Sponsored Content
Operating Systems Solaris Resyncing Progress of hardware mirror Post 302253367 by Chains on Friday 31st of October 2008 11:47:35 AM
Old 10-31-2008
Resyncing Progress of hardware mirror

Hi,

I've recently mirrored the 4 disks in a V440. Disks 0 + 1 have been mirrored with hardware mirroring using the command raidctl -c c1t0d0 c1t2d0, the other 2 disks have been mirrored using Soltisce Disk Suite. I know how to check the progress for the SDS mirroring but how can I find the progreess of the hardware mirror as the raidctl -l command shows the output below, but doesn't show the percentage complete. I'm sure this must be possible to find out?

[root@*****-****] # raidctl -l
RAID RAID RAID Disk
Volume Status Disk Status
------------------------------------------------------
c1t0d0 RESYNCING c1t0d0 OK
c1t1d0 OK

Thanks

Chains
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Checking cp progress

Hi gurus. I wonder if there is some command that will help me to determing the progress of cp. I'm copying huge amount of files, and through the ps x -uoracle see, that it goes 1771 pts/6 S+ 0:37 cp 1_2600_617913793.arc 37 minutes. Is there command, that helps determing on what... (0 Replies)
Discussion started by: MarGur
0 Replies

2. Shell Programming and Scripting

Progress

Maybe someone know how to create something like "*". If someone uses Gentoo he must see this while emerge utility preparing an update. I mean the symbol "/" spins. (2 Replies)
Discussion started by: mirusnet
2 Replies

3. Shell Programming and Scripting

progress bar

hi all, in shell script (ksh), how do i write a progress bar ?? i have a script which searches files and while its searching i am currently printing out "." and if it finds what its searching for the script prints out the name of the file e.g .................. firstFile.txt... (2 Replies)
Discussion started by: cesarNZ
2 Replies

4. Solaris

ZFS Mirror versus Hardware Mirror

I've looked a little but haven't found a solid answer, assuming there is one. What's better, hardware mirroring or ZFS mirroring? Common practice for us was to use the raid controllers on the Sun x86 servers. Now we've been using ZFS mirroring since U6. Any performance difference? Any other... (3 Replies)
Discussion started by: Lespaul20
3 Replies

5. Solaris

What is mirror and sub mirror in RAID -1 SVM

Hi , I am new to SVM .when i try to learn RAID 1 , first they are creating two RAID 0 strips through metainit d51 1 1 c0t0d0s2 metainit d52 1 1 c1t0d0s2 In the next step metainit d50 -m d51 d50: Mirror is setup next step is metaattach d50 d52 d50 : submirror d52 is... (7 Replies)
Discussion started by: vr_mari
7 Replies

6. Emergency UNIX and Linux Support

mdadm unable to fail a resyncing drive?

Hi All I have a RAID 5 array consisting of 4 drives that had a partial drive failure in one of the drives. Rebooting shows the faulty drive as background rebuilding and mdadm /dev/ARRAYID shows three drives as in sync with the fourth drive as spare rebuilding. However the array won't come... (9 Replies)
Discussion started by: Bashingaway
9 Replies

7. Solaris

Hardware faulty, but which hardware?

Hi folk, I have this hardware faunty message, but dont know which hardware is this ? can you guide me ? --------------- ------------------------------------ -------------- --------- TIME EVENT-ID MSG-ID SEVERITY ---------------... (9 Replies)
Discussion started by: dehetoxic
9 Replies

8. HP-UX

What is the difference between DRD and Root Mirror Disk using LVM mirror ?

what is the difference between DRD and Root Mirror Disk using LVM mirror ? (3 Replies)
Discussion started by: maxim42
3 Replies

9. Solaris

Maint, resyncing and last-erred notifications

Hi fellow members! I have a oracle solaris server with two internal disks, that acts as an authentication server only, and for now the server seems to be doing its job, but when typing metastat -c I get some notifications. I am not familiar with SVM, I wonder if someone can help me on this:... (3 Replies)
Discussion started by: fretagi
3 Replies
MFI(4)							   BSD Kernel Interfaces Manual 						    MFI(4)

NAME
mfi -- LSI Logic & Dell MegaRAID SAS RAID controller SYNOPSIS
mfi* at pci? dev ? function ? DESCRIPTION
The mfi driver provides support for the MegaRAID SAS family of RAID controllers, including: - Dell PERC 5/e, PERC 5/i, PERC 6/e, PERC 6/i - Intel RAID Controller SRCSAS18E, SRCSAS144E - LSI Logic MegaRAID SAS 8208ELP, MegaRAID SAS 8208XLP, MegaRAID SAS 8300XLP, MegaRAID SAS 8308ELP, MegaRAID SAS 8344ELP, MegaRAID SAS 8408E, MegaRAID SAS 8480E, MegaRAID SAS 8708ELP, MegaRAID SAS 8888ELP, MegaRAID SAS 8880EM2, MegaRAID SAS 9260-8i - IBM ServeRAID M1015, ServeRAID M5014 These controllers support RAID 0, RAID 1, RAID 5, RAID 6, RAID 10, RAID 50 and RAID 60 using either SAS or SATA II drives. Although the controllers are actual RAID controllers, the driver makes them look just like SCSI controllers. All RAID configuration is done through the controllers' BIOSes. mfi supports monitoring of the logical disks in the controller through the bioctl(8) and envstat(8) commands. EVENTS
The mfi driver is able to send events to powerd(8) if a logical drive in the controller is not online. The state-changed event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens. SEE ALSO
intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8) HISTORY
The mfi driver first appeared in NetBSD 4.0. BSD
March 22, 2012 BSD
All times are GMT -4. The time now is 04:25 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy