Thanks guys. This reassures my logic and hopefully the
customer will go with 4 drives instead of two.
But as stated they probably could go with just 2 drives but lose
the true effect of the stripping and increased redundancy.
 

9 More Discussions You Might Find Interesting

1. Solaris

RAID 0+1 Vs RAID 1+0

hi all...sudhansu here............ i need some help.......... what is RAID 0+1 and RAID 1+0.............what is the difference between them................ suppose i have 80 gb disk space,then which RAID level i follow n why......... i need redundancy n maximum storage..........please help (3 Replies)
Discussion started by: sudhansu
3 Replies

2. Solaris

Raid 0

Somebody can help me ! how can i do mirror in sun ver 8 without third party software !!! (3 Replies)
Discussion started by: goldfelda
3 Replies

3. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

4. Solaris

implementing RAID 1 from RAID 5

Dear ALl, I have a RAID 5 volume which is as below d120 r 60GB c1t2d0s5 c1t3d0s5 c1t4d0s5 c1t5d0s5 d7 r 99GB c1t2d0s0 c1t3d0s0 c1t4d0s0 c1t5d0s0 d110 r 99GB c1t2d0s4 c1t3d0s4 c1t4d0s4 c1t5d0s4 d8 r 99GB c1t2d0s1 c1t3d0s1... (2 Replies)
Discussion started by: jegaraman
2 Replies

5. Solaris

Creation of Raid 01 and Raid 10

Hello All, I have read enough of texts on Raid 01 and Raid 10 on solaris :wall: . But no-where found a way to create them using SVM. Some one pls tell me how to do or Post some link if that helps. TIA Curious solarister (1 Reply)
Discussion started by: Solarister
1 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. UNIX for Dummies Questions & Answers

Need help with RAID.

Hi Gurus, Can any one explain me the difference between hardware RAID and s/w RAID. Thanks in Advance. (1 Reply)
Discussion started by: rama krishna
1 Replies

8. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

9. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies
VMSTAT(1)						      General Commands Manual							 VMSTAT(1)

NAME
vmstat - report virtual memory statistics SYNOPSIS
vmstat [ -fsi ] [ drives ] [ interval [ count ] ] DESCRIPTION
Vmstat delves into the system and normally reports certain statistics kept about process, virtual memory, disk, trap and cpu activity. If given a -f argument, it instead reports on the number of forks and vforks since system startup and the number of pages of virtual memory involved in each kind of fork. If given a -s argument, it instead prints the contents of the sum structure, giving the total number of several kinds of paging related events which have occurred since boot. If given a -i argument, it instead reports on the number of inter- rupts taken by each device since system startup. If none of these options are given, vmstat will report in the first line a summary of the virtual memory activity since the system has been booted. If interval is specified, then successive lines are summaries over the last interval seconds. ``vmstat 5'' will print what the system is doing every five seconds; this is a good choice of printing interval since this is how often some of the statistics are sampled in the system; others vary every second, running the output for a while will make it apparent which are recomputed every second. If a count is given, the statistics are repeated count times. The format fields are: Procs: information about numbers of processes in various states. r in run queue b blocked for resources (i/o, paging, etc.) w runnable or short sleeper (< 20 secs) but swapped Memory: information about the usage of virtual and real memory. Virtual pages are considered active if they belong to processes which are running or have run in the last 20 seconds. A ``page'' here is 1024 bytes. avm active virtual pages fre size of the free list Page: information about page faults and paging activity. These are averaged each five seconds, and given in units per second. re page reclaims (simulating reference bits) at pages attached (found in free list) pi pages paged in po pages paged out fr pages freed per second de anticipated short term memory shortfall sr pages scanned by clock algorithm, per-second up/hp/rk/ra: Disk operations per second (this field is system dependent). Typically paging will be split across several of the available drives. The number under each of these is the unit number. Faults: trap/interrupt rate averages per second over last 5 seconds. in (non clock) device interrupts per second sy system calls per second cs cpu context switch rate (switches/sec) Cpu: breakdown of percentage usage of CPU time us user time for normal and low priority processes sy system time id cpu idle If more than 4 disk drives are configured in the system, vmstat displays only the first 4 drives, with priority given to Massbus disk drives (i.e. if both Unibus and Massbus drives are present and the total number of drives exceeds 4, then some number of Unibus drives will not be displayed in favor of the Massbus drives). To force vmstat to display specific drives, their names may be supplied on the command line. FILES
/dev/kmem, /vmunix SEE ALSO
systat(1), iostat(1) The sections starting with ``Interpreting system activity'' in Installing and Operating 4.2bsd. 4th Berkeley Distribution March 15, 1986 VMSTAT(1)