you can go for ipcs(interprocess communication facility status) with following option-q to clear queue-m to clear messages-s to clear semaphore
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

How do I get the unused space?

One of my Solaris 8 machines hd was about to die. So I used g4u to create an image of the 9gb drive and I put it in a 36gb drive. That solved my dieing hd problem. But.... How do I get my machine to see the unused 27gb of space? Any help would be greatly appreciated. (1 Reply)
Discussion started by: Spyzic
1 Replies

2. AIX

unused storage on AIX 4.3

Hi, How do I query for unused partition in AIX 4.3 with DAS and SAA storage? I know most unix administrator don't put all the capacity on the system at once. thanks, vene (1 Reply)
Discussion started by: venerayan
1 Replies

3. UNIX for Dummies Questions & Answers

delete the unused file

Hi All, Can you please let me know how to delete any files that have not been accessed in the past 28 days in a directory. Thanks, Arun (3 Replies)
Discussion started by: arunkumar_mca
3 Replies

4. HP-UX

HP-UX using unused HDD space

Hello, I have a system with HP-UX 11.23 installed on it. There are ~36GB of unused space on the HDD. I did a very basic installation, and it created the usual volume group /dev/vg00. When I look at the output of ioscan -funC disk, I see this (and more, but irrelevant to this post): disk ... (1 Reply)
Discussion started by: goon12
1 Replies

5. Solaris

unused disk space

i Have alloted 20G in my vmware for solaris 10, upon installation, and some distribution of disk space to /,/opt,swap i just use 19G. Can i still use the 1G? How? how to see the 1G? that i did not use? how can i use it? appreciate your responce (17 Replies)
Discussion started by: kenshinhimura
17 Replies

6. AIX

Temporarily disabling unused ethernet adapter

Hi, In our AIX 5.2 server , we have one unused ethernet adapter which doesn't have cable connection . For this interface , we are getting alerts in errpt . Could you suggesthow to stop this alert ? And sametime i would like to keep this device in ODM . Is there... (1 Reply)
Discussion started by: sekarsamy
1 Replies

7. AIX

locking down unused or unwanted ports in AIX

We have a system and we have modified the /etc/ind.conf and the /etc/services and the /etc/rc.tcpip file to turn off specific applications. I need to know what is the correct procedure for locking down unused ports that still appear to be in a listen mode even... (1 Reply)
Discussion started by: admaix
1 Replies

8. Programming

What Unix do with unused shared memory?

Hello, When creating shared memory in C, should be remove shared memory with shmctl function when don't need it. If it didn't remove, occupied shared memory stay and remain. If we create shared memory repeatedly without removing unusable shared memory, /dev/shm will full. Does Unix or... (1 Reply)
Discussion started by: pronetin
1 Replies

9. UNIX for Advanced & Expert Users

Detecting unused variables...

Hi guys... The first active code line in AudioScope.sh is set -u . This causes a complete exit if a variable is used/found but has not been allocated at the start of the program. However, apart from writing code to do the task, is there a switch to to check which variables have been... (17 Replies)
Discussion started by: wisecracker
17 Replies
ipcs(1) 							   User Commands							   ipcs(1)

NAME
ipcs - report inter-process communication facilities status SYNOPSIS
ipcs [-aAbciJmopqstZ] [-D mtype] [-z zone] DESCRIPTION
The ipcs utility prints information about active inter-process communication facilities. The information that is displayed is controlled by the options supplied. Without options, information is printed in short format for message queues, shared memory, and semaphores that are currently active in the system. OPTIONS
The following options are supported: -m Prints information about active shared memory segments. -q Prints information about active message queues. -s Prints information about active semaphores. If -m, -q, or -s are specified, information about only those indicated is printed. If none of these three is specified, information about all three is printed subject to these options: -a Uses all XCU5 print options. (This is a shorthand notation for -b, -c, -o, -p, and -t.) -A Uses all print options. (This is a shorthand notation for -b, -c, -i, -J, -o, -p, and -t.) -b Prints information on biggest allowable size: maximum number of bytes in messages on queue for message queues, size of seg- ments for shared memory, and number of semaphores in each set for semaphores. See below for meaning of columns in a list- ing. -c Prints creator's login name and group name. See below. -D mtype Displays, in hexadecimal and ASCII, the contents of all messages of type mtype found on any message queue that the user invoking ipcs has permission to read. If mtype is 0, all messages are displayed. If mtype is negative, all messages with type less than or equal to the absolute value of mtype are displayed. (See msgrcv(2) and msgsnap(2)). -i Prints number of ISM attaches to shared memory segments. -J Prints the creator's project. -o Prints information on outstanding usage: number of messages on queue and total number of bytes in messages on queue for message queues and number of processes attached to shared memory segments. -p Prints process number information: process ID of last process to send a message, process ID of last process to receive a message on message queues, process ID of creating process, and process ID of last process to attach or detach on shared memory segments. See below. -t Prints time information: time of the last control operation that changed the access permissions for all facilities, time of last msgsnd(2) and last msgrcv(2) on message queues, time of last shmat(2) and last shmdt(2 ) on shared memory (see shmop(2)), time of last semop(2) on semaphores. See below. -z zone Prints information about facilities associated with the specified zone (see zones(5)). The zone can be specified as either a name or a numeric id. The default is to display information about the zone in which the command is executing. Notice that this option is only useful when executing in the global zone. -Z When executing in the global zone, prints information about all zones. Otherwise, prints information about the zone in which the command is executing. The output includes the zone associated with each facility. The column headings and the meaning of the columns in an ipcs listing are given below. The letters in parentheses indicate the options that cause the corresponding heading to appear and "all" means that the heading always appears. Note: These options only determine what informa- tion is provided for each facility; they do not determine which facilities are listed. T (all) Type of the facility: q message queue m shared memory segment s semaphore ID (all) The identifier for the facility entry. KEY (all) The key used as an argument to msgget(2), semget(2), or shmget(2) to create the facility entry. (Note: The key of a shared memory segment is changed to IPC_PRIVATE when the segment has been removed until all processes attached to the segment detach it.) MODE (all) The facility access modes and flags: The mode consists of 11 characters that are interpreted as follows. The first two characters are: R A process is waiting on a msgrcv(2). S A process is waiting on a msgsnd(2). D The associated shared memory segment has been removed. It will disappear when the last process attached to the segment detaches it. (Note: If the shared memory segment identifier is removed via an IPC_RMID call to shmctl(2) before the process has detached from the segment with shmdt(2), the segment is no longer visible to ipcs and it will not appear in the ipcs output.) C The associated shared memory segment is to be cleared when the first attach is executed. - The corresponding special flag is not set. The next nine characters are interpreted as three sets of three bits each. The first set refers to the owner's per- missions; the next to permissions of others in the user-group of the facility entry; and the last to all others. Within each set, the first character indicates permission to read, the second character indicates permission to write or alter the facility entry, and the last character is currently unused. The permissions are indicated as follows: r Read permission is granted. w Write permission is granted. a Alter permission is granted. - The indicated permission is not granted. OWNER (all) The login name of the owner of the facility entry. GROUP (all) The group name of the group of the owner of the facility entry. CREATOR (a,A,c) The login name of the creator of the facility entry. CGROUP (a,A,c) The group name of the group of the creator of the facility entry. CBYTES (a,A,o) The number of bytes in messages currently outstanding on the associated message queue. QNUM (a,A,o) The number of messages currently outstanding on the associated message queue. QBYTES (a,A,b) The maximum number of bytes allowed in messages outstanding on the associated message queue. LSPID (a,A,p) The process ID of the last process to send a message to the associated queue. LRPID (a,A,p) The process ID of the last process to receive a message from the associated queue. STIME (a,A,t) The time the last message was sent to the associated queue. RTIME (a,A,t) The time the last message was received from the associated queue. CTIME (a,A,t) The time when the associated entry was created or changed. ISMATTCH (a,i) The number of ISM attaches to the associated shared memory segments. NATTCH (a,A,o) The number of processes attached to the associated shared memory segment. SEGSZ (a,A,b) The size of the associated shared memory segment. CPID (a,A,p) The process ID of the creator of the shared memory entry. LPID (a,A,p) The process ID of the last process to attach or detach the shared memory segment. ATIME (a,A,t) The time the last attach was completed to the associated shared memory segment. DTIME (a,A,t) The time the last detach was completed on the associated shared memory segment. NSEMS (a,A,b) The number of semaphores in the set associated with the semaphore entry. OTIME (a,A,t) The time the last semaphore operation was completed on the set associated with the semaphore entry. PROJECT (J,A) The project name of the creator of the facility entry. ZONE (Z) The zone with which the facility is associated. ENVIRONMENT VARIABLES
See environ(5) for descriptions of the following environment variables that affect the execution of ipcs: LANG, LC_ALL, LC_CTYPE, LC_MES- SAGES, and NLSPATH. TZ Determine the timezone for the time strings written by ipcs. FILES
/etc/group group names /etc/passwd user names ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWipc | +-----------------------------+-----------------------------+ |Interface Stability |Standard | +-----------------------------+-----------------------------+ SEE ALSO