07-27-2008
is probably a new disk, and not yet have a disk label.
try format.
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
I have been asked to look at an AIX box that the owner (not a technical person) installed a new SCSI disk into, but cannot figure out how to build volumes or file systems on. It has been years since I messed with AIX, and I remember enough to know that it isn't like Solaris.
To make things... (1 Reply)
Discussion started by: 98_1LE
1 Replies
2. Filesystems, Disks and Memory
Hi all,
I am using SCO Openserver V and I want to add one more harddisk (/dev/hd1) Hw can I do it? (1 Reply)
Discussion started by: skant
1 Replies
3. Filesystems, Disks and Memory
I enquired before about adding another disk to an ultra 10...
and was told it was possible...
Well - since then I got my hands on another ultra 10 - and have taken the disk out of that one...
I should be able to connect it up - but I am wondering - should this be mounted in any partiulcar... (2 Replies)
Discussion started by: frustrated1
2 Replies
4. Solaris
Dear all ,
I am new to sun cluster and i having a problem adding a disk to a disk group .
My platfrom consists of a clustered E6900 SUN server and an EMC DX1000 storage .
the disk group that iam trying to add the disk to is shared group ,
whwen i run vxdisk list i get in status "online... (2 Replies)
Discussion started by: ppass
2 Replies
5. HP-UX
Hi dear(s)
Can u explain how to add a disk through lvm with commands.
I need to add a 9 gb scsi HS disk to a Hp D class 9000 server. (2 Replies)
Discussion started by: sreekumar.R
2 Replies
6. Solaris
Hi experts,
i have added a new disk to my ultra 10 system, after that i am unable to boot the system, its not booting from disk neither from cd.
please help!
Regards (16 Replies)
Discussion started by: kumarmani
16 Replies
7. Filesystems, Disks and Memory
Recently added a disk to a clariion array system, binded it as a raid 5, now I have no clue how to see it in dg-unix. I want to add it to a current filesystem, and now i'm down river without a paddle. (0 Replies)
Discussion started by: danceofillusion
0 Replies
8. Solaris
We have hardware RAID configured on Sun-Blade-T6320 and one of the disk got failed. Hence we replaced the failed disk. But the hot swapped disk not recognized by RAID. Kindly help on fixing this issue.
We have 2 LDOM configured on this server and this server running on single disk.
#... (8 Replies)
Discussion started by: rock123
8 Replies
9. AIX
Hi,
On P5 I would like to add hard drive, currently 2 hard disk are already exists, would like to add one more,
2 Slots are emtpy, I would like to know how to find out wheather adapter is attached to that 2 free slot using command. (7 Replies)
Discussion started by: manoj.solaris
7 Replies
10. AIX
hi all i have entered Aix environment 4 months had experienced in linux
what i am facing is i am unable to do sort of RnD with aix like
installation on my own, creating vgs managing networks, the VIOS, storage,lpars,
So we have a setup here almost all are in live production environment
with... (4 Replies)
Discussion started by: vax
4 Replies
LEARN ABOUT OSF1
volreattach
volreattach(8) System Manager's Manual volreattach(8)
NAME
volreattach - Reattaches disk drives that have once again become accessible
SYNOPSIS
/usr/sbin/volreattach [-rb] [accessname...]
/usr/sbin/volreattach -c accessname
OPTIONS
The volreattach utility has the following options: Calls the volrecover utility to attempt to recover stale plexes of any volumes on the
failed disk. Performs the reattach operation in the background. Checks whether a reattach is possible. No operation is performed, but the
name of the disk group and disk media name at which the disk can be reattached is displayed.
DESCRIPTION
The volreattach utility attempts to reattach disks using the same disk group and media names they had before detachment.
This operation may be necessary if a disk has a transient failure, or if some disk drivers are unloaded or unloadable when the Logical
Storage Manager is started, causing disks to enter the failed state.
If the problem is fixed, the volreattach command can be used to reattach the disks without plexes being flagged as stale, as long as the
reattach happens before any volumes on the disk are started.
The volreattach command is called from the voldiskadm menus as part of disk recovery.
The volreattach utility tries to find a disk with a disk group and disk ID matching that of the disk(s) being reattached. If the matching
disk is found, the reattach operation may still fail if the original cause (or some other cause) for the disk failure still exists.
EXIT CODES
A zero exit status is returned if it is possible to perform a reattach. Otherwise, non-zero is returned.
SEE ALSO
volintro(8), voldiskadm(8), volrecover(8)
volreattach(8)