06-24-2008
failover on 4.5 hacmp
Hi All,
How do I trigger the failover on the second hacmp server?
Please give me idea and I will do the rest.
Thanks,
itik
10 More Discussions You Might Find Interesting
1. Solaris
Would anyone know why a V440 Solaris 9 machine's interfaces (ce0 and ce1)
will not failover?
Both interfaces are on the same subnet, but different IPs. I can pull the plug on once interface (ce0) and ce1 will be accessible. I can reverse it and pull ce1, and ce0 will NOT be accessible. ... (5 Replies)
Discussion started by: StorageGuy
5 Replies
2. AIX
Hello All,
Here is a snipet from our cluster.log, I was wondering if anyone could shed some light on what may have caused the failover.
The first two lines indicate a possible memory issue which I am currently looking into.
Thanks. (0 Replies)
Discussion started by: Wez
0 Replies
3. UNIX for Advanced & Expert Users
Hi,
I have 3 directories (/1 /2 and /3) with same contents and want to achieve fail over among them.
The Solution i thought of:
1. link /data to /1 (and provide users with /data to access)
2. CRON a script (to run every minute) to verify if /1 exist or not, if it does not exist (or its... (3 Replies)
Discussion started by: prvnrk
3 Replies
4. AIX
Hi All,
How do I failover on the ip load balancer (back and forth)? It involves first to load a new config on the passive ip. If success, load the new config on the ip active (which is now passive).
Any idea, please.
Thanks in advance. (0 Replies)
Discussion started by: itik
0 Replies
5. Solaris
The active NIC has been failing back and forth on two of our T2000s. I don't know when the problem originally began, but I can see failovers in the messages.* files. The network guy says the switches are clean (no errors) so I'm left looking at the configuration or any other issue that may be... (5 Replies)
Discussion started by: dangral
5 Replies
6. Solaris
Hi guys,
I'm running vxdmp and powerpath at the same time. Vxdmp for internal disks and powerpath for external.
The problem is that, on the failover tests which a fiber cable should be removed, the system cannot recognize the disks.
Any hints on how to configure powerpath in order to... (4 Replies)
Discussion started by: glenioborges
4 Replies
7. IP Networking
All,
I am looking to setup a simple IP failover setup, but it seems every place i look has some difficult setup like pacemaker or LVS.
I only want to handle the IP piece to failover a VIP.
Any suggestions? I checked out keepalived and that my work for me. (4 Replies)
Discussion started by: markdjones82
4 Replies
8. Gentoo
How to failover the cluster ? GNU/Linux
By which command,
My Linux version
2008 x86_64 x86_64 x86_64 GNU/Linux
What are the prerequisites we need to take while failover ?
if any
Regards (3 Replies)
Discussion started by: sidharthmellam
3 Replies
9. AIX
hi,
when I do a failover, hacmp always starts db2 but recently it fails to start db2..noticed the issue is db2nodes.cfg is not modified by hacmp and is still showing primary node..manually changed the node name to secondary after which db2 started immediately..unable to figure out why hacmp is... (4 Replies)
Discussion started by: gkr747
4 Replies
10. AIX
Would anyone please kindly help to solve this problem...
An LPAR with the below network configuration. ent0 and ent1 are logical lan (virtual ethernet) from VIO SEA.
en0
1.2.3.4 <- boot ip
192.168.1.1 <- persistent ip
192.168.1.10 <- service ip
en1
11.22.33.44 <- boot ip
When I... (6 Replies)
Discussion started by: skeyeung
6 Replies
LEARN ABOUT LINUX
if_mpadm
if_mpadm(1M) System Administration Commands if_mpadm(1M)
NAME
if_mpadm - change operational status of interfaces within a multipathing group
SYNOPSIS
/usr/sbin/if_mpadm -d interface_name
/usr/sbin/if_mpadm -r interface_name
DESCRIPTION
Use the if_mpadm utility to change the operational status of interfaces that are part of an IP multipathing group. If the interface is
operational, you can use if_mpadm -d to detach or off-line the interface. If the interface is off-lined, use if_mpadm -r to revert it to
its original state.
When a network interface is off-lined, all network access fails over to a different interface in the IP multipathing group. Any addresses
that do not failover are brought down. Network access includes unicast, broadcast, and multicast for IPv4 and unicast and multicast for
IPv6. Addresses marked with IFF_NOFAILOVER do not failover. They are marked down. After an interface is off-lined, the system will not use
the interface for any outbound or inbound traffic, and the interface can be safely removed from the system without any loss of network
access.
The if_mpadm utility can be applied only to interfaces that are part of an IP multipathing group.
OPTIONS
The if_mpadm utility supports the following options:
-d interface_name Detach or off-line the interface specified by interface_name.
-r interface_name Reattach or undo the previous detach or off-line operation on the interface specified by interface_name. Unless
the -d option was used to detach or off-line the interface, this option will fail.
EXAMPLES
Example 1: Detaching an Interface
Use the following command to off-line or detach the interface. All network access will failover from hme0 to other interfaces in the same
IP multipathing group. If no other interfaces are in the same group, the operation will fail.
example% if_mpadm -d hme0
Example 2: Reattaching an Off-line Interface
Use the following command to undo the previous operation. Network access will failback to hme0.
example% if_mpdadm -r hme0
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Availability |SUNWcsu |
+-----------------------------+-----------------------------+
|Interface Stability |Unstable |
+-----------------------------+-----------------------------+
SEE ALSO
ifconfig(1M), in.mpathd(1M), attributes(5)
DIAGNOSTICS
off-line failed as there is no other functional interface available in the multipathing group for failing over the network access.
This message means that other interfaces in the group are failed over already or the multipathing configuration was not suitable for com-
pleting a failover.
off-line cannot be undone because multipathing configuration is not consistent across all the interfaces in the group.
This message means that some interfaces in the IP multipathing group are not configured consistently with other interfaces in the group,
for example, one of the interfaces in the group does not have an IFF_NOFAILOVER address.
SunOS 5.10 3 Sep 2002 if_mpadm(1M)