on solaris 10:
dladm show-dev
dladm show-link
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

No NIC Card?

Hello Everyone, While trying to configure my network interface card on my system which runs mandrake 7, I have faced many problems. I used commands like netconf, drakconf, ifconfig etc to configure my NIC but of no use. There is no output for dmesg|grep eth. Does that mean that mandrake... (2 Replies)
Discussion started by: cyno
2 Replies

2. HP-UX

configuring nic card

using sam i have tryed to configure the nic, however when i try to do so i get an error saying i couldn't as i was using BIND ? (0 Replies)
Discussion started by: bobstar01
0 Replies

3. Linux

Howto Detect New Nic Card

Hi PPL! I have P-IV processor, with on-board NIC card. I have added one more NIC card for domestic use. My kudzu does not recognise the newly added PCMCIA NIC card. How to go about this one? Suggest PEnguin (0 Replies)
Discussion started by: chakri.penguin
0 Replies

4. HP-UX

how can I determine which NIC card is virtual NIC Card

how can I determine which NIC card is virtual NIC Card which condition can make a decision Does HP UX have Virtual Network Adapter Concept if ,it has where I can Find if I Install Virutal Network Adapter or which command that i can get it or which software can generate thanks (2 Replies)
Discussion started by: alert0919
2 Replies

5. Solaris

Reg. NIC card

Hi friends i have problem with my home pc, i installed solaris 10 but my lan drivers are not installed, if i want to install drivers manually from where to download and how to install. I have Realtech lan card. when i type ifconfig -a it shows only localhost 127.0.0.0 Lo0 cannot see other than... (5 Replies)
Discussion started by: kurva
5 Replies

6. Solaris

NIC card repetative Failover

I have configure 2 NIC in ipmp group1 .Similarly other 2 NIC in ipmp group2 When I connect both NIC to 2 different switch , which is connect to one L3 switch as trunk. Both the NIC failover to each other continously. Following are the message log. ifmsdb1 in.mpathd: NIC failure detected... (0 Replies)
Discussion started by: abhaymittal003
0 Replies

7. Linux

How to check which NIC Card is used for backups?

I have a linux box with 2 nic cards on it one for prod and one for backup. My question is while the backup are happening how do I determine which nic is used for backups . I would like to run a command so that that I can see the usage in a dynamic fashion. (7 Replies)
Discussion started by: new2prog
7 Replies

8. AIX

AIX -How to find which NIC is on which PCI card

Hi All, How can I find out which is ETH5 on my AIX P5 system. I have about seven different NIC card on this. I did move the cable to each one but still I was not able to see the link light up when I did netstat -v Any idea? Thanks. (2 Replies)
Discussion started by: samnyc
2 Replies

9. HP-UX

NIC card issue

Hi, Someone asked me the below. If the box has multiple NIC cards, try to run a test with interface address specified as shown below $ java utils.MulticastTest -N server100 -A 237.155.155.1 -i <interfaceaddress> How can I now find out if my box has multiple NIC cards and how can I... (5 Replies)
Discussion started by: mohtashims
5 Replies

10. Red Hat

Finding speed of NIC Card

Hi, I would like to know how to find out ACTUAL speed of NIC Card. I have used the command ethtool eth0, it is showing supported modes, but what is acutal speed ? how to find out? (4 Replies)
Discussion started by: manoj.solaris
4 Replies
dladm(1M)																 dladm(1M)

NAME
dladm - configure data-link interfaces SYNOPSIS
dladm show-link [-s [-i interval]] [-p] [name] dladm show-dev [-s [-i interval]] [-p] [dev] dladm create-aggr [-t] [-R root-dir] [-P policy] [-l mode] [-T time] [-u address] -d dev [-d dev] ... key dladm delete-aggr [-t] [-R root-dir] key dladm add-aggr [-t] [-R root-dir] -d dev [-d dev] ... key dladm remove-aggr [-t] [-R root-dir] -d dev [-d dev] ... key dladm modify-aggr [-t] [-R root-dir] [-P policy] [-l mode] [-T time] [-u address] key dladm show-aggr [-L] [-s [-i interval]] [-p] [key] dladm -? The dladm command is used to configure data-links. A configured data-link is represented in the system as a STREAMS DLPI (v2) interface which may be plumbed under protocol stacks such as TCP/IP. Each data-link relies on either a single network device or an aggregation of devices to send packets to or receive packets from a network. The dladm command operates on the following kinds of object: link Data-links, identified by a name aggr Aggregations of network devices, identified by a key dev Network devices, identified by concatenation of a driver name and an instance number Some devices do not support configurable data-links or aggregations. The fixed data-links provided by such devices can be viewed using dladm, but can not be configured. SUBCOMMANDS The following subcommands are supported: show-link Show configuration information for all data-links or the specified data-link. By default, the system is configured to have one data-link for each known network device. show-dev Shows information for all devices or the specified device. create-aggr Creates an aggregation using the given key value from as many dev objects as are specified. A data-link is created by default, and is given a name which is the concatenation of "aggr" and the key value of the aggregation. delete-aggr Deletes the specified aggregation. add-aggr Adds as many dev objects as are specified to the given aggregation. remove-aggr Removes as many dev objects as are specified from the given aggregation. modify-aggr Modifies the parameters of the given aggregation. show-aggr Shows configuration information for all aggregations or the specified aggregation. The following options are supported: -k key --key=key The key of an aggregation. This must be an integer value between 1 and 999. -d dev --dev=dev A device specifier. This must be a concatenation of the name and instance of the driver bound to the device. -P policy --policy=policy Specifies the port selection policy to use for load spreading of outbound traffic. The policy specifies which dev object is used to send packets. A policy consists of a list of one or more layers specifiers separated by commas. A layer specifier is one of the follow- ing: L2 Select outbound device according to source and destination MAC addresses of the packet. L3 Select outbound device according to source and destination IP addresses of the packet. L4 Select outbound device according to the upper layer protocol information contained in the packet. For TCP and UDP, this includes source and destination ports. For IPsec, this includes the SPI (Security Parameters Index.) For example, to use upper layer protocol information, the following policy can be used: -P L4 To use the source and destination MAC addresses as well as the source and destination IP addresses, the following policy can be used: -P L2,L3 -l mode --lacp-mode=mode Specifies whether LACP should be used and, if used, the mode in which it should operate. Legal values are off, active or passive. -T time --lacp-timer=time Specifies the LACP timer value. The legal values are short or long. -u address --unicast=address Specifies a fixed unicast address to be used for the aggregation. If this option is not specified then an address is automatically cho- sen from the set of addresses of the component devices. -L --lacp Specifies whether detailed LACP information should be displayed. -s --statistics Used with the show-link, show-aggr, or show-dev subcommands to show the statistics of data-links, aggregations or devices, respec- tively. -i interval --interval=interval Used with the -s option to specify an interval, in seconds, at which statistics should be displayed. If this option is not specified, statistics will only be displayed once. -t --temporary Specifies that the change is temporary. Temporary changes last until the next reboot. -R root-dir --root-dir=root-dir Specifies an alternate root directory where dladm applies changes. This can be useful in JumpStart scripts, where the root directory of the system being modified is mounted elsewhere. -p --parseable Specifies that configuration information should be displayed in parseable format. -? --help Displays help information. (Stops interpretation of subsequent arguments). EXAMPLES
Example 1: Configuring an aggregation To configure a data-link over an aggregation of devices bge0 and bge1 with key 1, enter the following command: # dladm create-aggr -d bge0 bge1 1 See attributes(5) for descriptions of the following attributes: /usr/sbin +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsu | +-----------------------------+-----------------------------+ |Interface Stability |Evolving | +-----------------------------+-----------------------------+ /sbin +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsr | +-----------------------------+-----------------------------+ |Interface Stability |Evolving | +-----------------------------+-----------------------------+ ifconfig(1M), attributes(5), dlpi(7P) NOTES
The configuration of all objects will persist across reboot. 28 Sep 2005 dladm(1M)