Operating Systems Solaris Dat72 SUN Post 302253361 by incredible on Friday 31st of October 2008 11:37:57 AM
Old 10-31-2008
1st perform a boot -r and do a mt stat and see if the drive/tape is detected.
Just do a devfsadm -C and re-check. If problem persists, let us know the Solaris OS version (IS THIS A DUPLICATE QUESTION ????)
 

6 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Help: Sun Disk partitioning for Sun V240 & StorEdge 3300

Dear Sun gurus, I have Sun Fire V240 server with its StorEdge 3300 disk-array. Following are its disks appeared in format command. I have prepared its partitions thru format and metainit & metattach (may be i have made wrong steps, causing the errors below because I have done thru some document... (1 Reply)
Discussion started by: shafeeq
1 Replies

2. UNIX for Dummies Questions & Answers

Sun Solaris 10: How do I create a bootup disc? The Sun website confuses me

Hey there, I am starting a Computer Science Foundation year at the end of this month and am trying to get a little bit ahead of the game. I have always wanted to learn Unix and am currently struggling with creating a boot disc to run Solaris (I have chosen to study this) from as opposed to... (0 Replies)
Discussion started by: Jupiter
0 Replies

3. Solaris

dat72 Drive

Hi All, Installing a dat72 tape drive on a server with Solaris 7 on it. OS not recognising it even with the latest recommended patch cluster. Anyone know the parameters for st.conf? Thanks Martin (0 Replies)
Discussion started by: callmebob
0 Replies

4. Solaris

Usb dat72

Hi All, How to mount a USB dat72 into V490 solaris 9? Can this work and do backup? I only use scsi dat72 before and it work on all platform. but USB dat72 is for window? Please advice. (1 Reply)
Discussion started by: mailbox80
1 Replies

5. Solaris

Sun Fire 280R Sun Solaris CRT/Monitor requirements

I am new to Sun. I brought Sun Fire 280R to practice UNIX. What are the requirements for the monitor/CRT? Will it burn out old non-Sun CRTs? Does it need LCD monitor? Thanks. (3 Replies)
Discussion started by: bramptonmt
3 Replies

6. Solaris

Application running too slow on Sun SPARC T5440 but run normal on sun M3000

Hi all, I have application running on sun server T5440 4x8x1.4 GHz, 64 GB RAM, application running very slow though load average too low. when I install my application on another server SUN M3000 (One CPU 1x8x2.5GHz, 8GB RAM), application run smoothly. Here is my server T5440 info: ... (6 Replies)
Discussion started by: insatiable1610
6 Replies
AMTAPE(8)						      System Manager's Manual							 AMTAPE(8)

NAME
amtape - user interface to Amanda tape changer controls SYNOPSIS
amtape config command [ command options ] DESCRIPTION
Amtape performs tape changer control operations. It uses the underlying tape changer script defined by the tpchanger option for a particu- lar Amanda configuration as specified by the config argument. Tape changers maintain a notion of the current and next slot for each configuration. These may or may not correspond to an actual physical state of the device, but do tend to minimize searching through the tape storage slots. If the desired tape is in the current slot, it is likely the next tape needed is in the next slot rather than at some random position in the storage slots. See the amanda(8) man page for more details about Amanda. COMMANDS
reset Reset the tape changer to a known state. The current slot is set to the first slot. Other device-specific side effects may occur. Some gravity stackers need to be reset to the top position by hand. This command notifies Amanda the stacker is back in that posi- tion. eject If a tape is loaded in the drive, it is ejected and returned to the slot from which it was loaded. clean If a cleaning tape is defined for the changer, it is used to clean the drive. show Show the contents of all slots. This can be slow. label label Search for and load the Amanda tape with label label. taper Perform the taper scan algorithm. Load the next tape in the configuration's tape sequence, or a fresh tape with a suitable label. device Display the name of the current tape device on stdout. current Display the current slot. update Update the changer label database, if it has one, to match the tapes now available. slot slot Eject any tape in the drive and put it away, then load the tape from slot slot and reset current. slot current Eject any tape in the drive and put it away, then load the tape from the current slot. slot prev Eject any tape in the drive and put it away, then load the tape from the previous slot and reset current. slot next Eject any tape in the drive and put it away, then load the tape from the next slot and reset current. slot first Eject any tape in the drive and put it away, then load the tape from the first slot and reset current. slot last Eject any tape in the drive and put it away, then load the tape from the last slot and reset current. slot advance Eject any tape in the drive and put it away. Advance current to the next tape, but do not load it. This is useful with non-gravity stackers to unload the last tape used and set up Amanda for the next run. If you just use eject, the current tape will be mounted again in the next run, where it will be rejected as being still in use, ejected and the next tape requested. Using slot next followed by eject does an unnecessary mount. Note: most changers optimize the slot commands to not eject the loaded tape if it is the one being requested. AUTHOR
James da Silva <jds@cs.umd.edu> University of Maryland, College Park SEE ALSO
amanda(8) AMTAPE(8)
All times are GMT -4. The time now is 12:27 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy