Sponsored Content
Full Discussion: Aix raid ?
Operating Systems AIX Aix raid ? Post 302231385 by art on Tuesday 2nd of September 2008 07:40:55 AM
Old 09-02-2008
Quote:
Originally Posted by shockneck
As long as you maintain a correctly mirrored rootvg an AIX server will not run into deep trouble when one disk fails. That a server becomes "extremely busy" after a disk went missing sounds like the server was trying to find information that was not on the remaining disk.
So for reasons of safe operation there is rarely a need for a physical raid adapter. If you are new to AIX and unsure about how to use mirroring, you might use the mirrorvg command to mirror your rootvg. This has the advantage over mklvcopy that one cannot forget to mirror the boot device hd5 or the paging space.
When you add an LV later make sure that you tell LVM to create 2 copies (default is just 1 - even if the VG is mirrored already, leaving you with a partly mirrored VG) and place each copy on a separate disk. This way you will hardly run into dire straits when a disk goes missing.
I'm not talking about a minute or more of extreme business, just enough that the software running on the server felt starved of resources and decided to exit.... And yes I'm sure that the mirror was correctly set up.

But it's kind of a mute point since I've heard what a dedicated hardware raid on p-series server costs.... approx. $3000.... which is kinda LOT Smilie Smilie
 

9 More Discussions You Might Find Interesting

1. AIX

Creating RAID 5 for AIX 5.2

Hi guys!! I terribly need help in setting up RAID 5 for a P615 IBM server. IBM said that I needed a diagnostic cd but it will take them 6 weeks to send it to me. I need help PLEASE Server configuration: P615 IBM Server 3 pcs 36.4GB HDD Dual Channel SCSI RAID Enab. Card Thank you, Jose (0 Replies)
Discussion started by: josramon
0 Replies

2. AIX

how to identify the raid type on aix

hi how to identify the raid type on aix? thx (1 Reply)
Discussion started by: melanie_pfefer
1 Replies

3. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

4. Solaris

implementing RAID 1 from RAID 5

Dear ALl, I have a RAID 5 volume which is as below d120 r 60GB c1t2d0s5 c1t3d0s5 c1t4d0s5 c1t5d0s5 d7 r 99GB c1t2d0s0 c1t3d0s0 c1t4d0s0 c1t5d0s0 d110 r 99GB c1t2d0s4 c1t3d0s4 c1t4d0s4 c1t5d0s4 d8 r 99GB c1t2d0s1 c1t3d0s1... (2 Replies)
Discussion started by: jegaraman
2 Replies

5. Solaris

Creation of Raid 01 and Raid 10

Hello All, I have read enough of texts on Raid 01 and Raid 10 on solaris :wall: . But no-where found a way to create them using SVM. Some one pls tell me how to do or Post some link if that helps. TIA Curious solarister (1 Reply)
Discussion started by: Solarister
1 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

8. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies

9. AIX

SAN DISK raid level in AIX

Hello All, Our servers having emc clarion for the data disks. Is that possible to see those san disks raid level from AIX ? Am having AIX 6.1 and EMC clarion 5.5. Regards, Gowtham.G (3 Replies)
Discussion started by: gowthamakanthan
3 Replies
MKINITRD(8)						      System Manager's Manual						       MKINITRD(8)

NAME
mkinitrd - creates initial ramdisk images for preloading modules SYNOPSIS
mkinitrd [--version] [-v] [-f] [--preload=module] [--omit-scsi-modules] [--omit-raid-modules] [--omit-lvm-modules] [--with=module] [--image-version] [--fstab=fstab] [--nocompress] [--builtin=module] [--nopivot] image kernel-version DESCRIPTION
mkinitrd creates filesystem images which are suitable for use as Linux initial ramdisk (initrd) images. Such images are often used for preloading the block device modules (such as IDE, SCSI or RAID) which are needed to access the root filesystem. mkinitrd automatically loads filesystem modules (such as ext3 and jbd), IDE modules, all scsi_hostadapter entries in /etc/modules.conf, and raid modules if the system's root partition is on raid, which makes it simple to build and use kernels using modular device drivers. Any module options specified in /etc/modules.conf are passed to the modules as they are loaded by the initial ramdisk. If the root device is on a loop device (such as /dev/loop0), mkinitrd will build an initrd which sets up the loopback file properly. To do this, the fstab must contain a comment of the form: # LOOP0: /dev/hda1 vfat /linux/rootfs LOOP0 must be the name of the loop device which needs to be configured, in all capital lettes. The parameters after the colon are the device which contains the filesystem with the loopback image on it, the filesystem which is on the device, and the full path to the loop- back image. If the filesystem is modular, initrd will automatically add the filesystem's modules to the initrd image. The root filesystem used by the kernel is specified in the boot configuration file, as always. The traditional root=/dev/hda1 style device specification is allowed. If a label is used, as in root=LABEL=rootPart the initrd will search all available devices for an ext2 or ext3 filesystem with the appropriate label, and mount that device as the root filesystem. OPTIONS
--builtin=module Act as if module is built into the kernel being used. mkinitrd will not look for this module, and will not emit an error if it does not exist. This option may be used multiple times. -f Allows mkinitrd to overwrite an existing image file. --fstab=fstab Use fstab to automatically determine what type of filesystem the root device is on. Normally, /etc/fstab is used. --image-version The kernel version number is appended to the initrd image path before the image is created. --nocompress Normally the created initrd image is compressed with gzip. If this option is specified, the compression is skipped. --nopivot Do not use the pivot_root system call as part of the initrd. This lets mkinitrd build proper images for Linux 2.2 kernels at the expense of some features. In particular, some filesystems (such as ext3) will not work properly and filesystem options will not be used to mount root. This option is not recommended, and will be removed in future versions. --omit-lvm-modules Do not load any lvm modules, even if /etc/fstab expects them. --omit-raid-modules Do not load any raid modules, even if /etc/fstab and /etc/raidtab expect them. --omit-scsi-modules Do not load any scsi modules, including 'scsi_mod' and 'sd_mod' modules, even if they are present. --preload=module Load the module module in the initial ramdisk image. The module gets loaded before any SCSI modules which are specified in /etc/mod- ules.conf. This option may be used as many times as necessary. -v Prints out verbose information while creating the image (normally the mkinitrd runs silently). --version Prints the version of mkinitrd that's being used and then exits. --with=module Load the modules module in the initial ramdisk image. The module gets loaded after any SCSI modules which are specified in /etc/mod- ules.conf. This option may be used as many times as necessary. FILES
/dev/loop* A block loopback device is used to create the image, which makes this script useless on systems without block loopback support available. /etc/modules.conf Specified SCSI modules to be loaded and module options to be used. SEE ALSO
fstab(5), insmod(1), kerneld(8), lilo(8) AUTHOR
Erik Troan <ewt@redhat.com> 4th Berkeley Distribution Sat Mar 27 1999 MKINITRD(8)
All times are GMT -4. The time now is 01:34 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy