Sponsored Content
Operating Systems Solaris PLOGI failed state=Packet Transport error Post 302235557 by DukeNuke2 on Friday 12th of September 2008 07:01:42 AM
Old 09-12-2008
you have to give more information... what server, what kind of storage, san switch?
with only log files we are not able to help you...


possilbe reasons for the error:
- fc-cable is defect
- switch port is disabled
- lun security
- ....
 

10 More Discussions You Might Find Interesting

1. HP-UX

Error: XDMCP timed out. State=4 (CollectBroadcastQuery)

Hello, I am a new member of this forum. I am trying to solve a following problem with CDE in HPUX 11. The error is Error: XDMCP timed out. State=4 (CollectBroadcastQuery). I have uncommented the following lines from the Xaccess file - * grant service to all remote displays * ... (0 Replies)
Discussion started by: shad
0 Replies

2. Solaris

Unable to bring a disk from error to online state.

Hello experts. I am using Solaris 10(2005) on intel machine. I have installed Veritas Volume manager 5.0. I am unable to bring a disk error to online state. I would like to bring that disk to CDS format. Commands i used and output are.... #vxdisk list DEVICE TYPE ... (11 Replies)
Discussion started by: younus_syed
11 Replies

3. UNIX for Advanced & Expert Users

Transport Error

Dear Friends, I am using Solaris 10 on Sun Sparc T5120 with 4 HDD(Raid).I am getting transport error in one of my mirrored HDD c1t2d0. Below is a screen shot. I have replaced the HDD with new one but still the same. Any one can help???? c1t2d0 Soft Errors: 0 Hard Errors: 0... (1 Reply)
Discussion started by: solaris5.10
1 Replies

4. Solaris

Cygwin X Server error: xdmcp fatal error session failed session 23 failed for display

Hi, i got the following error when i tried to access the cygwin x server from a windows XP PC. "xdmcp fatal error session failed session 23 failed for display" Alternatively, when i tried to access the same Cygwin X Server from another windows XP PC which is on a different LAN... (3 Replies)
Discussion started by: HarishKumarM
3 Replies

5. UNIX for Advanced & Expert Users

sftp error:- Couldn't send packet: Broken pipe

Hi, I am trying to sftp a large file(appx. 2 GB size) from solaris 10 to a Linux server. While sftping(with no options), connection is terminated after some time with broken pipe error. sftp with option -R1 or -B1500 is successful. Linux server ssh Version: OpenSSH_3.9p1, OpenSSL 0.9.7a... (3 Replies)
Discussion started by: brij123
3 Replies

6. Solaris

RED State Exception error in V250

hi all i am getting following error while starting V250 server on console we are not able to go to OBP also. RED State Exception Error enable reg: 0000.0000.0000.0000 CPU 0000.0000.0000.0001 AFSR 0030.02ae.18c0.00b7 Multiple PRIV UCU CPU WDU EDU U E CE FRC FRU (2 Replies)
Discussion started by: nikhil kasar
2 Replies

7. AIX

Open firmware state to running state

Hi Admins, I am having a whole system lpar in open firmware state on HMC. How can I bring it to running state ? Let me know. Thanks. (2 Replies)
Discussion started by: snchaudhari2
2 Replies

8. AIX

Packet loss coming with big packet size ping

(5 Replies)
Discussion started by: Vishal_dba
5 Replies

9. Shell Programming and Scripting

Solaris ping report failed packet script

Hello, on Solaris ping command does not report failed packet as in i.e. Windows (Connection timeout) Instead it reports the sequence of the sent packet: 64 bytes from 10.80.4.120: icmp_seq=11. time=36.0 ms 64 bytes from 10.80.4.120: icmp_seq=12. time=35.9 ms 64 bytes from 10.80.4.120:... (6 Replies)
Discussion started by: drbiloukos
6 Replies

10. AIX

Error received when I was trying to check state of boot record

Hello, This is a test/lab LPAR. Recently installed and updated the SP/TL. everything seems to be working fine. (ran all post install checks) I checked the state of boot record, received the following error/failed message. Can you please explain what does this mean ? />ipl_varyon -i ... (1 Reply)
Discussion started by: dio34
1 Replies
scconf_transp_adap_hme(1M)				  System Administration Commands				scconf_transp_adap_hme(1M)

NAME
scconf_transp_adap_hme - configure the hme transport adapter DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. You can configure hme Ethernet adapters as cluster transport adapters. These adapters can only be used with transport type dlpi. The hme Ethernet adapter connects to a transport switch or to another Ethernet adapter on a different node. In either case, the connection is made through a transport cable. When a transport switch is used and the endpoints of the transport cable are configured using scconf, scinstall, or other tools, you are asked to specify a port name on the transport switch. You can provide any port name, or accept the default, as long as the name is unique for the switch. The default is to set the port name to the node ID hosting the adapter at the other end of the cable. There are no user configurable properties for cluster transport adapters of this type. SEE ALSO
Intro(1CL), clinterconnect(1CL), clnode(1CL), scconf(1M), scinstall(1M), hme(7D) Sun Cluster 3.2 18 Jul 2006 scconf_transp_adap_hme(1M)
All times are GMT -4. The time now is 09:00 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy