10-08-2008
use release 05/08. update the firmware and set your output device to screen and input device to keyboard. set you diag level to min and diag switch to false, if not it will take long when you power up your system and you wont have any idea of whether the system is responding or not, unless you're using a serial connection
9 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
I was trying to test run a /bin/bash script i had just written when my monitor suddenly went blank.I had to shut down the machine from the systems main power. I was unable to boot afterwards and soo i went for the interactive boot process by typing boot -a.
I succeded in the first stage of the... (1 Reply)
Discussion started by: lealyz
1 Replies
2. Solaris
Hi,
I have a Sun 3500 server on which i installed solaris 8 and have also installed veritas 4.0 on it. i dont know why from the time i have built this server whenever i try to boot it, the server doesnot come back smooth.... i have got to connect a laptop to the serial port of the server and... (3 Replies)
Discussion started by: ishila
3 Replies
3. UNIX for Dummies Questions & Answers
Hello all,
I'm lost and can't figure this problem out.
I have a Sun fire 280R running Solaris 8. Everything was working great. I have one drive in bay 1(not 0). But when I reboot the system it trys to open files in /dev/rdsk/c1t1d0s0. Should it have been opeing /dev/rdsk/c1t0d0s0, the... (4 Replies)
Discussion started by: larryase
4 Replies
4. Solaris
Hi,
I have a sun ultra enterprise 450 server. This server powers on and a white screen appears with the system and network information.
But it doesnot boot up completely. Booting operation wil be halted by a warning:
\usr\sbin\fsck not found. Most likely the mount of \usr failed or the... (5 Replies)
Discussion started by: tgashwini
5 Replies
5. Solaris
I am new to Sun.
I brought Sun Fire 280R to practice UNIX. What are the requirements for the monitor/CRT? Will it burn out old non-Sun CRTs? Does it need LCD monitor?
Thanks. (3 Replies)
Discussion started by: bramptonmt
3 Replies
6. Solaris
First of all it's shut down 60 second after power on and write on console :
SC Alert: Correct SCC not replaced - shutting managed system down!
This is cured by moving out battery from ALOM card.
Now server start to loop during the testing.
That's on the console:
>@(#) Sun Fire V440,Netra... (14 Replies)
Discussion started by: Alisher
14 Replies
7. Solaris
Dear Team,
I need some expert advice to my problem.
We have a Sun Fire v440 in our customer Place. Server is working fine and no hardware deviations are found except one problem that processors generating too much heat. I have verified and found that the room temperature was 26-27 degree.... (5 Replies)
Discussion started by: sudhansu
5 Replies
8. Solaris
Booting problem on Sun 3500
Hi,
I have a Sun 3500 server on which i installed solaris 5.2 installed . i dont know why from the time i have built this server whenever i try to boot it, the server doesnot come back smooth.i got a message Sync file system than restart
some times showing ok... (2 Replies)
Discussion started by: najeer
2 Replies
9. Solaris
Hello,
I have purchaced an old SUn fire x2270 server .
I wanted to make ILOM upgrade to the latest version of software :
ILOM 3.0.9.18.a r126592
BIOS vers. 2.09
Server 2.2.3
(10-Aug-2018)
Because my version is very outdated.
But i can't download the updatebecause it's require... (4 Replies)
Discussion started by: LouisLakoute
4 Replies
LEARN ABOUT CENTOS
fence_ipmilan
FENCE_AGENT(8) System Manager's Manual FENCE_AGENT(8)
NAME
fence_ipmilan - Fence agent for IPMI over LAN
fence_ilo3 - Fence agent for HP iLO3 (symlink)
fence_ilo4 - Fence agent for HP iLO4 (symlink)
fence_idrac - Fence agent for Dell iDRAC (symlink)
fence_imm - Fence agent for IBM Integrated Management Module (symlink)
DESCRIPTION
fence_ipmilan is an I/O Fencing agent which can be used with machines controlled by IPMI. This agent calls support software using ipmitool
(http://ipmitool.sf.net/).
To use fence_ipmilan with HP iLO 3 or HP iLO 4 you have to enable lanplus option (lanplus / -P) and increase wait after operation to 4 sec-
onds (power_wait=4 / -T 4)
fence_ipmilan accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent.
fence_ipmilan can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts.
Vendor URL: http://www.intel.com
PARAMETERS
-A IPMI Lan Auth type (md5, password, or none)
-a IPMI Lan IP to talk to This parameter is always required.
-p Password (if required) to control power on IPMI device
-S Script to retrieve password (if required)
-P Use Lanplus to improve security of connection
-l Username/Login (if required) to control power on IPMI device
-o Operation to perform. Valid operations: on, off, reboot, status, list, diag, monitor or metadata (Default Value: reboot)
-t Timeout (sec) for IPMI operation
-C Ciphersuite to use (same as ipmitool -C parameter)
-M Method to fence (onoff or cycle) (Default Value: onoff)
-T Wait X seconds after on/off operation (Default Value: 2)
-f Wait X seconds before fencing is started
-L Privilege level on IPMI device
-v Verbose mode
ACTIONS
on Power on machine.
off Power off machine.
reboot Reboot machine.
status This returns the status of the plug/virtual machine.
diag
The operational behavior of this is not known.
list List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise.
monitor
Check the health of fence device
metadata
Display the XML metadata describing this resource.
STDIN PARAMETERS
auth IPMI Lan Auth type (md5, password, or none)
ipaddr IPMI Lan IP to talk to This parameter is always required.
passwd Password (if required) to control power on IPMI device
passwd_script
Script to retrieve password (if required)
lanplus
Use Lanplus to improve security of connection
login Username/Login (if required) to control power on IPMI device
action Operation to perform. Valid operations: on, off, reboot, status, list, diag, monitor or metadata (Default Value: reboot)
timeout
Timeout (sec) for IPMI operation
cipher Ciphersuite to use (same as ipmitool -C parameter)
method Method to fence (onoff or cycle) (Default Value: onoff)
power_wait
Wait X seconds after on/off operation (Default Value: 2)
delay Wait X seconds before fencing is started
privlvl
Privilege level on IPMI device
verbose
Verbose mode
fence_ipmilan (Fence Agent) 2009-10-20 FENCE_AGENT(8)