11-25-2007
Take a look at
the manpage of st_san_safe.
If your system isn't using SAN based tape backups, then perhaps you should turn off the parameter (set value to 0). You can do that through SAM - don't remember exactly how/where to navigate inside SAM.
edit
Also suggest that you give a relevant title to your posts. I have edited the current title from 'hi' to 'st_san_safe enabled'
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hi, how to create account with the following
be cron enabled
only accessible via sudo (1 Reply)
Discussion started by: vilves
1 Replies
2. IP Networking
how we can find whether net is enabled or not
with out using ping
is there anyway please guide me
thanku ,in advance
sree (1 Reply)
Discussion started by: phani_sree
1 Replies
3. UNIX for Dummies Questions & Answers
I'm having trouble setting up passwordless ssh; specifically - I can only setup 2 remote hosts because when I try to add another to my known_hosts file it just won't. More investigation reveals various errors relating to 'No space left on device'.
There is plenty of free disk space; user quotas... (9 Replies)
Discussion started by: dan-e
9 Replies
4. UNIX for Dummies Questions & Answers
Hi
i am having two linux machines M1 M2 ,where M1 is the main machine and the connector is M2 Radius services are installed in M2. i pulled M2 users which resides on /user/local/raddb/users to M1 .so that any changes made to user in M1 will be reflected in M2. now i am disabling a user from M1... (0 Replies)
Discussion started by: kalyankalyan
0 Replies
5. UNIX for Dummies Questions & Answers
Hi all,
i had 500 users how can i know whether user is disabled or enabled
Thanks,
kalyan (8 Replies)
Discussion started by: kalyan212
8 Replies
6. Solaris
Hi guys.
This may be a stupid question but I am trying to see if my Solaris 9 server has async i/o enabled...
Is there a quick way to determine this?
Thanks in advance. (1 Reply)
Discussion started by: jamie_collins
1 Replies
7. Solaris
Hi,
Please let me know what is hardware watchdog enabled which we get when the solaris host is booting .As per my knowledge its the one states that the POST is enabled. correct me if am wrong. (1 Reply)
Discussion started by: rogerben
1 Replies
8. Linux
Hi
when I run the following GET commad:
./snmpget -m ALL -M /data/net/naamab/snmp/snmp_mib/ -v 3 -a MD5 -l authPriv -u test1 -A welcome1 -x DES -X privpass 127.0.0.1 NOVELSAT-MODULATOR-MIB::nsModLineCMMode.0 -d
I get the error:
Encryption support not enabled.
snmpget: USM encryption... (1 Reply)
Discussion started by: naamabm
1 Replies
9. Hardware
I'm getting this message using hpacucli in HP ProLiant BL460c G6. Raid controller is already enabled:
# hpacucli
HP Array Configuration Utility CLI 8.35-7.0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console.
=> ctrl all show... (0 Replies)
Discussion started by: linuxgeek
0 Replies
10. AIX
Hi,
I have a bit of a NFS problem on AiX 6.1 : When I set the mount to cio and dio - needed for a database app - Everything slows down. The following is copying 700mb, top one is a normal mount bottom one is a mount with the cio/dio option enabled :
# ./a.sh
Wed Jan 11 11:41:24 GMT 2012... (5 Replies)
Discussion started by: AJCG1976
5 Replies
LEARN ABOUT HPUX
hp9000s500
machid(1) General Commands Manual machid(1)
NAME
machid: hp9000s200, hp9000s300, hp9000s400, hp9000s500, hp9000s700, hp9000s800, hp-mc680x0, hp-pa, pdp11, u370, u3b, u3b10, u3b2, u3b5, vax
- provide truth value about processor type
SYNOPSIS
DESCRIPTION
The following commands return a true value (exit code 0) if the a processor type matches the command name. Otherwise a false value (exit
code nonzero) is returned. These commands are commonly used within makefiles and shell procedures to improve portability of applications
(see make(1)).
+-----------+-------------------------++--------+--------------------------+
|Command | True for ||Command | True for |
+-----------+-------------------------++--------+--------------------------+
|hp9000s200 | Series 200 ||pdp11 | PDP-11/45 or PDP-11/70 |
|hp9000s300 | Series 300 ||u3b | 3B20 computer |
|hp9000s400 | Series 400 ||u3b2 | 3B2 computer |
|hp9000s500 | Series 500 ||u3b5 | 3B5 computer |
|hp9000s700 | Series 700 ||u3b10 | 3B10 computer |
|hp9000s800 | Series 800 or 700 ||u370 | IBM System/370 computer |
|hp-mc680x0 | Series 200, 300, or 400 ||vax | VAX-11/750 or VAX-11/780 |
|hp-pa | Series 700 or 800 || | |
+-----------+-------------------------++--------+--------------------------+
EXAMPLES
Given a shell script that must behave differently when run on an HP 9000 Series 700 or 800 system, select the correct code segment to be
executed:
WARNINGS
always returns true on both Series 800 and Series 700 systems. Therefore, when using this command in scripts to determine hardware type,
always use both and in the appropriate sequence to ensure correct results (see
machid(1) will no longer provide support for future machines beyond the Series 800 and Series 700 systems. Decisions should be based on
the hardware and software configuration information returned by getconf(1).
SEE ALSO
getconf(1), make(1), sh(1), test(1), true(1).
machid(1)