Sponsored Content
Full Discussion: Disk replacement with svm
Operating Systems Solaris Disk replacement with svm Post 302119776 by Tornado on Thursday 31st of May 2007 09:58:14 PM
Old 05-31-2007
Quote:
Originally Posted by BG_JrAdmin
su25e1n: / # metastat -p

d100 -m d103 d113 1
d103 3 1 d102 \
1 d104 \
1 d106
d102 -p c0t11d0s0 -o 1 -b 2097152
d104 -p c0t11d0s0 -o 2097154 -b 2097152
d106 -p c0t11d0s0 -o 4194307 -b 2097152
d113 3 1 d112 \
1 d114 \
1 d116
d112 -p c0t12d0s0 -o 1 -b 2097152
d114 -p c0t12d0s0 -o 2097154 -b 2097152
d116 -p c0t12d0s0 -o 4194307 -b 2097152
su25e1n: / # echo | format
Searching for disks...done
Wow, that is a convoluted way to create a simple mirror(its not raid5 mirrored).. Why has it been setup this way ?

How did you go with your didk replacement, I hope it all went well.

If I was you I would fix that config aswell.

d102, d104 and d106 are soft partitions
d103 is a concat of these soft partitions

d112, d114 and d116 are soft partitions
d113 is a concat of these soft partitions

d100 is a mirror of d103 and d113

A better layout would be.

d100 -m d103 d113 1
d103 1 1 c0t11d0s0
d113 1 1 c0t12d0s0
Tornado
 

10 More Discussions You Might Find Interesting

1. Solaris

Disk Replacement SVM

Hello, Can someone advise the proper procedure for replacing a mirrored disk in SVM. I have checked the docs and various websites but the procedure seems to vary. This is what I would do... 1. Remove the db replicas from the bad disk. 2. Detach it from the mirror 3. Clear it with... (4 Replies)
Discussion started by: Actuator
4 Replies

2. Solaris

Removing Disk from SVM

Hi All, I have to remove the disk from SVM. Kindly guide me or suggest me some link where in I can steps to remove SVM from Solaris 10 .Also I have one metaset which require deletion. Thanks in anticipation! (10 Replies)
Discussion started by: kumarmani
10 Replies

3. Solaris

Disk space missing under SVM

Hi Gurus, I've got an issue here: (1) Hardware: Sun NetraT1, (2) OS: Solaris 10, (3) SVM metastat shows /var having 12 GB. df shows /var having 4 GB. Real space for /var is about 4 GB since I can't move a big file to it. How is 8 GB space missing? Does /var/run swap need to account? Can I... (5 Replies)
Discussion started by: aixlover
5 Replies

4. Solaris

Root Disk mirroring in SVM

Dear All, Please help me to configure root mirroring using SVM in Solaris 9. Thanks and Regards, Lakkireddy BR (3 Replies)
Discussion started by: lbreddy
3 Replies

5. Solaris

Replacing a hard disk (SVM) with a soft partition?

The following is the summarry:- 1) Four disks in server ie (c1t0d0. c1t1d0, c1t2d0, c1t3d0). c1t2d0 is the disk to be replaced. c1t0d0 and c1t2d0 are mirrors. c1t1d0 and c1t3d0 are mirrors. Metadb to be deleted is in c1t2d0s7 a) Mirror d35 has 2 submirrors d38 and d39 d38 is a stripe... (0 Replies)
Discussion started by: aji1729
0 Replies

6. Solaris

Root disk mirroring in SVM

I tried doing rootdisk mirroring in my local host , i added a new Ide disk in my system and copied the prtvtoc from root disk to the newly added disk, and then when i tried to add database replicas on both the disks, it was added for boot disk but for the newly added disk i gave the error, which... (6 Replies)
Discussion started by: Laxxi
6 Replies

7. Solaris

Replacing a Disk in a ODS/SVM Mirror

Hi All BAsed on the below I would like to verifu two things (1) The udnerlying mirroris for '/mnt' na dit onlcy contaisne 1 sub-mirror, with one sliceon is one disk and hence, data loss on the mount point (the mount point, '/mnt' is backed up) (2) the Procedure for renewal # df -kh /mnt... (2 Replies)
Discussion started by: stevie_velvet
2 Replies

8. Solaris

Replacing a failed disk using SVM

Hi Please can you help me on replacing or removing a faulty disk drive on a SUN NETRA X4250server with 4 internal drives only. the format comand show me the following: format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c0t0d0 <drive type unknown> ... (9 Replies)
Discussion started by: fretagi
9 Replies

9. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

10. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies
CCDCONFIG(8)						    BSD System Manager's Manual 					      CCDCONFIG(8)

