post some more information about your system....

df -h
format | echo
vxprint -ht
 

8 More Discussions You Might Find Interesting

1. IP Networking

unable to bring up any interface

I have Linux 7.1 setup on a Dell and am unable to bring up any interfaces. Both the lo and eth0 fail upon boot up and I get a insmod error possibly due to bad irq or IO setting. If I disable eth0 upon boot, then lo works fine, but offcourse I get the "delaying initialization" upon boot for eth0... (1 Reply)
Discussion started by: alam
1 Replies

2. UNIX for Dummies Questions & Answers

Unable to bring up Sun OS

The last thing I did was set REMOTE_LOGIN_PASSWORDFILE to EXCLUSIVE. Then rebooted server. Since that time I have not been able to login. During bootup it can't find root and generates alot of errors. Does anybody know of a default login and password that will allow me to log in and rebuild the... (2 Replies)
Discussion started by: mayewil
2 Replies

3. Red Hat

Information About Solid State Disk in Linux

Hello, I have few HDD and SSD installed in my RHEL 5 server. I want to know which disk are SDD and which are HDD. What command should I use? Thanks (3 Replies)
Discussion started by: fahdmirza
3 Replies

4. Linux

Please Guide to bring my Server online

Hi Guys, I want to bring my server live. I have Static public IP Address 123.99.88.77 (Say) and also I have also registered a domain name say(live server23.com) the domain name providers have also given me the control panel with DNS management settings. I have gateway 192.168.1.1 Now My... (1 Reply)
Discussion started by: manalisharmabe
1 Replies

5. Solaris

DNS service is in maintenance mode. How to bring it back to online mode?

:confused: when i tried to look the status of DNS-client, it is in maintenance mode..... Please tell me how to bring it back to online mode...PLEASE TELL ME STEP BY STEP.... PLEASE... :wall: (2 Replies)
Discussion started by: vamshigvk475
2 Replies

6. Solaris

Unable to bring iscsitgt service to online

this is samiulla in my vmware solaris 11 i installed iscsitgt pakage but it goes to maintenance and i am unable to bring into online with svcadm clear iscsitgt how can i forcefully online iscsitgt service. (1 Reply)
Discussion started by: samiulla
1 Replies

7. Shell Programming and Scripting

Unable to catch the redirection error when the disk is full

Hi Experts, Problem summary : I am facing the below problem on huge files when the disk is getting full on the half way through the execution. If the disk was already full , the commands fail & everything is fine. Sample Code : head_rec_data_file=`head -1 sample_file.txt` cat... (9 Replies)
Discussion started by: Pruthviraj_shiv
9 Replies

8. AIX

Power HA 6.1 Bring Resource group online issue

Hi all, I have the following in hacmp.out for bringing Resource group online. Volume groups themselves are Enhanced-Capable and on each node I can varyon and mount filesystems. +main1_rg_01:cl_activate_vgs STATUS=0 +main1_rg_01:cl_activate_vgs typeset -li STATUS +main1_rg_01:cl_activate_vgs... (2 Replies)
Discussion started by: OdilPVC
2 Replies
pfto(7) 						 Miscellaneous Information Manual						   pfto(7)

NAME
pfto - Powerfail Timeout DESCRIPTION
HP-UX SCSI disk device drivers have a timeout facility that detects non-responding disks. VxVM uses this mechanism in its Powerfail Time- out (pfto) feature. You can specify a timeout value for individual VxVM disks using the vxdisk command (see the EXAMPLES section below). If a disk fails to respond in the specified timeout period, the driver receives a timer interrupt. pfto values are persistent across reboots, that is, after the pfto value is set, it remains in effect until you explicitly change it. If dynamic multipathing is enabled, the pfto value set on a disk applies to each path of a multipath disk device. The pfto value is in seconds. If pfto is not specified, or is zero, the timeout period is 30 seconds. Both the vxdisk and vxprint commands display the current pfto value for a disk. EXAMPLES
Use the following command to set the value of pfto to 30 seconds on disk01: vxdisk -g rootdg set disk01 pfto=30 Use either of the following commands to display the pfto value on the VxVM disk disk01: vxdisk list disk01 vxprint -l disk01 EXIT CODES
Setting the pfto value on a non-VxVM disk returns an error. SEE ALSO