Sponsored Content
Full Discussion: Raid 1+0 ?
Special Forums Hardware Filesystems, Disks and Memory Raid 1+0 ? Post 302073376 by Perderabo on Friday 12th of May 2006 10:52:26 AM
Old 05-12-2006
Yes you need 4 disks at a minimum, but no, the loss of a single disk should not take the shebang down. Not even for raid 0+1. And certainly not for raid 1+0.

With only 2 drives, you really can't do raid 0+1 or raid 1+0, unless you take the view that each drive counts as a striped array with a 72 GB wide stripe. So then you simply mirror the drives and then the loss of one drive is still not a system killer.
 

9 More Discussions You Might Find Interesting

1. Solaris

RAID 0+1 Vs RAID 1+0

hi all...sudhansu here............ i need some help.......... what is RAID 0+1 and RAID 1+0.............what is the difference between them................ suppose i have 80 gb disk space,then which RAID level i follow n why......... i need redundancy n maximum storage..........please help (3 Replies)
Discussion started by: sudhansu
3 Replies

2. Solaris

Raid 0

Somebody can help me ! how can i do mirror in sun ver 8 without third party software !!! (3 Replies)
Discussion started by: goldfelda
3 Replies

3. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

4. Solaris

implementing RAID 1 from RAID 5

Dear ALl, I have a RAID 5 volume which is as below d120 r 60GB c1t2d0s5 c1t3d0s5 c1t4d0s5 c1t5d0s5 d7 r 99GB c1t2d0s0 c1t3d0s0 c1t4d0s0 c1t5d0s0 d110 r 99GB c1t2d0s4 c1t3d0s4 c1t4d0s4 c1t5d0s4 d8 r 99GB c1t2d0s1 c1t3d0s1... (2 Replies)
Discussion started by: jegaraman
2 Replies

5. Solaris

Creation of Raid 01 and Raid 10

Hello All, I have read enough of texts on Raid 01 and Raid 10 on solaris :wall: . But no-where found a way to create them using SVM. Some one pls tell me how to do or Post some link if that helps. TIA Curious solarister (1 Reply)
Discussion started by: Solarister
1 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. UNIX for Dummies Questions & Answers

Need help with RAID.

Hi Gurus, Can any one explain me the difference between hardware RAID and s/w RAID. Thanks in Advance. (1 Reply)
Discussion started by: rama krishna
1 Replies

8. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

9. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies
sautil(1M)																sautil(1M)

NAME
sautil - support utility for the HP SmartArray RAID controller family SYNOPSIS
device_file [-N] device_file [-s] device_file fw_image device_file fw_image physical_drive_id device_file fw_image encl_physical_drive_id device_file device_file device_file device_file logical_drive_number device_file rate device_file device_file device_file device_file [-raw] device_file device_file physical_drive_id [-raw] device_file device_file device_file DESCRIPTION
The command is a support tool for the HP SmartArray RAID Controller Family. This command allows the system administrator to perform tasks such as: 1) Retrieving RAID configuration and status information for the controller, logical drive, physical disk, cache, etc.; 2) Retrieving RAID driver information (driver state, trace log, statistics, etc.); 3) Downloading new revisions of controller or disk firmware; 4) Sending instructions to the firmware (reset controller, scan SCSI bus, etc.); and 5) Recreating the controller device file(s). Prerequisites Some of the options are intended for use by HP support personnel and require detailed knowledge of the RAID SA driver or firmware to inter- pret the output. Security Restrictions requires either the superuser privilege or and privileges. See privileges(5) for more information about privileged access on systems that support fine-grained privileges. Options recognizes the following options and parameters as indicated in the section above. Keyword options are order-dependent, but are not case- sensitive. device_file Most options require a device file parameter, e.g., The device file for a specific RAID SA controller can be determined from the output. When the device file parameter is specified without any options, will display information such as the RAID SA driver state, controller hardware path, firmware revision, capacity expansion and rebuild priority settings, cache status and settings, logical drive configuration and physical drive properties. When the optional argument is specified, persistent device files (see intro(7)) are displayed for logical drives. When the optional argument is specified, a subset of the information is displayed. This option downloads the specified firmware image file (fw_image) to the controller. The image file name is case-sensitive. The firmware download process usually completes within one minute, but could theoretically take up to eight minutes. All I/O to the controller are temporarily halted dur- ing this time. This option downloads the specified firmware image file (fw_image) to physical disk specified by the (physical_drive_id). The image file name is case-sensitive. physical_drive_id To specify the SCSI physical disk. It can be represented as such as: 4:12. Valid channel numbers are between 1 and 4. Valid target numbers are between 0 and 15. To specify the SAS/SATA physical disk. It can be represented as either such as: 2I:1:10 or (wwid), such as: 0x500000e010f16432. This option downloads the specified firmware image file (fw_image) to the storage enclosure processor. This option is supported on SAS Smart Array HBAs only. The image file name is case-sensitive. The firmware download process takes ten to fifteen minutes. All I/O to the controller are temporarily halted during this time. encl_physical_drive_id To specify the storage enclosure processor. It can be represented as either such as: 1E:1:0 or (wwid), such as: 0x500000e010f16432. This option resets the controller. Some situations that may require a controller reset are: 1) OLR was performed and the logical drives on the replacement controller are not detected; 2) a disk enclosure with an existing RAID configuration was hot-added and the logical drives on that enclosure are not detected. This option tells the controller to rescan all SCSI buses. A situation that may require a scan is when a physical disk is hot-inserted into the system's internal drive bay. This option tells the controller to start rebuilding any logical drives that are in state. All logical drives in this state will eventually transition to Heavy I/O to the controller may delay this transition. There is no adverse impact if this option is invoked when no logical drives are in state. This option grants permission to the controller to set the state of the specified failed logical drive (logical_drive_number) to "OK" and to set the states of all failed physical disks that have been replaced via hot-plug exchanges to "OK". WARNING: While this option preserves the RAID configuration (logical drive configurations, controller settings, etc.), data on the failed logical drive may have already been compromised. If more disks have failed than the RAID level can accommo- date, you will need to restore your data from backup media. This option tells the controller to set the SCSI transfer rate to a lower speed than it would normally allow. Valid arguments for the rate field are (and ultra-160 for controllers that support Ultra-320). This option displays statistics counters maintained by the RAID SA "ciss" driver. This option clears the statistics counters maintained by the RAID SA "ciss" driver. This option displays the trace buffer of the RAID SA "ciss" driver. This option displays the firmware error log of the RAID SA controller. When the optional argument is specified, the raw data (in bytes) are displayed. This option clears the firmware error log of the RAID160 SA controller. It is not available for SmartArray 640x controllers. This option displays the error log for the physical disk specified by the (physical_drive_id). When the optional argument is specified, the raw data (in bytes) are displayed. This option displays the RAID SA controller's PCI configuration header. This option allows interactive reading of the RAID SA controller's registers. WARNING: Reading an invalid register may cause a system crash. This option is only available for SAS/SATA. Vital Product Data contains Product Description, Part Number, Engineering Date Code, Serial Number, Miscellaneous Informa- tion, Manufacturing Date Code, EFI Version, Asset Tag, HBA Firmware Version, and WWN. This option runs the RAID SA startup script to recreate the device files (/dev/cissX). Logical Drive State Definitions All physical disks in the logical drive are operational. Some possible causes: 1) Multiple physical disks in a fault-tolerant (RAID 1, 1+0, 5, ADG) logical drive have failed. 2) One or more disks in a RAID 0 logical drive have failed. 3) Cache data loss has occurred. 4) Array expansion was aborted. 5) The logical drive is temporarily disabled because another logical drive on the controller had a missing disk at power-up. Also known as "degraded" state. A physical disk in a fault tolerant logical drive has failed. For RAID 1, 1+0 or 5, data loss may result if a second disk should fail. For RAID ADG, data loss may result if two additional disks should fail. A replacement disk is present, but rebuild hasn't started yet (another logical drive may be currently rebuilding). The logical drive will also return to this state if the rebuild had been aborted due to unrecoverable read errors from another disk. One or more physical disks in this logical drive are being rebuilt. While the logical drive was in a degraded state, the system was powered off and a disk other than the failed disk was replaced. Shut off the system and replace the correct (failed) disk. While the system was off, one or more disks were removed. Note: the other logical drives are held in a temporary "failed" state when this occurs. The data in the logical drive is being reorganized because: 1) Physical disks have been added to the array (capacity expansion). 2) The stripe size is being changed (stripe-size migration). 3) The RAID level is being changed (RAID-level migration). A capacity expansion operation is in progress (or is queued up) that will make room on the disks for this new logical drive. Until room has been made on the physical disks, this newly configured logical drive cannot be read or written. The logical drive is waiting to undergo data reorganization (see above). Possible causes for the delay are a rebuild or expansion operation may already be in progress. Physical Disk State Definitions The physical disk is configured in one or more logical drives and is operational. The physical disk is configured as a spare disk. The physical disk has not been configured in any logical drives. The configured physical disk has failed. RETURN VALUE
returns the following values: Successful completion. Command line syntax error. Incompatible CISS driver API. Failure opening a file. Other error. EXAMPLES
Display RAID subsystem information for the controller Update the firmware on the controller using the firmware image file Update the firmware on the physical disk (SCSI ID "13") connected to channel "2" of controller using the firmware image file located in the current directory: Recreate the device files for all RAID SA controllers in the system: AUTHOR
was developed by HP. FILES
Executable file. Device files. SEE ALSO
saconfig(1M), privileges(5), intro(7). sautil(1M)
All times are GMT -4. The time now is 09:40 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.