NAME
ccdconfig -- configuration utility for the concatenated disk driver SYNOPSIS
ccdconfig [-cv] ccd ileave [flags] dev ... ccdconfig -C [-v] [-f config_file] ccdconfig -u [-v] ccd ... ccdconfig -U [-v] [-f config_file] ccdconfig -g [ccd ...] DESCRIPTION
The ccdconfig utility is used to dynamically configure and unconfigure concatenated disk devices, or ccds. For more information about the ccd, see ccd(4). The options are as follows: -c Configure a ccd. This is the default behavior of ccdconfig. -C Configure all ccd devices listed in the ccd configuration file. -f config_file When configuring or unconfiguring all devices, read the file config_file instead of the default /etc/ccd.conf. -g Dump the current ccd configuration in a format suitable for use as the ccd configuration file. If no arguments are specified, every configured ccd is dumped. Otherwise, the configuration of each listed ccd is dumped. -u Unconfigure a ccd. -U Unconfigure all ccd devices listed the ccd configuration file. -v Cause ccdconfig to be verbose. A ccd is described on the command line and in the ccd configuration file by the name of the ccd, the interleave factor, the ccd configuration flags, and a list of one or more devices. The flags may be represented as a decimal number, a hexadecimal number, a comma-separated list of strings, or the word ``none''. The flags are as follows: CCDF_UNIFORM 0x02 Use uniform interleave CCDF_MIRROR 0x04 Support mirroring CCDF_NO_OFFSET 0x08 Do not use an offset CCDF_LINUX 0x0A Linux md(4) compatibility The format in the configuration file appears exactly as if it were entered on the command line. Note that on the command line and in the configuration file, the flags argument is optional. # # /etc/ccd.conf # Configuration file for concatenated disk devices # # ccd ileave flags component devices ccd0 16 none /dev/da2s1 /dev/da3s1 The component devices need to name partitions of type FS_BSDFFS (or ``4.2BSD'' as shown by disklabel(8)). If you want to use the Linux md(4) compatibility mode, please be sure to read the notes in ccd(4). FILES
/etc/ccd.conf default ccd configuration file EXAMPLES
A number of ccdconfig examples are shown below. The arguments passed to ccdconfig are exactly the same as you might place in the /etc/ccd.conf configuration file. The first example creates a 4-disk stripe out of four scsi disk partitions. The stripe uses a 64 sector interleave. The second example is an example of a complex stripe/mirror combination. It reads as a two disk stripe of da4 and da5 which is mirrored to a two disk stripe of da6 and da7. The last example is a simple mirror. The 2nd slice of /dev/da8 is mirrored with the 3rd slice of /dev/da9 and assigned to ccd0. # ccdconfig ccd0 64 none /dev/da0s1 /dev/da1s1 /dev/da2s1 /dev/da3s1 # ccdconfig ccd0 128 CCDF_MIRROR /dev/da4 /dev/da5 /dev/da6 /dev/da7 # ccdconfig ccd0 128 CCDF_MIRROR /dev/da8s2 /dev/da9s3 The following are matching commands in Linux and FreeBSD to create a RAID-0 in Linux and read it from FreeBSD. # Create a RAID-0 on Linux: mdadm --create --chunk=32 --level=0 --raid-devices=2 /dev/md0 /dev/hda1 /dev/hdb1 # Make the RAID-0 just created available on FreeBSD: ccdconfig -c /dev/ccd0 32 linux /dev/ada0s1 /dev/ada0s2 When you create a new ccd disk you generally want to fdisk(8) and disklabel(8) it before doing anything else. Once you create the initial label you can edit it, adding additional partitions. The label itself takes up the first 16 sectors of the ccd disk. If all you are doing is creating file systems with newfs, you do not have to worry about this as newfs will skip the label area. However, if you intend to dd(1) to or from a ccd partition it is usually a good idea to construct the partition such that it does not overlap the label area. For example, if you have A ccd disk with 10000 sectors you might create a 'd' partition with offset 16 and size 9984. # disklabel ccd0 > /tmp/disklabel.ccd0 # disklabel -Rr ccd0 /tmp/disklabel.ccd0 # disklabel -e ccd0 The disklabeling of a ccd disk is usually a one-time affair. If you reboot the machine and reconfigure the ccd disk, the disklabel you had created before will still be there and not require reinitialization. Beware that changing any ccd parameters: interleave, flags, or the device list making up the ccd disk, will usually destroy any prior data on that ccd disk. If this occurs it is usually a good idea to reini- tialize the label before [re]constructing your ccd disk. RECOVERY
An error on a ccd disk is usually unrecoverable unless you are using the mirroring option. But mirroring has its own perils: It assumes that both copies of the data at any given sector are the same. This holds true until a write error occurs or until you replace either side of the mirror. This is a poor-man's mirroring implementation. It works well enough that if you begin to get disk errors you should be able to backup the ccd disk, replace the broken hardware, and then regenerate the ccd disk. If you need more than this you should look into external hardware RAID SCSI boxes, RAID controllers (see GENERIC), or software RAID systems such as geom(8) and gvinum(8). SEE ALSO
dd(1), ccd(4), disklabel(8), fdisk(8), gvinum(8), rc(8) HISTORY
The ccdconfig utility first appeared in NetBSD 1.0A. BUGS
The initial disklabel returned by ccd(4) specifies only 3 partitions. One needs to change the number of partitions to 8 using ``disklabel -e'' to get the usual BSD expectations. BSD
October 1, 2013 BSD
All times are GMT -4. The time now is 02:26 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy