04-12-2007
The driver may not be built into to operating system. You will have to get a driver for the nic first and install it, then run netconfig to install and configure.
Or you may have to go out and buy a card that has an SCO driver with it, and disable the built in card in the CMOS
10 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
The Lan card in one of our UIII WS's seem doesn't work,so with ping command i can not see any of the machines in LAN and with some other tests i'm sure it's not OK.
I tried to use the second card on PCI port ,but the replaced card was one of the ordinary card for PC's ...by the way after... (1 Reply)
Discussion started by: nikk
1 Replies
2. Cybersecurity
what is lan card autonegotiation ?
how to enable and disable this feature? (2 Replies)
Discussion started by: nabil_boussetta
2 Replies
3. SCO
Dear all
Im facing one problem in SCO 5.0.5 , its that in the server there are three LAN cards INTEL PRO 100 series but when we configure all the three cards then LAN stops working . self ping is possible but no one can ping the server. If we remove driver of any one card LAN starts working.
Is... (1 Reply)
Discussion started by: ccvyas
1 Replies
4. UNIX for Dummies Questions & Answers
I have an E420 server that has a TPE Slot / NIC installed.
However there is no interface file installed eg /etc/hostname.hme0 or equivalent.
I have placed a private ip entry int the hosts file to accompany the loop back entry i.e.
127.0.0.1 localhost
172.16.0.10 loghost se420
... (2 Replies)
Discussion started by: jimthompson
2 Replies
5. Programming
Please tell me API in Solaris / Linux / UNIX to get status information of LAN card. (1 Reply)
Discussion started by: mansoorulhaq
1 Replies
6. Linux
Hi.
I have a lan card installed on my server. I want to check the duplex speed of it. How can I check it?
Help is appreciated.
Thank you. (3 Replies)
Discussion started by: Amol21
3 Replies
7. Solaris
Hi,
I've recently moved my pci LAN card from Slot2 Slot5 on my sun x4270_m2 server (solaris 10).
I've done the touch / reconfigure and devfsadm, however my issue is that im able to configure the e1000g7 port with an ip address (192.168.0.1) but if i plug my laptop (set with static ip... (7 Replies)
Discussion started by: kerrygold
7 Replies
8. Linux
Hi,
I have this problem on RHEL box. I am using two NIC's of same model and make (Intel 82557) in the adjacent PCI slots . I am using each one for different subnet and have assigned them ipaddresses and gateways of respective subnets . While one is O.K. connecting to its ... (5 Replies)
Discussion started by: dextergenious
5 Replies
9. Red Hat
Dear Expert,
I 've installed Redhat linux AS3, My machine having Inbuild network card (Intel(R) 82566DM-2 Gigabit Network Connection).
I've downloaded e1000e-2.3.2 from Intel site, but its not working for my machine. I'm unable to configure the Network.
ifconfig eth0 xx.xx.xx.xx netmask... (0 Replies)
Discussion started by: Mohammed Faiz
0 Replies
10. Red Hat
we have red hat 6 linux box
There are two lan card
one lan card eth0 have ip 10.82.190.31/24 GW 10.82.190.254
2th lan card eth1 have ip 10.82.188.33/24 GW 10.82.188.254
I have below route ... I use two route table
root@xxx# netstat -rn
Kernel IP routing table
Destination Gateway ... (5 Replies)
Discussion started by: chuikingman
5 Replies
LEARN ABOUT DEBIAN
piv-tool
PIV-TOOL(1) OpenSC tools PIV-TOOL(1)
NAME
piv-tool - smart card utility for HSPD-12 PIV cards
SYNOPSIS
piv-tool [OPTIONS]
The piv-tool utility can be used from the command line to perform miscellaneous smart card operations on a HSPD-12 PIV smart card as
defined in NIST 800-73-3. It is intened for use with test cards only. It can be used to load objects, and generate key pairs, as well as
send arbitrary APDU commands to a card after having authenticated to the card using the card key provided by the card vendor.
OPTIONS
--serial
Print the derived card serial number from the CHUID object if any. output is in hex byte format.
--name, -n
Print the name of the inserted card (driver)
--admin argument, -A arguement
Authenticate to the card using a 2DES or 3DES key. An arguement {A|M}:{ref}:{alg} is required, were A uses "EXTERNAL AUTHENTICATION"
and M uses "MUTUAL AUTHENTICATION". ref is normally 9B, and alg is 03 for 3DES. The key is provided by card vendor, and the environment
variable PIV_EXT_AUTH_KEY must point to a text file with the key in the format:
XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX:XX
--genkeyargument, -G argument
Generate a key pair on the card and output the public key. An argument {ref}:{alg} is required, where ref is 9A, 9C, 9D or 9E and alg
is 06, 07, 11 or 14 for RSA 1024, RSA 2048, ECC 256 or ECC 384.
--object ContainerID, -O ContainerID
Load an object on to the card. The ContainerID is defined in NIST 800-73-n without leading 0x. Example: CHUID object is 3000
--cert ref, -s ref
Load a certificate on to the card. ref is 9A, 9C, 9D or 9E
--compresscert ref, -Z ref
Load a certificate that has been gziped on to the card. ref is 9A, 9C, 9D or 9E
--out file, -o file
Output file for any operation that produces output.
--in file, -i file
Input file for any operation that requires an input file.
--key-slots-discovery file
Print properties of the key slots. Needs 'admin' authentication.
--send-apdu apdu, -s apdu
Sends an arbitrary APDU to the card in the format AA:BB:CC:DD:EE:FF... This option may be repeated.
--reader, -r num
Use the given reader number. The default is 0, the first reader in the system.
--card-driver driver, -c driver
Use the given card driver. The default is auto-detected.
--wait, -w
Wait for a card to be inserted
--verbose, -v
Causes piv-tool to be more verbose. Specify this flag several times to enable debug output in the opensc library.
SEE ALSO
opensc-tool(1)
opensc 06/03/2012 PIV-TOOL(1)