06-05-2008
9 More Discussions You Might Find Interesting
1. Solaris
I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies
2. Solaris
Hi,
I have a root with hardware RAID on c0t0d0 and c0t2d0. I would like to set the boot device sequence in OBP for both hdds.
I have checked in ls -l /dev/rdsk/ for the path of c0t2d0 but it does not exist. Can anyone shed some lights on this?
AVAILABLE DISK SELECTIONS:
0.... (12 Replies)
Discussion started by: honmin
12 Replies
3. Solaris
Hi,
I have problem creating hardware raid on T5120 with 4 disks. After the hardware raid 1 created, then I used the raidctl -l c1t0d0 and raidctl -l c1t2d0
the output of volume c1t0d0 contain disk 0.0.0 0.1.0, also the volume c1t2d0 contain disk 0.0.0 0.1.0 and should be 0.2.0 0.3.0
so I... (15 Replies)
Discussion started by: netlink
15 Replies
4. Solaris
Hi everyone
I've just purchased a Sun T5120 server with 2 internal disks. I've configured hardware RAID (mirror) and as a result the device tree in Solaris only contains 1 hard drive.
My question is, how would I know when one of the drives become faulty?
Thanks (2 Replies)
Discussion started by: soliberus
2 Replies
5. UNIX for Dummies Questions & Answers
Hi
Can someone tell me what are the differences between software and hardware raid ?
thx for help. (2 Replies)
Discussion started by: presul
2 Replies
6. Hardware
Hi all
I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS.
The documentation doesn't make it clear if:
1. The... (6 Replies)
Discussion started by: soliberus
6 Replies
7. Solaris
Server Model: T5120 with 146G x4 disks.
OS: Solaris 10 - installed on c1t0d0.
Plan to use software raid (veritas volume mgr) on c1t2d0 disk.
After format and label the disk, still not able to detect using vxdiskadm.
Question:
Should I remove the hardware raid on c1t2d0 first?
My... (4 Replies)
Discussion started by: KhawHL
4 Replies
8. Solaris
Dear All ,
we have hardware raid 1 implemented on Solaris Disks.
We need to patch the Servers. Kindly let me know how to patch hardware raid implemented Servers.
Thanks...
Rj (7 Replies)
Discussion started by: jegaraman
7 Replies
9. Solaris
Dear All ,
Pl find the below command ,
# raidctl -l
Controller: 1
Volume:c1t0d0
Disk: 0.0.0
Disk: 0.1.0
Disk: 0.3.0
#
raidctl -l c1t0d0
Volume Size Stripe Status Cache RAID
Sub Size ... (10 Replies)
Discussion started by: jegaraman
10 Replies
LEARN ABOUT OPENSOLARIS
lsimega
lsimega(7D) lsimega(7D)
NAME
lsimega - SCSI HBA driver for LSI MegaRAID 320-2x SCSI RAID Controller
The lsimega SCSI RAID host bus adapter driver is a SCSA-compliant nexus driver that supports LSI MegaRAID 320-2x SCSI RAID devices.
The lsimega driver supports standard functions provided by the SCSA interface, including RAID disk I/O and passthrough I/O to support
SCSI tape and CDROM.
DRIVER CONFIGURATION
The lsimega.conf file contains no user configurable parameters. Please configure your hardware through BIOS.
The LSI MegaRAID 320-2x device can support up to 40 logic drivers. Note that BIOS numbers the logic drives as 1 through 40, however in
Solaris these drives are numbered from 0 to 39.
See attributes(5) for a description of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Availability | |
+-----------------------------+-----------------------------+
FILES
/kernel/drv/lsimega
32-bit ELF kernel module.
/kernel/drv/amd64/lsimega
64-bit kernel module ( only).
/kernel/drv/lsimega.conf
Driver configuration file (contains no user-configurable options).
prtconf(1M), attributes(5), amr(7D), scsi_hba_attach(9F), scsi_sync_pkt(9F), scsi_transport(9F), scsi_inquiry(9S), scsi_device(9S),
scsi_pkt(9S)
Small Computer System Interface-2 (SCSI-2)
20 April 2005 lsimega(7D)