis Fan VID (none) CPU VID code (selected chips only) Each temperature and voltage sensor has programmable hardware high- and low-limits; fan sensors have only a low-limit. These limits can be set using the envstat(8) utility. Due to hardware limitations, the minimum permissible value for the fan speed low-limits is 83 RPM. Temperature sensors also have Tmin, Trange, Thyst, and Ttherm sysctl(8) variables; these values are used by the fan speed controllers. Their values are in units of degC, since this is the unit which is programmed into the device registers. All members of the dbCool family support Pulse-Width Modulated (PWM) fan speed control based on temperature thresholds - the fan will spin up when its associated thermal sensor(s) exceeds its configured Tmin value. The fan will go faster as the temperature rises, and will slow down as the temperature falls. If the temperature exceeds the sensor's Ttherm value, the THERM signal will be asserted, and if enabled the fan will run at full speed. The fan will be turned off when the sensor(s) that triggered it reports a temperature which is at least Thyst degrees below its Tmin threshold. Each fan controller is programmable using the following sysctl(8) variables. hw.dbcool0.fan_ctl_0.behavior hw.dbcool0.fan_ctl_0.min_duty hw.dbcool0.fan_ctl_0.max_duty hw.dbcool0.fan_ctl_0.cur_duty The behavior variable controls the selection of temperature sensors associated with the fan controller. When the associated temperature sen- sor reaches its Tmin value, the fan controller starts the fan at its minimum duty cycle; when the associated temperature sensor reaches its Ttherm value and asserts the THERM signal (or if an external THERM signal is asserted), the fan controller sets the fan speed to a 100% duty cycle. Between these two settings, each temperature sensor is used to calculate a duty cycle linearly based on the slope defined by the tem- perature sensor's range variable. When the associated temperature falls at least Thyst degress below its Tmin value, the fan controller will turn off the fan. (On the ADM1030, the value for Thyst is fixed at 5 degC.) Valid values for the behavior variable are: local (not available on ADM1030) remote1 remote2 (not available on ADM1030) local+remote2 (not available on ADM1030) all-temps full-speed (not available on ADM1030) manual disabled When the behavior variable is set to ``manual'', the cur-duty variable becomes user-writable and can be set to any value between 0 and 100 inclusive to control the fan's duty cycle manually. In all other behavior modes, the cur-duty variable is read-only and updates are ignored. The min-duty and max-duty variables define the range over which the fan controller will manage the fan's duty cycle. On the ADM1030, these values are not separately controllable. The max-duty is fixed at 100%, and the cur-duty variable is used to specify the minimum duty cycle when the fan controller is running in automatic mode. Note that the duty-cycle value does not directly correspond to the fan's speed. That is, a 33% duty cycle does not mean that the fan runs at 33% of its maximum speed; in actuality, a 33% duty cycle drives the fan at a speed close to 50% of its maximum. Fan speed correlates approx- imately to the square root of the duty cycle. EXAMPLES
The envstat(8) utility can be used to determine the sensors supported: Current CritMax WarnMax WarnMin CritMin Unit l_temp: 44.250 degC r1_temp: 41.250 degC r2_temp: N/A Vccp: 0.002 V Vcc: 3.351 V fan1: N/A fan2: N/A fan3: N/A fan4: N/A Using this information, the following commands in /etc/envsys.conf will set appropriate limits for CPU temperature and chip supply voltage, and powerd will be notified if the limits are exceeded: dbcool0 { sensor1 { warning-max = 60C; critical-max = 65C; } sensor4 { critical-min = 3.1; warning-min = 3.2; critical-max = 3.5; } } SEE ALSO
envsys(4), iic(4), envstat(8), powerd(8), sysctl(8) HISTORY
The dbcool device appeared in NetBSD 5.0. BUGS
Although the sensor limit registers can be programmed, there is currently no use of the dbCool chips' ability to generate an SMBus interrupt when the limits are exceeded. Limit checking and event generation are done in software, and are performed only when the sensor values are polled and refreshed. The ADT7466 chip, although officially a member of the dbCool family, is programmed quite differently. The fan controllers on this chip are not currently implemented. The PECI (Processor Environment Control Interface) temperature sensors and the associated PWM behavior modes on the ADT7490 are not currently supported. BSD
March 12, 2011 BSD
All times are GMT -4. The time now is 09:45 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy