Sponsored Content
Full Discussion: Hardware RAID
Operating Systems Solaris Hardware RAID Post 302157484 by DukeNuke2 on Friday 11th of January 2008 04:36:00 AM
Old 01-11-2008
Quote:
Originally Posted by moofoo
hello there,
there are a few sun sparc server which "allready" support hardware raids
for instance FireT1000, T2000, T5120 or T5220. (setup done with the raidctl command). Also as allready mentioned above raidz (zfs raid) is a good alternative to that.
cheers
but (afaik) this is not a real hardware raid! better use an external raid-box with fcal or scsi controller...
 

9 More Discussions You Might Find Interesting

1. Solaris

how to hardware RAID 1 on T5120

Hi, I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1" The System did come preinstalled as it comes from sun. I did not do much on it. I booted system using boot cdrom -s gave format... (6 Replies)
Discussion started by: upengan78
6 Replies

2. Solaris

T2000 Hardware RAID

Hi, I have a root with hardware RAID on c0t0d0 and c0t2d0. I would like to set the boot device sequence in OBP for both hdds. I have checked in ls -l /dev/rdsk/ for the path of c0t2d0 but it does not exist. Can anyone shed some lights on this? AVAILABLE DISK SELECTIONS: 0.... (12 Replies)
Discussion started by: honmin
12 Replies

3. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

4. Solaris

Hardware Raid - LiveUpgrade

Hi, I have a question. Do LiveUpgrade supports hardware raid? How to choose the configuration of the system disk for Solaris 10 SPARC? 1st Hardware RAID-1 and UFS 2nd Hardware RAID-1 and ZFS 3rd SVM - UFS and RAID1 4th Software RAID-1 and ZFS I care about this in the future to take... (1 Reply)
Discussion started by: bieszczaders
1 Replies

5. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

6. HP-UX

Hardware RAID in HP Unix rp3440

Hi Gurus, Can anyone tell me the Hardware RAID configuration in HP Unix rp3440 model server containing HP UX B.11.11 OS version. Thanks in Advance. BR, Prasanth (3 Replies)
Discussion started by: prasanth438
3 Replies

7. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

8. Solaris

Hardware raid patching

Dear All , we have hardware raid 1 implemented on Solaris Disks. We need to patch the Servers. Kindly let me know how to patch hardware raid implemented Servers. Thanks... Rj (7 Replies)
Discussion started by: jegaraman
7 Replies

9. Solaris

Hardware RAID using three disks

Dear All , Pl find the below command , # raidctl -l Controller: 1 Volume:c1t0d0 Disk: 0.0.0 Disk: 0.1.0 Disk: 0.3.0 # raidctl -l c1t0d0 Volume Size Stripe Status Cache RAID Sub Size ... (10 Replies)
Discussion started by: jegaraman
10 Replies
iobind(1M)																iobind(1M)

NAME
iobind - bind a driver to a device SYNOPSIS
instance] DESCRIPTION
The command may be used to perform online unbinding of a device LUN hardware path from its current driver and binding a new driver to it. As part of the binding operation, the specified driver will be bound to the LUN hardware path and also to its corresponding legacy hardware paths. The hardware path specified as the argument to the option must be of the form 64000/0x/0x. The driver name specified with the option will be bound to the LUN and legacy hardware paths. The optional option specifies an instance number to be assigned to the device associated with the hardware path. If this option is not used, the device will be assigned a new instance number in the new driver's class. The optional forces the binding to occur at the next reboot if it cannot be done online. The device must not be in use while the unbind operation is performed. The driver must support online unbinding and binding. If either of these requirements is false and the option is not given, the user will be asked if the binding can take effect at the next reboot. The user is given the option to proceed or not. If a driver supports online unbinding and binding, then after completes, a device will have one of the following software states as shown by the command: The specified driver was successfully bound to the hardware path. The specified driver cannot be used to claim the hardware at the specified hardware path. The device at the address is responding, but it is in an error state. The device at the specified hardware path is no longer responding. The specified hardware path is locked. Try again later. The driver failed. Options recognizes the following options: Force the binding even though a driver does not support online unbinding and binding or the device is in use. In this case, the binding will take effect at the next reboot. The LUN hardware path of a device must be of the form 64000/0x/0x. The instance number to be assigned to the device. The name of the driver that the LUN and legacy hardware paths are to be bound to. RETURN VALUE
Exit values are: Successful completion. An error condition occurred. EXAMPLES
Unbind the driver bound to the device at hardware path and bind the device to Use the default instance number of the driver's class. Unbind the driver bound to the device at hardware path and bind the device to Assign it the instance number Do a forced binding. If the driver does not support online binding or the device is busy, the binding will be deferred till next reboot. WARNINGS
The and commands should not be run at the same time because both commands attempt to bind drivers. In particular, there may be a short window while will leave a hardware path unbound. If runs during that window, it may bind a different driver to that hardware path. If this happens, must be executed again to bind the desired driver. may be executed only by the superuser. SEE ALSO
ioscan(1M), intro(7). iobind(1M)