Just saw Solaris 8 in the list. Let me try reading it, Thanks much
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Disk Array & Clustering

Sorry if this is not the right folder... I come across these terms.. -Disk Array -Clustering What are they? When and how will we use them? Please teach me. Thanks (1 Reply)
Discussion started by: champion
1 Replies

2. UNIX for Advanced & Expert Users

Help: Sun Disk partitioning for Sun V240 & StorEdge 3300

Dear Sun gurus, I have Sun Fire V240 server with its StorEdge 3300 disk-array. Following are its disks appeared in format command. I have prepared its partitions thru format and metainit & metattach (may be i have made wrong steps, causing the errors below because I have done thru some document... (1 Reply)
Discussion started by: shafeeq
1 Replies

3. Solaris

Using Enterprise 4500 with storedge D100 and storedge A5200

Sorry if this seems trivial. i have been given a task at work to configure a sun processing server "enterprise 4500" so it can work with the a storage server "storedge A5200" and "storedge D1000" the truth is i have never worked on a sun server before. i need a guideline (step by step) as to... (5 Replies)
Discussion started by: lawalidowu
5 Replies

4. UNIX for Advanced & Expert Users

3510 Disk Array Problem

I have a 3510 disk array attached to a T2000 server. The dmesg command shows disk error as follows and is generated a couple of times during the day Aug 18 03:35:51 myserver SUNWscsdMonitor: <rctrl6042> Standard General Event, CHL:2 ID:22 Drive NOTICE: Drive Recovered Error - 5F8E1F... (1 Reply)
Discussion started by: Tirmazi
1 Replies

5. Solaris

Add new disk to Sun StorEdge 3310 RAID

HI guys. Bit of a noob so bear with me. I have 2 new disks I want to add to my StorEdge 3310 but am getting lost in the steps. We have another 3310 (JBOD) that I was able to plug the disks into and they instantly showed up. Did a few minor commands after (drvconfig, devfsadm etc..) and I was... (4 Replies)
Discussion started by: jamie_collins
4 Replies

6. Solaris

D1000 Storedge array connection

I am trying to connect D1000 storedge with my sun blade 1500 and i am getting the following error when booting the system. Oct 13 22:21:56 brampton rpcbind: rpcbind terminating on signal. Oct 13 22:22:02 brampton syseventd: SIGHUP caught - reloading modules Oct 13 22:22:02 brampton... (9 Replies)
Discussion started by: mnathan
9 Replies

7. Solaris

Disk Array

So I have 2 solaris sun servers one with a disk array with 14 drives which I need to move to the other server. How do I move the disk array configured as a Raid 5 to another server without losing data? So far I know I'll connect the drive, run devfsadm, use format to verify the server see's... (5 Replies)
Discussion started by: Kjons76
5 Replies

8. UNIX for Advanced & Expert Users

Disk Array

HI: I have a DUAL redundant system running in HP-UX 10.20 ( 2 servers) Both servers share an external SCSI disk array. Both server runs a Data base wich uses the disk array to write the data, and that is the way they share the information. The way that the servers see the disk array, is like... (1 Reply)
Discussion started by: pmoren
1 Replies

9. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

10. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies
suninstall(1M)						  System Administration Commands					    suninstall(1M)

NAME
suninstall - install the Solaris operating system SYNOPSIS
suninstall DESCRIPTION
install-solaris(1M) is now the preferred command for starting and restarting the Solaris Installation program. It should be used instead of suninstall. suninstall is symbolically linked to install-solaris. suninstall is a forms-based and graphical subsystem for installing the operating system. suninstall exists only on the Solaris installation media (CD or DVD) and should only be invoked from there. Refer to the Solaris 10 Instal- lation Guide: Basic Installations for more details. suninstall allows installation of the operating system onto any standalone system. suninstall loads the software available on the installa- tion media. Refer to the Solaris 10 Installation Guide: Basic Installations for disk space requirements. USAGE
Refer to the Solaris 10 Installation Guide: Basic Installations for more information on the various menus and selections. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcdrom (Solaris instal- | | |lation media) | +-----------------------------+-----------------------------+ SEE ALSO
pkginfo(1), install(1M), install-solaris(1M), pkgadd(1M), attributes(5) Solaris 10 Installation Guide: Basic Installations NOTES
It is advisable to exit suninstall by means of the exit options in the suninstall menus. SunOS 5.10 9 Sep 2004 suninstall(1M)
All times are GMT -4. The time now is 08:24 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy