Sponsored Content
Operating Systems Solaris How to force the IP address working right now? Post 302177376 by trantuananh24hg on Thursday 20th of March 2008 10:05:34 PM
Old 03-20-2008
Quote:
Originally Posted by simquest
You need to plumb your card first
ifconfig ce0 plumb
after, configure your ip address
ifconfig ce0 190.10.10.66/16 up
try to ping your ip from the same system
ping 190.10.10.66
and try to ping another system after.

Look if your have 2 nic on the system.
Thank you, but I did not ping to the other system.
This is the result from plumb:
Code:
#ifconfig ce0 plumb
ifconfig : SIOCSLIFNAME for ip : ce0 : already exists 
#ifconfig ce0 190.10.10.66/16 up
#ping 190.10.10.68
ICMP Host Unreachable from gateway database (190.10.10.66)
...

database is my host name

-----------------------
Quote:
Originally Posted by DukeNuke2
if you are on solaris 10 please post also the output of

dladm show-dev
and
dladm show-link
Thank you, I am using Solaris 10 on V890 Sparc, and the result from your command are:
Code:
#dladm show-dev
ge0       link:unknown   speed:0    Mbps   duplex:unknown
eri0       link:unknown   speed:0    Mbps   duplex:unknown
ce0       link:unknown   speed:0    Mbps   duplex:unknown


#dladm show-link
ge0       type:legacy     mtu:1800      device:ge0
eri0       type:legacy     mtu:1800      device:eri0
ce0       type:legacy     mtu:1800      device:ce0

The NIC I already use is ce0.

Thank again!

Last edited by trantuananh24hg; 03-20-2008 at 11:15 PM..
 

10 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

BCC address not working (mimesender)

I modified the following mimesender script so I can send also to BCC adresses: https://www.unix.com/showthread.php?t=17065 Everything is working and correct. Except the email address(es) in BCC are not delivered. When I set the debug-mode ON I can see the BCC header and when I receive the... (1 Reply)
Discussion started by: michaelv
1 Replies

2. UNIX for Dummies Questions & Answers

Panic kernal-mode address fault on user address 0x14

:) Firstly Hi all!!, im NEW!! and on here hoping that someone might be able to offer me some help... i have a server that keeps crashing every few days with the error message: PANIC KERNAL-MODE ADDRESS FAULT ON USER ADDRESS 0X14 KERNAL PAGE FAULT FROM (CS:EIP)=(100:EF71B5BD) EAX=EF822000... (10 Replies)
Discussion started by: Twix
10 Replies

3. UNIX for Advanced & Expert Users

netlink: NLM_F_REPLACE not working on address???

Am I missing something, or does RFC 3549 suggest that the NLM_F_REPLACE flag should apply to any netlink message header? In other words, routes/links/ipv6-lifetimes should not be the only things that can be affected by the flag. The reason I ask is that it seems impossible (from looking at the... (0 Replies)
Discussion started by: jjinno
0 Replies

4. IP Networking

Tracing a MAC address to IP address: Solaris

Hi there I lost connectivity to one of our remote systems and when I checked the messages log I found the following: Aug 10 23:42:34 host xntpd: time reset (step) 1.681729 s Aug 16 13:20:51 host ip: WARNING: node "mac address" is using our IP address x.x.x.x on aggr1 Aug 16 13:20:51 host... (9 Replies)
Discussion started by: notreallyhere
9 Replies

5. Solaris

How to force Sendmail to Rewrite Sender Address?

Need to change sender email id from applmgr@<hostname>.<domain-name> to applmgr@domain-name. Understand we can change in the sendmail.cf where $j is the hostname.domain-name.. can anyone show the exact value to change? Thank you. (8 Replies)
Discussion started by: KhawHL
8 Replies

6. Shell Programming and Scripting

Search IP Address in list of ranges -- not working great

I have been struggling with a script to automate some security related activities. I have it pretty much working, all except the search. I have an input file formatted as such: 216.234.246.158 216.234.246.158 `` 24.249.221.22 24.249.221.200 `` 24.249.226.0 ... (4 Replies)
Discussion started by: tsunami4u
4 Replies

7. UNIX for Advanced & Expert Users

C program to detect duplicate ip address if any after assigning ip address to ethernet interface

Hi , Could someone let me know how to detect duplicate ip address after assigning ip address to ethernet interface using c program (3 Replies)
Discussion started by: Gopi Krishna P
3 Replies

8. Shell Programming and Scripting

Sed: deleting last line prevents '$' address from working in the multi-script invocation

It looks like if matching and deleting the last line confuses 'sed' so it does not recognize '$' address. Consider: sed -e '/^3/d' -e '$ a text' supposed to delete a line starting with '3' and then append 'text' after the last line of input. But, if it is the last line of input which starts... (2 Replies)
Discussion started by: msz59
2 Replies

9. UNIX for Beginners Questions & Answers

Mail command not working for Long Email Address with Dashes

My company has an email user group email address name that has 35 characters in front of the @ symbol where two of them are dashes. For some reason the mail command fails to send email to this address when I invoke it from the Linux command line. I don't understand the reason for the failure. Below... (5 Replies)
Discussion started by: Phil44
5 Replies

10. Shell Programming and Scripting

Grep -w ip address from a file isnt working need help

I have a file "file1" that contains several ip address , and the "file2" contains several records , each line in file2 contains somewhere the ip address that i am searching in the file1 I use the unix command grep -w for i in `cat file1` do grep -w "$i" file2 >> file3 done ... (9 Replies)
Discussion started by: knijjar
9 Replies
dladm(1M)																 dladm(1M)

NAME
dladm - configure data-link interfaces SYNOPSIS
dladm show-link [-s [-i interval]] [-p] [name] dladm show-dev [-s [-i interval]] [-p] [dev] dladm create-aggr [-t] [-R root-dir] [-P policy] [-l mode] [-T time] [-u address] -d dev [-d dev] ... key dladm delete-aggr [-t] [-R root-dir] key dladm add-aggr [-t] [-R root-dir] -d dev [-d dev] ... key dladm remove-aggr [-t] [-R root-dir] -d dev [-d dev] ... key dladm modify-aggr [-t] [-R root-dir] [-P policy] [-l mode] [-T time] [-u address] key dladm show-aggr [-L] [-s [-i interval]] [-p] [key] dladm -? The dladm command is used to configure data-links. A configured data-link is represented in the system as a STREAMS DLPI (v2) interface which may be plumbed under protocol stacks such as TCP/IP. Each data-link relies on either a single network device or an aggregation of devices to send packets to or receive packets from a network. The dladm command operates on the following kinds of object: link Data-links, identified by a name aggr Aggregations of network devices, identified by a key dev Network devices, identified by concatenation of a driver name and an instance number Some devices do not support configurable data-links or aggregations. The fixed data-links provided by such devices can be viewed using dladm, but can not be configured. SUBCOMMANDS The following subcommands are supported: show-link Show configuration information for all data-links or the specified data-link. By default, the system is configured to have one data-link for each known network device. show-dev Shows information for all devices or the specified device. create-aggr Creates an aggregation using the given key value from as many dev objects as are specified. A data-link is created by default, and is given a name which is the concatenation of "aggr" and the key value of the aggregation. delete-aggr Deletes the specified aggregation. add-aggr Adds as many dev objects as are specified to the given aggregation. remove-aggr Removes as many dev objects as are specified from the given aggregation. modify-aggr Modifies the parameters of the given aggregation. show-aggr Shows configuration information for all aggregations or the specified aggregation. The following options are supported: -k key --key=key The key of an aggregation. This must be an integer value between 1 and 999. -d dev --dev=dev A device specifier. This must be a concatenation of the name and instance of the driver bound to the device. -P policy --policy=policy Specifies the port selection policy to use for load spreading of outbound traffic. The policy specifies which dev object is used to send packets. A policy consists of a list of one or more layers specifiers separated by commas. A layer specifier is one of the follow- ing: L2 Select outbound device according to source and destination MAC addresses of the packet. L3 Select outbound device according to source and destination IP addresses of the packet. L4 Select outbound device according to the upper layer protocol information contained in the packet. For TCP and UDP, this includes source and destination ports. For IPsec, this includes the SPI (Security Parameters Index.) For example, to use upper layer protocol information, the following policy can be used: -P L4 To use the source and destination MAC addresses as well as the source and destination IP addresses, the following policy can be used: -P L2,L3 -l mode --lacp-mode=mode Specifies whether LACP should be used and, if used, the mode in which it should operate. Legal values are off, active or passive. -T time --lacp-timer=time Specifies the LACP timer value. The legal values are short or long. -u address --unicast=address Specifies a fixed unicast address to be used for the aggregation. If this option is not specified then an address is automatically cho- sen from the set of addresses of the component devices. -L --lacp Specifies whether detailed LACP information should be displayed. -s --statistics Used with the show-link, show-aggr, or show-dev subcommands to show the statistics of data-links, aggregations or devices, respec- tively. -i interval --interval=interval Used with the -s option to specify an interval, in seconds, at which statistics should be displayed. If this option is not specified, statistics will only be displayed once. -t --temporary Specifies that the change is temporary. Temporary changes last until the next reboot. -R root-dir --root-dir=root-dir Specifies an alternate root directory where dladm applies changes. This can be useful in JumpStart scripts, where the root directory of the system being modified is mounted elsewhere. -p --parseable Specifies that configuration information should be displayed in parseable format. -? --help Displays help information. (Stops interpretation of subsequent arguments). EXAMPLES
Example 1: Configuring an aggregation To configure a data-link over an aggregation of devices bge0 and bge1 with key 1, enter the following command: # dladm create-aggr -d bge0 bge1 1 See attributes(5) for descriptions of the following attributes: /usr/sbin +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsu | +-----------------------------+-----------------------------+ |Interface Stability |Evolving | +-----------------------------+-----------------------------+ /sbin +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsr | +-----------------------------+-----------------------------+ |Interface Stability |Evolving | +-----------------------------+-----------------------------+ ifconfig(1M), attributes(5), dlpi(7P) NOTES
The configuration of all objects will persist across reboot. 28 Sep 2005 dladm(1M)
All times are GMT -4. The time now is 08:33 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy