Operating Systems Solaris Powering ON SUN 450 Enterprise Post 302186270 by calsum on Thursday 17th of April 2008 12:00:19 AM
Old 04-17-2008
Lightbulb Powering ON SUN 450 Enterprise

Problem powering ON the SUN 450 E, we checked voltage and the power supply. Seems to be we have out of 3 LED's in the back 2 are glowing, when we turn the power button on the front from standby to ON.

Does anyone know how to troubleshoot this?.

I have looked through some troubleshooting documentation from SUN, tried removing all PCI slots and DMM's while starting.

Any help is appreciated!

Thanks
 

8 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Enterprise 450 Solaris 9 Problems

I am just getting started loading an Enterprise 450 Dell with Solaris 9 however I cannot get out of a loop that is not letting me get started. My basic question is what are the key strokes to get you out of a boot sequence so that you can at least clear the hard drive or start an install ... (9 Replies)
Discussion started by: Joe7778
9 Replies

2. Solaris

Sun ultra enterprise 450 server does not power on

Hi, I have a sun ultra enterprise 450 server. There is no power supply to the peripheral components. Can anyone suggest what might be the problem with the server? What do i have to check for? I am new to the solaris and server world. Please suggest in detail. :) Thanks, Ashwini (5 Replies)
Discussion started by: tgashwini
5 Replies

3. Solaris

Problem booting Sun ultra enterprise 450 server

Hi, I have a sun ultra enterprise 450 server. This server powers on and a white screen appears with the system and network information. But it doesnot boot up completely. Booting operation wil be halted by a warning: \usr\sbin\fsck not found. Most likely the mount of \usr failed or the... (5 Replies)
Discussion started by: tgashwini
5 Replies

4. Solaris

Usb to serial connection to Sun Enterprice 450

Hi all, I must connect my PC (Windows 2000) to Sun Enterprise 450 (4 X UltraSPARC-II 400Mhz) for Solaris 10 Installation. My PC doesn't have a serial port therefore I must use USB port. How can I connect USB port of my PC to the serial port (DB 25) of Sun 450? Will be there any problems with... (3 Replies)
Discussion started by: Sunb3
3 Replies

5. UNIX for Dummies Questions & Answers

Sun ultra enterprise 450 power issue

I've search the forum and came up with someone having the same issue where the power does not going to the main board. I turn the key and nothing, no lights or anything moving. I have another board put it in the same system and it works just fine. Please help, thank you in advance. (2 Replies)
Discussion started by: vhtran
2 Replies

6. Solaris

Sun Enterprise 420R

I am trying to connect to our Sun Enterprise 420R server via Hyperterminal. Using settings of 9600,n,1,n, I am getting nothing on COM4 (my laptop's ethernet port). I've also tried COM3, COM2, and COM5 - but at least I can type in COM4: the other three I cannot type when trying to connect. I am... (2 Replies)
Discussion started by: jmcgranahan
2 Replies

7. Solaris

Help with Stubborn Sun Ultra Enterprise 450

Hello everyone...yesterday i've received a Sun Ultra E450 Server Unit and when I try to boot from everything it asks me for Firmware Password.:rolleyes: The unit hasn't been used for 10 years...so no one doesn't yet remember the password.:D Ok,I've searched on the Internet all day long finding... (5 Replies)
Discussion started by: Daiman
5 Replies

8. Solaris

Sun Fire 4800 is not powering-on

I switched on the power to the server. But, the server did not power on i.e., none of the 3 LEDs on the front panel is lighted. (Power supplies are showing only amber LEDs with "Ready to remove" sign). I tried to turn on the power supplies via System Controller menu (platform shell), but it... (6 Replies)
Discussion started by: solind
6 Replies
ups_conf(4)						     Kernel Interfaces Manual						       ups_conf(4)

NAME
ups_conf - HP PowerTrust Uninterruptible Power System (UPS) monitor configuration file DESCRIPTION
The default configuration file for the HP PowerTrust UPS monitor daemon Another file can be used as long as it complies with the specified format, and the monitor daemon is configured to use the alternate file (see the description of the option in ups_mond(1M)). Lines in the configuration file can contain a maximum of 256 characters, and the full pathname of a UPS-tty device file can contain a maxi- mum of 100 characters. Only one entry per line is allowed in the configuration file. Each line begins with a keyword. All fields in configuration file entries are delimited by colons (:). Entries in the configuration file end with the first space encountered (as specified by the library function, see isspace(3C)). Characters beyond the first space on each line are treated as comments. The shutdown delay and timeout values should be the first lines in the file. Entries in this file begin with keywords that must appear exactly as shown below. The terminating colon separates the keyword from the value of its parameter. recognizes the following keywords: The number of minutes following notification by the first that its corresponding UPS is operating on internal (battery) power, before initiates The default is one minute. This value should be set to account for transient power interruptions, if they are common to the site. The number of minutes to monitor the operation before initiating with the halt option see reboot(2)). The default is five minutes. This value should be longer than the longest time the system requires to execute shutdown(1M). Note that after the value of has elapsed, a UPS lacking AC line voltage will power off. When AC line voltage is restored, the UPS will restore power to its output. This timeout value should not be so much longer than that an observer may become impatient. It is important to note that this value is the period for which the UPS will delay its power-cycling, even if AC power is restored sooner. This line is followed by either or which indicates if the UPS needs to be turned OFF or ON upon AC line voltage failures respectively. Default is The full pathname of the device special file through which the UPS is configured. Include one entry for each UPS. entries are handled in the order they appear in Therefore, it is important to list your uninterruptible power systems in order of priority (for example, UPS protecting the SPU listed first). entries can contain following optional parameters, which can appear in any order following the device special file name: This will not cause or to be initiated. The type of uninterruptible power supply. Currently, this is the only type defined and supports the entire HP UPS family, including PowerTrust. It defaults to SOLA . EXAMPLES
The following is a sample file: FILES
SEE ALSO
ups_mond(1M). ups_conf(4)
All times are GMT -4. The time now is 04:24 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy