Sponsored Content
Operating Systems Solaris Faulty PSU - but its still working !?! Post 302092803 by hcclnoodles on Thursday 12th of October 2006 08:16:31 AM
Old 10-12-2006
Faulty PSU - but its still working !?!

Hello

We have a power supply in an x4100 (x86) and it seems to be faulty but it is still working!?! (this box only has one PSU). We are getting Orange flashing warning light on the front of the box and the LED labelled “rear PSu” is solid orange ...We don't seem to have had any syslog error messages generated at all on this so ive run ipmitool to see if it can give me some info.

./ipmitool chassis status
System Power : on
Power Overload : false
Power Interlock : inactive
Main Power Fault : true
Power Control Fault : false
Power Restore Policy : always-off
Last Power Event :
Chassis Intrusion : inactive
Front-Panel Lockout : inactive
Drive Fault : false
Cooling/Fan Fault : false



./ipmitool sunoem led get all
sys.psfail.led | ON
sys.tempfail.led | OFF
sys.fanfail.led | OFF
bp.power.led | ON
bp.locate.led | OFF
bp.alert.led | SLOW
etc, etc


Can anybody give me an indication whether this unit will need replacing ...or if there are further tests i should perform

(this is an x86 box so prtdiag wont work unfortunately)

Thanks & regards
Gary
 

10 More Discussions You Might Find Interesting

1. Solaris

Input power unavailable for PSU @ PS0

I have a question here about the OS logs (/var/adm/messages) where it should write most alarms. I ran a hardware test by showing the Power Supply redundancy. Removing PS0 while PS1 is still plugged in confirms that the system still operates with no problems. However, when it comes to logging, I... (1 Reply)
Discussion started by: gilberteu
1 Replies

2. Solaris

Replacing a faulty volume

Hi All, I replace a sub-mirror of a mirrored volume by using below command: #metadetach d10(mirror) d11(striped) #metattach d10 d13(other striped) With above process I successfully replaced a faulty volume. I want to knoow if the process I followed is right. Or if not, what... (5 Replies)
Discussion started by: naw_deepak
5 Replies

3. Solaris

/usr/sap/psu file systems full.

Hi Ive been facing a prob today in SAP which is been installed in solaris .the prob is one of my file systems tat is /usr/sap/psu is gettin full.i chkd the file named core which gets generated so i was asked to delete that file after doing tat my file systems space was 90%,but the prob is that... (0 Replies)
Discussion started by: madanmeer
0 Replies

4. Solaris

PSU info M4/5/8/9000

I need to find out PSU info for some M class severs, normally prtdiag -v show's the relevant PS info, however these M classes don't seem to go down to that level !? Anyone any ideas , no physical or console access available at this stage :( thx... (3 Replies)
Discussion started by: itsupplies
3 Replies

5. Solaris

Reset PSU fault

Hi all, I have one Sun Oracle T5220 server with Solaris 10. On the front panel I saw the PSU fault led is steady with an orange color. So I checked the PSUs changed them and checked the "showfaults", "showfru" and some another commands, no problem. On the rear side I don't see any errors... (2 Replies)
Discussion started by: hubatuwang
2 Replies

6. Shell Programming and Scripting

shell script to check if PSU and fan needs to be replaced?

does anyone know any shell script command that can check if PSU and fan needs to be replaced? examples will also be greatly appreciated. thanks! (5 Replies)
Discussion started by: h0ujun
5 Replies

7. Solaris

Is it possible to set a PSU as faulty on Solaris

Hi, I'm trying to generate an alert related to Power Supply Failure. As its difficult to generate such an event, Is it possible to set the status of a Power Supply Unit as "Faulty" Any ideas are welcome and highly appreciated -Thanks (3 Replies)
Discussion started by: justsam
3 Replies

8. Red Hat

Check PSU Status

Hello, We have a cluster and each server have 2 PSU. An alarm should be raised in case of failure so we need to check periodically the PSU status wth a script. The first idea was to check with ipmitool but this take some time to get the data and we face some other issues now due to that... (1 Reply)
Discussion started by: @dagio
1 Replies

9. Solaris

PSU is bad?

Hello, When reviewing the messages log today I noted something odd, so I ran: /usr/lib/osa/bin/healthck -a and the response noted Failed Power Supply. Sure enough the light on the PSU is amber. Uh oh... In an effort to see if I can figure out what kinds of PSU we have, I found a... (2 Replies)
Discussion started by: madEG
2 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
LED(4)							   BSD Kernel Interfaces Manual 						    LED(4)

NAME
led -- API for manipulating LED's, lamps and other annunciators SYNOPSIS
#include <dev/led/led.h> typedef void led_t(void *priv, int onoff); struct cdev * led_create_state(led_t *func, void *priv, char const *name, int state); struct cdev * led_create(led_t *func, void *priv, char const *name); void led_destroy(struct cdev *); DESCRIPTION
The led driver provides generic support for handling LEDs, lamps and other annunciators. The hardware driver must supply a function to turn the annunciator on and off and the device name of the annunciator relative to /dev/led/. The priv argument is passed back to this on/off function and can be used however the hardware driver sees fit. The lamp can be controlled by opening and writing ASCII strings to the /dev/led/bla device. In the following, we will use this special notation to indicate the resulting output of the annunciator: * The annunciator is on for 1/10th second. _ The annunciator is off for 1/10th second. State can be set directly, and since the change happens immediately, it is possible to flash the annunciator with very short periods and syn- chronize it with program events. It should be noted that there is a non-trivial overhead, so this may not be usable for benchmarking or mea- suring short intervals. 0 Turn the annunciator off immediately. 1 Turn the annunciator on immediately. Flashing can be set with a given period. The pattern continues endlessly. f _* f1 _* f2 __** f3 ___*** ... f9 _________********* Three high-level commands are available: d%d Numbers. Each digit is blinked out at 1/10th second, zero as ten pulses. Between digits a one second pause and after the last digit a two second pause after which the sequence is repeated. s%s String. This gives full control over the annunciator. Letters 'A' ... 'J' turn the annunciator on for from 1/10th to one full second. Letters 'a' ... 'j' turn the annunciator off for 1/10th to one full second. Letters 'u' and 'U' turn the annunciator off and on respectively when the next UTC second starts. Unless terminated with a '.', the sequence is immediately repeated. m%s Morse. '.' becomes '_*' '-' becomes '_***' ' ' becomes '__' ' ' becomes '____' The sequence is repeated after a one second pause. FILES
/dev/led/* EXAMPLES
A 'd12' flashes the lamp *__________*_*______________________________ A 'sAaAbBa' flashes *_*__**_ /usr/games/morse -l "Soekris rocks" > /dev/led/error SEE ALSO
morse(6) HISTORY
The led driver first appeared in FreeBSD 5.2. AUTHORS
This software was written by Poul-Henning Kamp <phk@FreeBSD.org>. This manual page was written by Sergey A. Osokin <osa@FreeBSD.org> and Poul-Henning Kamp <phk@FreeBSD.org>. BSD
April 24, 2007 BSD
All times are GMT -4. The time now is 10:16 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy