Sponsored Content
Operating Systems SCO driver needed for hp smartarry p200i sas raid controller Post 302211797 by jactroo on Friday 4th of July 2008 11:17:55 AM
Old 07-04-2008
I think that version of SCO doesn't support dvd units, it's great that the drivers help you.
 

10 More Discussions You Might Find Interesting

1. SCO

ultra 320 scsi raid controller driver for sco 5.0.6

I am facing a problem to install sco 5.0.6 in Dell Power Edge SC1420 which raid controller is ultra 320 scsi raid controller . how/from where to download the ultra 320 scsi raid controller driver for sco 5.0.6. Plz help with any idea karzon (1 Reply)
Discussion started by: karzon
1 Replies

2. Red Hat

sata/sas controller on redhat

Hi All, How do I verify the sata/sas controller status on my redhat 2.6? Thanks. Itik (1 Reply)
Discussion started by: itik
1 Replies

3. Solaris

RAID controller needed for SVM?

hi this may be a very stupid question, but im quite new to Solaris (gonna buid my first system, Solaris 10 on x86 system, connected to other windows systems in a home network) i wanna put a RAID 5 system in there to back up my other systems at home; iv read that its really so easy with SVM to... (4 Replies)
Discussion started by: Landser
4 Replies

4. Solaris

istall sas raid HBA internal card

I need to install a raid HBA internal card on a T5240. The reason is I have more drives and the current mother board controller does not support more than 4 drives. My question is I have raidctl set up on current drives. If I install new HBA card do I have to delete current raidctl and... (3 Replies)
Discussion started by: photon
3 Replies

5. Solaris

T5240 and Internal SAS RAID Configuration help

Dear Friends, I need to configure T5240 with Internal SAS RAID HBA(SG-XPCIESAS-R-INT-Z).. T5240 uses 8 hard disks... From the documents of RAID card I have found that I need to create a jump start server to include three packages SUNWaac, StorMan, SUNWgccruntime if Im using solaris10 5/08... ... (5 Replies)
Discussion started by: nicktrix
5 Replies

6. Hardware

Problem with External Raid Controller.

Hi, We have a Sunfire 4150 with On-Board Internal Raid Controller connected to 4 X 146 GB SAS disks. This also has an External Raid Controller (Storagetek Eight-Port, External HBA Model SG-XPCIESAS-R-EXT-Z) connected to a JBOD array ( Storagetek XTA2530 ) which has 5 X 300 GB Hard disk. ... (1 Reply)
Discussion started by: ranjansukumar
1 Replies

7. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

8. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies

9. SCO

How to change raid controller driver ? (hardware change)

Hello I'm trying to virtualize an instance of Sco Unix 5.0.5 in VirtualBox (called VM-A) , but sco I have problems set to launch with the new raid controller . The physical machine has a raid controller adaptec (alad driver) but VirtualBox uses buslogic (blc driver) What ... (3 Replies)
Discussion started by: flako
3 Replies

10. SCO

SCO OS 6 Driver for LSIL SAS1064E Raid Controller

Hi all, A client has an SCO OpenServer Server 6.0, that is running on an HP ProLiant Box and they lost the root password. Its equipped with a Doal-Core Intel Pentium Processor. They don't have any media or emergency disk anymore. I tried to boot with the CD Rom, then "Tools", then exit to... (7 Replies)
Discussion started by: thm2222
7 Replies
raidtab(5)							File Formats Manual							raidtab(5)

NAME
raidtab - configuration file for md (RAID) devices DESCRIPTION
/etc/raidtab is the default configuration file for the raid tools (raidstart and company). It defines how RAID devices are configured on a system. FORMAT
/etc/raidtab has multiple sections, one for each md device which is being configured. Each section begins with the raiddev keyword. The order of items in the file is important. Later raiddev entries can use earlier ones (which allows RAID-10, for example), and the parsing code isn't overly bright, so be sure to follow the ordering in this man page for best results. Here's a sample md configuration file: # # sample raiddev configuration file # 'old' RAID0 array created with mdtools. # raiddev /dev/md0 raid-level 0 nr-raid-disks 2 persistent-superblock 0 chunk-size 8 device /dev/hda1 raid-disk 0 device /dev/hdb1 raid-disk 1 raiddev /dev/md1 raid-level 5 nr-raid-disks 3 nr-spare-disks 1 persistent-superblock 1 parity-algorithm left-symmetric device /dev/sda1 raid-disk 0 device /dev/sdb1 raid-disk 1 device /dev/sdc1 raid-disk 2 device /dev/sdd1 spare-disk 0 Here is more information on the directives which are in raid configuration files; the options are listen in this file in the same order they should appear in the actual configuration file. raiddev device This introduces the configuration section for the stated device. nr-raid-disks count Number of raid devices in the array; there should be count raid-disk entries later in the file. (current maximum limit for RAID devices -including spares- is 12 disks. This limit is already extended to 256 disks in experimental patches.) nr-spare-disks count Number of spare devices in the array; there should be count spare-disk entries later in the file. Spare disks may only be used with RAID4 and RAID5, and allow the kernel to automatically build new RAID disks as needed. It is also possible to add/remove spares run- time via raidhotadd/raidhotremove, care has to be taken that the /etc/raidtab configuration exactly follows the actual configuration of the array. (raidhotadd/raidhotremove does not change the configuration file) persistent-superblock 0/1 newly created RAID arrays should use a persistent superblock. A persistent superblock is a small disk area allocated at the end of each RAID device, this helps the kernel to safely detect RAID devices even if disks have been moved between SCSI controllers. It can be used for RAID0/LINEAR arrays too, to protect against accidental disk mixups. (the kernel will either correctly reorder disks, or will refuse to start up an array if something has happened to any member disk. Of course for the 'fail-safe' RAID variants (RAID1/RAID5) spares are activated if any disk fails.) Every member disk/partition/device has a superblock, which carries all information necessary to start up the whole array. (for autodetection to work all the 'member' RAID partitions should be marked type 0xfd via fdisk) The superblock is not visible in the final RAID array and cannot be destroyed accidentally through usage of the md device files, all RAID data content is available for filesystem use. parity-algorithm which The parity-algorithm to use with RAID5. It must be one of left-asymmetric, right-asymmetric, left-symmetric, or right-symmetric. left-symmetric is the one that offers maximum performance on typical disks with rotating platters. chunk-size size Sets the stripe size to size kilobytes. Has to be a power of 2 and has a compilation-time maximum of 4M. (MAX_CHUNK_SIZE in the ker- nel driver) typical values are anything from 4k to 128k, the best value should be determined by experimenting on a given array, alot depends on the SCSI and disk configuration. device devpath Adds the device devpath to the list of devices which comprise the raid system. Note that this command must be followed by one of raid-disk, spare-disk, or parity-disk. Also note that it's possible to recursively define RAID arrays, ie. to set up a RAID5 array of RAID5 arrays. (thus achieving two-disk failure protection, at the price of more disk space spent on RAID5 checksum blocks) raid-disk index The most recently defined device is inserted at position index in the raid array. spare-disk index The most recently defined device is inserted at position index in the spare disk array. parity-disk index The most recently defined device is moved to the end of the raid array, which forces it to be used for parity. failed-disk index The most recently defined device is inserted at position index in the raid array as a failed device. This allows you to create raid 1/4/5 devices in degraded mode - useful for installation. Don't use the smallest device in an array for this, put this after the raid-disk definitions! NOTES
The raidtools are derived from the md-tools and raidtools packages, which were originally written by Marc Zyngier, Miguel de Icaza, Gadi Oxman, Bradley Ward Allen, and Ingo Molnar. SEE ALSO
raidstart(8), raid0run(8), mkraid(8), raidstop(8) raidtab(5)
All times are GMT -4. The time now is 06:49 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy