Sponsored Content
Full Discussion: Autosys Email Alarms
Top Forums UNIX for Dummies Questions & Answers Autosys Email Alarms Post 302110546 by rpiller on Tuesday 13th of March 2007 03:53:35 PM
Old 03-13-2007
Here is what I did. For us the autosys db is an oracle db. there is a table called Alarms. One of the fields (status or something) will be 43 if it's an active alarm (hasn't been taken care of). So basically I have a script read this db for 43's and just email what is in there.
 

10 More Discussions You Might Find Interesting

1. Solaris

Alarms/Alerts

Is there a imbedded command (Solaris v8 ksh) that will send an administrative alert/alarm. Or is it just triggering a mail message via shell script? If no, is there a good open-source code someone knows about? Thanks so much in advance for any replies. ...Gozer13 (3 Replies)
Discussion started by: gozer13
3 Replies

2. Shell Programming and Scripting

alarms

Hi I have been trying to set up alarms on my Solaris box (Sun OS 5.8) The objective is to present the user an audible alarm every hour or so. I have so far done this: #!/bin/sh val=1 while do printf "\a" val=`expr $val + 1` done I have put this in my crontab to run hourly.... (2 Replies)
Discussion started by: run_time_error
2 Replies

3. UNIX for Advanced & Expert Users

Documentation and books on Autosys Job Control Tool from Autosys

My project uses Autosys. I am new to this product and I don't know where to start from. Q1. Please provide me the link where I can get Autosys documentation Q2. Please refer a good book on Autosys. (Beginner/Intermediate Level) (0 Replies)
Discussion started by: gram77
0 Replies

4. Infrastructure Monitoring

Sun Solaris 9 Traps Contain Multiple Alarms

Hi all, I have a Sun Solaris 9 box which acts as a firewall. Sometimes if multiple actions which cause snmp traps occur very close together, a single snmp trap that is sent containing the text for multiple alarms. I would like to prevent that and have a trap sent for each action which would... (0 Replies)
Discussion started by: g0ld2k
0 Replies

5. Solaris

lp serverlist alarms in messages

Hello, I have been receiving following alarms in /var/adm/messages dtcp: WARNING DB (db_tcp.c,363) db_alloc_connid: lp && lp->serverlist error for service 20 It seems like this message is related to LP print service. Since I am not using any print service, is there any way to switch it... (2 Replies)
Discussion started by: aalishan
2 Replies

6. UNIX for Dummies Questions & Answers

Autosys: How to change a machine name in Autosys JIL.

All the autosys jobs are on server-1 and server-1 has been crashed due to some reason, Now I have to run 5 autosys jobs on server-2 (failover server) which are on server 1. How to do with Autosys command (which command needs to fired on JIL) (0 Replies)
Discussion started by: tp2115
0 Replies

7. Solaris

Hardware Alarms on HP-ux Solarisx86

Hi I am trying to configure the Hardware alarms on HP server. I have refer to "HP ProLiant Health Monitor User Guide" and installed HPQacucli-3.5.0-solaris10-i386 HPQhealth-4.4.0-solaris10-i386 HPQhma-5.7.0-solaris10-i386 HPQilo-1.4.5-solaris10-i386 HPQsmh-5.5.0-solaris10-i386 ... (2 Replies)
Discussion started by: anand87
2 Replies

8. Solaris

Strange power supply units alarms!!!

Hi folks, I encountered this alarms on a solaris server: 04/21/12 23:17:55 MNP-PGW-A_bge3 mnp 231748 Power Supply Unit 0 is faulty 04/21/12 23:17:55 MNP-PGW-A_bge3 mnp 231748 Power Supply Unit 1 is faulty 04/21/12 23:18:26 MNP-PGW-A_bge3 mnp 231822 Power Supply Unit 0 is faulty:CLEAR... (0 Replies)
Discussion started by: kimurayuki
0 Replies

9. Solaris

Ftpd alarms

Hi, I am facing following alarms in var/adm/messages after an interval of 10 mins. I dont know what the impact is and how can i fix it. Can anyone help please? Dec 4 07:50:03 hxcsvc-a01 ftpd: open_module: stat(/usr/lib/security/pam_unix_session.so.1) failed: No such file or directory Dec ... (4 Replies)
Discussion started by: sni_engineer
4 Replies

10. Solaris

Sudden Service Busy Alarms

Hi, I am getting service busy alarms on my machines which are using MongoDB every now and then. When the service busy alarm appears, I get the following errors on my mongo router logs. Tue Apr 7 08:01:08.445 dbclient_rs nodes.ok = true hxcslc-b05:27014 Tue Apr 7 08:01:08.445 dbclient_rs... (0 Replies)
Discussion started by: sni_engineer
0 Replies
ALARM(3)						   BSD Library Functions Manual 						  ALARM(3)

NAME
alarm -- set signal timer alarm LIBRARY
Standard C Library (libc, -lc) SYNOPSIS
#include <unistd.h> unsigned int alarm(unsigned int seconds); DESCRIPTION
This interface is made obsolete by setitimer(2). The alarm() function sets a timer to deliver the signal SIGALRM to the calling process after the specified number of seconds. If an alarm has already been set with alarm() but has not been delivered, another call to alarm() will supersede the prior call. The request alarm(0) voids the current alarm and the signal SIGALRM will not be delivered. Due to setitimer(2) restriction the maximum number of seconds allowed is 100000000. RETURN VALUES
The return value of alarm() is the amount of time left on the timer from a previous call to alarm(). If no alarm is currently set, the return value is 0. SEE ALSO
setitimer(2), sigaction(2), sigsuspend(2), signal(3), sleep(3), ualarm(3), usleep(3) HISTORY
An alarm() function appeared in Version 7 AT&T UNIX. BSD
April 19, 1994 BSD
All times are GMT -4. The time now is 10:29 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy